Why The Air Gap Between The Pole Pieces And The Armature Is Kept Very Small?

1 Answer

Answer :

The air gap between the pole pieces and the armature is kept very small to keep the field strength at its highest value.
This is due to the reason the flux lines can pass through iron very easily than the air gap.
The small air gap generates high voltage.
Larger the air gap me stronger must be the magnetizing force to produce the required voltage hence the air gap is kept very small.

Related questions

Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above

Last Answer : (e) All of the above

Description : The air gap in an induction motor should be checked periodically with a feeler gage to detect ____________. A. rotor contact with the laminations B. changes in armature magnetic strength C. excessive bearing wear D. electrical damage to the rotor

Last Answer : Answer: C

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : The introduction of interpoles in between the main pole improves the performance of d.c. machines, because (A) The interpole produces additional flux to augment the developed torque. (B) The flux waveform is ... armature is removed. (D) A counter e.m.f. is induced in the coil undergoing commutation.

Last Answer : Ans: D Counter e.m.f is produced, it neutralizes the reactive emf.

Description : Brush sparking during commutation may be caused by ________. A. eddy currents in the armature core B. laminations in the generator field pieces C. induced current opposite to coil inductance D. coil inductance discharge occurring at commutation

Last Answer : Answer: D

Description : In induction motors, the length of air gap in kept as small as mechanically possible is order to have (a) low power factor (b) high power factor (c) high over load capacity (d) any of the above

Last Answer : (b) high power factor

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : Which one of the following statements for a dc machine which is provided with inter pole winding (IW) as well as compensating winding (CW) is correct a) Both IW and CW are connected in ... parallel with Armature winding d) CW connected in series but IW is connected in parallel with Armature winding

Last Answer : Ans: Both IW and CW are connected in series with Armature winding

Description : In DC generators, armature reaction is produced actually by (A) Its field current. (B) Armature conductors. (C) Field pole winding. (D) Load current in armature.

Last Answer : Ans: D Because load current in armature gives rise to armature mmf which react with main field mmf.

Description : The relay operating speed depends upon (a) the spring tension (b) the rate of flux built up (c) armature core air gap (d) all of the above

Last Answer : (d) all of the above

Description : In the motors starting purpose why the armature rheostats at maximum position while the field rheostat is kept in minimum position?

Last Answer : A: In the time of starting a motor the field rheostat is kept in minimum state for the high starting torque. In the time of starting a motor the armature rheostats is used to control or reduce the high starting current. This high starting current can damage the motors starting systems.

Description : Why the air gap of an induction motor is made as small as possible?

Last Answer : The mmf and the magnetizing current are primarily decided by length of air gap. If air gap is small then mmf and magnetizing current will be low, which in turn increase the value of power factor. Hence by keeping small air gap, high power factor is achieved.

Description : Two 12 ft. sections of aluminum siding are placed end to end on the outside wall of house. How large a gap should be left between the pieces to prevent buckling if the temperature can change by 55˚C?  a. 0.21 m  b. 0.18 m  c. 0.31 in  d. 0.18 in

Last Answer : 0.18 in

Description : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is  (A) 96 V (B) 192 V (C) 384 V (D) 768 V

Last Answer : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is 384 V

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

Description : The number of parallel paths in armature winding of four pole wave winding connected dc machine having 22 coil sides is (1) 4 (2) 22 (3) 2 (4) 11 

Last Answer : Ans- Option (3) because wave winding always have 2 parallel paths

Description :  The number of parallel paths in the armature winding of a 4 -pole, wave connected d.c. machine having 28 coilside is : -  a) 28 b) 14 c) 4 d) 2

Last Answer : 2

Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature

Last Answer : Answer: B

Description : The purpose of a motor undervoltage protection device is to _____________. A. prevent high armature current when power is restored B. start the motor at a very low voltage C. trip the load off the motor in case of fire D. protect personnel from low voltage shocks

Last Answer : Answer: A

Description : Which of the following statement(s) is/are correct concerning cell junctions? a. The major occluding junction is the tight junction or zonula occludens b. Tight junctions are usually located near ... adjacent cells d. Gap junctions are a type of cell junction specialized for cell communication

Last Answer : Answer: a, c, d Cell junctions are classified as occluding, anchoring, and communicating. The major occluding junction is the tight junction or zonula occludens which connects ... gap junction which is specialized for communication. This junction mediates both electrical and chemical coupling

Description : The pole pieces of the magnet used in a pivoted coil galvanometer are

Last Answer : The pole pieces of the magnet used in a pivoted coil galvanometer are A. plane surfaces of a ... magnet D. cylindrical sufaces of a horse-shoe magnet

Description : What advantage is gained by using pole pieces with curved faces in the D’Arsonval meter movement?

