Explain the effect of power factor on wattmeter reading in two wattmeter method for power measurement.

1 Answer

Answer :

Effect of P.F. on Reading of Wattmeter in Two Wattmeter Method:

electronics2electrical.com 751 -  .jpg

Related questions

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : In two -wattmeter method of power measurement, if one wattmeter shows negative reading, then the power factor of the circuit is treated as (A) Unity (B) Lagging (C) Leading (D) Zero

Last Answer : Lagging   power   factor.

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : A single phase wattmeter rated for 500 V; 5A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

Last Answer : Answer :

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : Explain the error occurred due to pressure coil inductance of electrodynamometer type wattmeter. How this error is compensated?

Last Answer : For power measurement assume that the pressure coil of wattmeter is purely restitive. Hence current taken by pressure coil Ipc is in phase with voltage across the pressure coil Vpc  ... inductive reactance XL the pressure coil circuit is made purely resistive and the error is eliminated.

Description : State any two disadvantages of one wattmeter method of measurement of 3 phase power.

Last Answer : State any two disadvantages of one wattmeter method of measurement of 3 phase power. Disadvantages of one wattmeter method:- 1. Only used for balanced load 2. It can not be used for ... connection then neutral point must be available 4. Delta connection must be opened to connect current coil.

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a _____________. A. low switchboard wattmeter reading B. reading of 1.0 on the power factor meter C. high switchboard voltmeter reading D. totally darkened switchboard ground-detecting light

Last Answer : Answer: D

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive 

Description : Draw and explain the circuit diagram for measurement of single phase power using dynamometer type wattmeter. 

Last Answer : Circuit diagram for measurement of single phase power using dynamometer type wattmeter: Explanation: It consists of two stationary coils, called current coils and one moving coil, called voltage or ... i.e. power. The meter can be calibrated directly to indicate the power in watts. 

Description : Describe the procedure for the measurement of earth resistance by using earth tester.

Last Answer : Measurement of earth resistance by using earth tester:  It is connected to earth electrode E, whose resistance is to be measured, and the other spike P and R, as shown in the ... , the deflection of the pointer will indicate directly resistance in ohm of the earth electrode under test. 

Description : Describe with suitable example; frequency measurement by Lissajous patterns on CRO. 

Last Answer : * Initially the unknown frequency signal is connected to vertical deflection plates of CRO. * Now switch of the internal sweep generator of the horizontal deflecting system. * A standard source ... explain by following example: Assume horizontal input frequency is 10 kHz for following pattern

Description : The instrument for measurement of flow/ velocity is________. A. Bimetallic. C) Turbine meter. B. Manometer. D) Wattmeter

Last Answer : Turbine meter

Description : A ground on a particular phase of a three-phase low voltage distribution system would be indicated by a _____________. A. high switchboard wattmeter reading B. low switchboard wattmeter reading C. dark or dim switchboard ground detecting light D. bright switchboard ground detecting light

Last Answer : Answer: C

Description : A current-carrying conductor making electrical contact with a wiring conduit will be indicated by a _____________. A. high switchboard wattmeter reading B. totally dark switchboard ground detecting light C. low switchboard wattmeter reading D. all of the above

Last Answer : Answer: B

Description : A current-carrying conductor makes accidental contact with a wiring conduit. This will be indicated by a _____________. A. low switchboard wattmeter reading B. high switchboard wattmeter reading C. darkened switchboard ground detecting lamp D. darkened switchboard synchronizing lamps

Last Answer : Answer: C

Description : The reading of wattmeter in no load test of induction motor gives : (A) Friction and windage loss (B) Copper losses on no load in the stator (C) Core losses (D) Sum of all losses

Last Answer : A

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : A portable hand-held and is very handy for determining the power consumption and power factor of individual motors and other inductive devices. a) Voltmeter and wattmeter. b) Wattmeter and power factor meter. c) Light meter and flash meter.

Last Answer : Voltmeter and wattmeter.

Description : Consider the following statements  1) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil ii) The compensating coil of a low power factor wattmeter compensates the effect ... C) Both (i) and (ii) are true D) Both (i) and (ii) are false

Last Answer : A

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Description : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is (A) zero (B) 0.5 (C) between zero and 0.5 (D) between 0.5 and unity

Last Answer : The power consumed by a balanced 3-ph load is measured by two-wattmeter method. The meter readings are 8 kW and 4 kW. The power factor of the load is between 0.5 and unity

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Description : Compare analog instrument to digital instrument on the basis of accuracy, resolution, power required and portability. 

Last Answer : Comparison between Analog instruments & Digital instruments: 

Description : Explain with neat sketch the construction and working principle of megger.

Last Answer : Megger: Construction of Megger : Two coils: the current coil and pressure coil are mounted at an angle on the same spindle and form the part of the moving system. These coils are ... force produces a torque that is used to deflect the pointer of the device which gives some reading.

