Define Pole Pitch?

1 Answer

Answer :

The distance between the centers of two adjacent poles is called pole pitch. One pole pitch is equals to 180 electrical degrees. It is also defined as the number of slots per pole.

Related questions

Description : Define pole pitch.

Last Answer : It is centre to centre distance between two adjacent poles. Two poles are responsible for 360 degree electrical of induced emf so one pole is responsible for 180 degree electrical of induced emf. Hence 180 degree electrical is called 1 pole pitch.

Description : When the two coil sides forming a coil are spaced exactly one pole pitch apart they are said to be of (a) short pitch (b) full pitch (c) either of the above (d) none of the above

Last Answer : (b) full pitch

Description : A pole pitch in electrical machine is: (1) Equal to 180° electrical (2) Equal to 180° mechanical (3) Less than 180° electrical (4) Greater Than 180° electrical

Last Answer : A pole pitch in electrical machine is: Equal to 180° electrical

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : What is the pitch factor of a 4 pole alternator having 36 slots and a coil span of 1 to 8?  (A) 140° (B) 80° (C) 20° (D) 40°

Last Answer : C

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Description : Define pitch factor or coil span factor.

Last Answer : The pitch factor is defined as the ratio of vector sum of emf induced in a coil to arithmetic sum of emf induced in the coil OR It is the ratio of resultant emf induced when coil is short pitch to the resultant emf induced when the coil is full pitched.

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : A faulty 'function generator' shown in the illustration may prevent _____________. EL-0095 A. proper pitch control from both the 'bridge' and 'engine room thrust levers' B. the 'split potentiometer ... control pitch C. the pitch meter from indicating accurately D. relays #2 and/or #3 from energizing

Last Answer : Answer: A

Description : Vessel pitch can be controlled by either the 'bridge or engine room thrust lever' shown in the illustration; but only with one engine on the line whether in 'cruise or maneuver' mode. The cause is most likely a faulty relay _____________. EL-0095 A. #1 B. #2 C. #3 D. #4

Last Answer : Answer: D

Description : If Relay #5 changed contact position grounding the 'auto' input to the 'pitch controller module', pitch control would be effected by the _________________. EL-0095 A. pitch feedback potentiometer B. Engine room thrust split potentiometer C. Engine room thrust lever only D. Bridge thrust lever only

Last Answer : Answer: B

Description : In the pitch control diagram shown in the illustration, what are the present plant operating conditions? EL-0095 A. One engine is on the line, cruise mode is selected and the engine room is in control. ... . D. Both engines are on line, maneuvering mode is selected and the engine room is in control.

Last Answer : Answer: D

Description : As shown in the two illustrations for 'pitch control' and engine speed control', when the plant is in 'AUTO / CRUISE' propeller pitch is controlled by ___________. EL-0095 A. the 'trim potentiometer' and ... and speed by its 'trim pot'. D. either 'thrust lever' and speed by the 'trim potentiometer'

Last Answer : Answer: D

Description : As shown in the illustration, a 'pitch cutback' feature is incorporated in the system. This circuit reduces pitch amount to prevent engine overload when it senses ____________. EL-0095 A. pitch error of ... servo' C. excessive propeller speed or fuel to either engine D. only one engine on the line

Last Answer : Answer: C

Description : The 'pitch controller module' shown in the illustration is fed the actual pitch position of the propeller from the _____________. EL-0095 A. 'pitch meter' B. 'pitch feedback potentiometer' C. #5 relay position D. pitch error signal

Last Answer : Answer: B

Description : As shown in the illustration, the circuit which 'shapes' the linear output of the thrust lever so that the steady-state ship speed is linear with respect to that lever's setting is the _____________. EL-0095 A. 'pitch controller' B. 'error amplifier' C. 'function generator' D. 'servo amplifier'

Last Answer : Answer: C

Description : Why is short pitch winding preferred over full-pitch winding ?

Last Answer : Advantages · Sinusoidal waveform: Waveform of the emf can be approximately made to a sine wave and distorting harmonics can be reduced or totally eliminated. · Economical :Conductor ... harmonics are eliminated, the eddy current and hysteresis losses are reduced which increases overall efficiency

Description : What is full pitch winding?

Last Answer : If coil pitch is equal to pole pitch it is called full pitch winding

Description : What is short pitch winding?

Last Answer : If coil pitch is equal to less than pole pitch it is called short pitch winding

Description : Harmonics are eliminated by using a) Skewing of rotor b) Distribution winding c) Short pitch winding d) All of the above

Last Answer : Ans: All of the above

Description : Define Diameteral Pitch?