Last Answer : Two-position and three-position.

Description : Which one of the following statements regarding septic tanks is wrong? A. A gap of 7.5 cm between the bottom of the covering slab and the top level of scum is provided B. The outlet invert level is kept ... . The minimum width of septic level is 90 cm D. The depth of tank is kept equal to its width

Last Answer : ANS: D

Description : Generally the gap between the contact breaker points is kept between a) 0 .1 to 0.3 mm b) 0.2 and 0.4 mm c) 0.3 and 0.5 mm d) 0 .4 and 0.6 mm

Last Answer : c) 0.3 and 0.5 mm

Description : Unnecessary and frequent applications of varnish to the generator windings to repair defective insulation will result in ____________. A. heavy coatings of varnish interfering with heat dissipation B. ... of the rectifier assembly D. a built-up of varnish without changing generator operation

Last Answer : Answer: A

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END-AFT END, Top .045 - .049, Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : Air gap readings should be taken on electrical generation machinery periodicly to _________. I. determine the need for cleaning II. check the condition of the bearings A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: B

Description : Air gap readings for electrical generating equipment should be taken periodicly. This is to _______. I. determine the condition of the bearings II. prevent damage to the rotor and stator A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: C

Description : Air gap readings should be taken on electrical generation equipment periodicly to ________. I. check machine effeciency II. determine the need for cleaning A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: D

Description : Air gap readings should be periodicly taken for electrical generation equipment. The best tool to use to take these measurements is a ___________. A. cloth (non-metalic) tape measure B. dial indicator C. inside micrometer D. tapered, long blade, feeler gage

Last Answer : Answer: D

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : Air gap readings should be taken periodicly on electrical generation equipment to __________. A. determine the amount of varnish that can be applied to correct insulation problems B. determine the ... field coil bolts and correct lateral adjustment of the field coils D. increase machine efficiency

Last Answer : Answer: B

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END -AFT END, Top .045 - .049 , Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : The air gap in an induction motor should be periodically checked with a feeler gage to prevent possible ___________. A. rotor contact with the stator B. axial misalignment of the rotor C. damage to the motor bearings D. electrical damage to the bearings

Last Answer : Answer: A

Description : The air gap provided in induction motors should be checked periodically with a feeler gage to detect an unequal air gap and _____________. A. decreased motor magnetizing current B. hysteresis loses C. increased power factor D. mechanical damage to the rotor

Last Answer : Answer: D

Description : The horizontal line which cuts across 'L1' shown in figure 'A' of the illustration indicates a/an ______________. EL-0091 A. iron core B. saturable core C. air gap D. capacitive coupling

Last Answer : Answer: B

Description : The rotor slots of a repulsion-type motor are generally skewed (placed nonparallel to the rotor axis) to _________. A. produce a constant starting torque B. permit a greater air gap with the starter C. permit a smaller air gap with the starter D. reduce eddy current losses

Last Answer : Answer: A

Description : What happens if the air gap flux density in an induction motor increases?

Last Answer : The increase in air gap flux increases iron loss and hence efficiency decreases.

Description : What happens if the air gap length is doubled?

Last Answer : If the air gap of an induction motor is doubled then the mmf and magnetizing current approximately doubles. Also increase in air gap length increases the overload capacity, offers better cooling, reduces noise and reduces unbalanced magnetic pull.

Description : What are the advantages and disadvantages of large air gap length in induction motor?

Last Answer : Advantage: A large air gap length results in higher overload capacity, better cooling, reduction in noise and reduction in unbalanced magnetic pull. Disadvantages: The disadvantage of large air gap length is that it results in high value of magnetizing current.

Description : In an induction machine, if the air gap increased a) Speed will be reduced b) Efficiency will be improved c) Power factor will be lowered d) Breakdown torque will be reduced

Last Answer : Ans: Power factor will be lowered

Description : What happens if bone of frog is kept in dilute hydrochloric acid? (a) Will become flexible (b) Will turn black (c) Will break into pieces(d) Will shrink

Last Answer : (a) Will become flexible

Description : A hollow circular pipe with non-reflective inner surface is cut into 5 pieces and arranged as shown in the figure below. If it is illuminated from below using a torch as shown in the figure, what would be the profile of the light falling on the sheet kept above?

Last Answer : A

Description : If the field circuits of an unloaded salient pole synchronous motor gets suddenly open circuited, then (A) The motor stops. (B) It continues to run at the same speed. (C) Its runs at the slower speed. (D) It runs at a very high speed.

Last Answer : Ans: B The motor continues to run at the same speed because synchronous motor speed does not depend upon load, Nα f.