Description : Explain the calibration of single phase electronic energy meter using direct loading.

Last Answer : Calibration of Single-phase Electronic Energy Meter by Direct Loading Method: The following figure shows the arrangement of calibration for single phase electronic energy meter. A phase shifter is connected for ... are taken for different values of current at different power factors. 

Description : Explain with neat sketch; the construction and working principle of Repulsion type moving iron instrument.

Last Answer : Repulsion Type Moving Iron Instrument: Construction: It consist of fixed cylinder hollow coil which carries operating current inside the coil there are two soft iron pieces. One of which is ... magnetized with same polarity a repulsive force act on them and moving iron piece gets deflected. 

Description : Explain with neat sketch, the working of full wave rectifier voltmeter.

Last Answer : Full Wave Rectifier Type Voltmeter: Working of full wave rectifier type A. C. Voltmeter Referring to the circuit diagram, for rectification, a full wave bridge circuit (ABCD) is used. Input ... current passing through meter is given as, which causes full scale deflection of the meter.

Description : State the purpose of calibration of measuring instruments. Explain the procedure of calibration of D.C. voltmeter by using D.C. potentiometer.

Last Answer : Purpose of calibration : Calibration is the process of evaluating and adjusting the precision and accuracy of measuring equipment. Proper calibration of an instrument allows people to have a safe ... calibration curve can be drawn by plotting the percentage error against the measured voltages. 

Description : Merits of two wattmeter method

Last Answer : Advantages of Two Wattmeter Method for 3-Phase Power Measurement: 1) It is used for balanced as well as unbalanced load. 2) For the star type load, it is not necessary to ... reactive volt-amperes for balanced loads also. 7) The circuit connections are independent of load connection.

Description : List one advantage and one disadvantage of one wattmeter method. 

Last Answer : Advantages:  1) Only one wattmeter is used.  2) Less number of connections.  3) Cost required is less.  Disadvantages:  1) Used only for 3- Φ balanced load and not for ... be accessible for connecting the Pressure coil.  3) Delta connection must be opened to connect current coil. 

Description : Draw block diagram of function generator and state the function of each block. 

Last Answer : Block Diagram of Function Generator: OR Working of Function Generator : This instrument can deliver sine, triangular & square waves with frequency range of 0.01 Hz to ... output voltage reaches a predetermined level on the negative slope of the integrator's output voltage. 

Description : Draw the block diagram of tri-vector meter. State the various measurements possible from tri-vector meter.

Last Answer : Various measurements possible from tri-vector meter are: Tri-vector meter is a measuring instrument which measures the kWh, kVArh, the kVAh of a power line. Tri-vector meter is an energy meter ... of supply such as voltage, current, power factor, active load, reactive load, apparent load etc.

Description : Describe with block diagram the working of digital frequency meter.

Last Answer : Digital frequency meter: Amplifier: The signal whose frequency is to be measured is first amplified and supplied to the schmitt trigger. Schmitt Trigger: The schmitt trigger convert ... count displayed on counter  t = time interval between start and stop condition of the gate 

Description : Describe with block diagram; the principle of operation of digital storage oscilloscope.

Last Answer : The block diagram of DSO is shown above. Sampling rate may be as high as 1,00,000 samples per sencod. For such high sampling rates, a fast conversion ADC is requried. Flash ADC ... particular signal in the memory then overwritting should be stopped.This obtained by using Hold and Save button.

Description :  Draw a neat labeled block diagram of 3-phase Electronic Energy meter.

Last Answer : Labeled diagram of 3-phase electronic energy meter:

Description : Describe with block diagram; the construction of single phase electronic energy meter. 

Last Answer : Construction of Single Phase Electronic Energy Meter: 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the ... The ADC converts the square wave frequency analog output to display the energy in Watt-hour.

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : List the types of systematic errors and state the reasons due to which these errors occur.

Last Answer : Systematic Error: i) Instrumental Error: These errors are caused due to the mechanical structure of measuring instrument such as: a) Inherent shortcomings of instruments: Instrument may ... or electrostatic fields. iii) Observational Error: Parallax errors, incorrect multiplying factor.

Description : State the advantages of electronic energy meter. 

Last Answer : Advantages of Electronic Energy Meter: 1) Low cost. 2) High accuracy. 3) More flexibility. 4) High sensitivity 5) No frictional losses. 6) Less loading effect. 7) High frequency ... for external adjustment. 11) Low load, full load, power factor and creeping adjustments are not required.

Description : List the errors occuring in single phase electronic energy meter.

Last Answer : Errors in Single Phase Electronic Energy Meter: 1) Error due to wrong sensor opeartion. 2) Error due to temperature. 3) Error due to wrong CT opeartion. 4) Error due to wrong PT opeartion. 5 ... of scaling network. 6) Error due to wrong ADC opeartion. 7) Error due to wrong Display.