Last Answer : Diameteral pitch is the ratio between the number of teeth of a gear and the pitch circle diameter.

Description : Define the term ‘Landing and Pitch’ used in stair.

Last Answer : Landing: - It is flat platform at the top or bottom of a flight between the floors. Pitch: - It is the angle which the line of nosing of the stair makes with floor.

Description : Which of the following statements is/are true regarding requirements for receptacle outlets aboard vessels? A. Each receptacle outlet operating at 100 volts or more must have a grounding pole. B. Outlets ... machinery with a portable light having a 50 foot flexible cord. D. All of the above.

Last Answer : Answer: A

Description : As shown in the illustration, part 'X' of the diagram is known as a/an _____________. EL-0052 A. commutator B. interpole C. starting pole D. auxiliary pole

Last Answer : Answer: B

Description : An open shunt field in a direct current machine may be located by connecting the field circuit to an external power source, equal to the rated field voltage or less, and tested with a voltmeter from ... C. any suitable ground to any available line lead D. any field pole to each field coil lead

Last Answer : Answer: A

Description : A four pole turbogenerator is used in conjunction with a 160 pole propulsion motor. If the generator is turning at 3,200 RPM, what is the current speed of the propeller? A. 40 RPM B. 60 RPM C. 80 RPM D. 100 RPM

Last Answer : Answer: C

Description : What will be the frequency of a three-phase, six pole, AC generator operating at 1800 revolutions per minute? A. 60 hertz B. 90 hertz C. 120 hertz D. 180 hertz

Last Answer : Answer: B

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : Uneven wear of the commutator surface on a direct current propulsion motor can be caused by _____________. A. rapid change in load B. excessive operation at light load C. incorrect brush staggering D. unequal pole spacing

Last Answer : Answer: C

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : Which of the listed motors will operate at the highest RPM, assuming that each operates at the same frequency? A. A four-pole synchronous motor under normal load. B. A four-pole induction motor under ... A six-pole synchronous motor under normal load. D. A six-pole induction motor under full load.

Last Answer : Answer: A

Description : A four-pole 60-hertz induction motor has a synchronous speed of 1800 RPM and a slip of 4 percent at full load. What will be its full load speed? A. 1728.0 RPM B. 1730.7 RPM C. 1800.0 RPM D. 1872.0 RPM

Last Answer : Answer: A

Description : A four-pole, 60 cycle, squirrel-cage motor has a full load speed of 1725 RPM. What will be the percent of slip at full load? A. 4.16 B. 4.34 C. 95.66 D. 95.84

Last Answer : Answer: A

Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18

Last Answer : Answer: C

Description : The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed? A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

Last Answer : Answer: C

Description : As shown in the illustration, 'B' is a ____________. EL-0058 A. single-pole, double-throw switch B. double-pole, single-throw switch C. double-pole, double-throw switch D. circuit breaker

Last Answer : Answer: C

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : A four-pole induction motor, operating on three-phase 60 cycle current will operate at approximately ___________. A. 850 RPM B. 1,150 RPM C. 1,750 RPM D. 3,550 RPM

Last Answer : Answer: C

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : A three-phase, squirrel cage, induction motor will run hot due to a/an ______________. A. improper brush position B. reversed commutating pole C. shorted stator D. high power factor

Last Answer : Answer: C

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : A megohmmeter can be used to test for _____________. A. an open field coil B. a shorted field pole C. undercut mica D. reversed polarity

Last Answer : Answer: A

Description : In the construction of D.C. motors, parts of both the series and shunt fields are wound on the _____________. A. opposite main pole B. rotor core C. interpole D. same main pole

Last Answer : Answer: D

Description : Relative to the direction of rotation, a D.C. motor commutating pole has the same polarity as the _____________. A. main pole following B. interpole following C. main pole preceding D. interpole preceding

Last Answer : Answer: C

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C

Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch

Last Answer : Answer: A

Description : Magnet chatter or 'pumping' occurring in a magnetic contactor can be caused by ______________. A. dirt or grease on pole faces B. mechanical interference in the contacts C. chattering contacts on the control relay D. magnetic lock out of the contacts

Last Answer : Answer: C

Description : Which type of AC single-phase motor will also operate on direct current? A. Split-phase B. Series-wound C. Shaded-pole D. Repulsion-start

Last Answer : Answer: B