Air gap readings should be periodicly taken for electrical generation equipment. The best tool to use to take these measurements is a ___________. A. cloth (non-metalic) tape measure B. dial indicator C. inside micrometer D. tapered, long blade, feeler gage

1 Answer

Answer :

Answer: D

Related questions

Description : Air gap readings should be taken on electrical generation equipment periodicly to ________. I. check machine effeciency II. determine the need for cleaning A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: D

Description : Air gap readings should be taken periodicly on electrical generation equipment to __________. A. determine the amount of varnish that can be applied to correct insulation problems B. determine the ... field coil bolts and correct lateral adjustment of the field coils D. increase machine efficiency

Last Answer : Answer: B

Description : Air gap readings should be taken on electrical generation machinery periodicly to _________. I. determine the need for cleaning II. check the condition of the bearings A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: B

Description : Air gap readings for electrical generating equipment should be taken periodicly. This is to _______. I. determine the condition of the bearings II. prevent damage to the rotor and stator A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: C

Description : The air gap in an induction motor should be periodically checked with a feeler gage to prevent possible ___________. A. rotor contact with the stator B. axial misalignment of the rotor C. damage to the motor bearings D. electrical damage to the bearings

Last Answer : Answer: A

Description : The air gap in an induction motor should be checked periodically with a feeler gage to detect ____________. A. rotor contact with the laminations B. changes in armature magnetic strength C. excessive bearing wear D. electrical damage to the rotor

Last Answer : Answer: C

Description : The air gap provided in induction motors should be checked periodically with a feeler gage to detect an unequal air gap and _____________. A. decreased motor magnetizing current B. hysteresis loses C. increased power factor D. mechanical damage to the rotor

Last Answer : Answer: D

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D

Description : When you check the specific gravity of the battery electrolyte with a hydrometer, it should be kept in mind that ____________. A. the battery is fully charged when the indicator floats low in ... taken immediately after water is added to the cell D. temperature has no effect on hydrometer readings

Last Answer : Answer: C

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : As a general rule, the first troubleshooting action to be taken in checking faulty electric control devices is to _____________. A. draw a one line diagram of the circuitry B. test all fuses and measure the line voltage C. take megger readings D. insulate the apparatus from ground

Last Answer : Answer: B

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END-AFT END, Top .045 - .049, Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END -AFT END, Top .045 - .049 , Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : Pick up the correct statement from the following: (A) The lines of sight while observing back sight and fore sight lie in the same horizontal plane (B) The staff readings are measurements made ... readings are taken, coincides with the level surface through the telescope axis (D) All the above

Last Answer : (D) All the above

Description : When working on electrical circuits containing large capacitors, in addition to deenergizing the circuit, which of the listed precautions should also be taken? A. Keep all radio equipment ... capacitor insulation resistance. C. Ground the capacitor terminals. D. Check capacitor circuit polarity.

Last Answer : Answer: C

Description : The cross-sectional area of shipboard electrical cable is expressed in _____________. A. millimeters B. gage numbers C. centimeters D. circular mils

Last Answer : Answer: D

Description : Most appropriate instrument for measurement of internal and external diameter of a tube is A. vernier callipers B. micrometer screw gauge C. meter rule D. measuring tape

Last Answer : vernier callipers

Description : Grease coatings on electrical contact surfaces increase contact resistance and should be removed with a/an _______________. A. small wire brush B. compressed air jet C. clean dry cloth D. 10% solution carbon solvent and water

Last Answer : Answer: C

Description : Which of the following statements best describes the material known as varnished cambric? A. Felted asbestos sealed with varnish. B. Cotton cloth coated with insulating varnish. C. Rubber ... Paper impregnated with mineral oil, specially wrapped with nonmetallic tape, and coated with varnish.

Last Answer : Answer: B

Description : A galvanometer is an instrument used to measure ___________. A. thickness of galvanized metal B. resistance of electrical wiring insulation C. very small amounts of current or voltage D. quantity of galvans in an electric circuit

Last Answer : Answer: C

Description : When you clean a slicer set the blade control indicator to?

Last Answer : Feel Free to Answer

Description : Which of the listed conditions could indicate the need for cleaning electrical insulation? A. Low ambient temperature B. Low operating temperature C. High dielectric strength D. Low megger readings

Last Answer : Answer: D

Description : Before using a volt-ohmmeter to measure resistance readings, you should _____________. A. replace all batteries B. test the insulation resistance of the leads C. make sure the test leads do not touch D. hold the leads together and 'zero' the meter

Last Answer : Answer: D

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : The proper way to apply plastic electrical tape to an electric cable splice is to _____________. A. apply tape to the braided cover, but avoid touching it B. wind the tape so that each turn overlaps ... tape in one non-overlapping layer only D. heat the tape with a soldering iron for good bonding

Last Answer : Answer: B

Description : You are calibrating a multimeter using internal batteries to supply power for resistance measurements. However, you are unable to adjust the pointer to 'zero' using the adjustment knob. Therefore, you should ... change scales to the R X 100 scale and adjust using the 'zero ohms' adjusting knob

Last Answer : Answer: A

Description : What is the least count of out-side micrometer?  

Last Answer : The least count of out-side micrometer is 0.01mm. 

Description : The soft silvery metalic element which ionizes easily when heated or exposed to light and is present in atomic clocks is – (1) Cerium (2) Cesium (3) Calcium (4) Californium

Last Answer : (2) Cesium Explanation: 1967, based on Einstein defining the speed of light as the most constant dimension in the universe, the International System of Units isolated two specific wave counts ... cesium has lowest ionization energy and hence it can show photoelectric effect to the maximum extent.

Description : The soft silvery metalic element which ionizes easily when heated or exposed to light and is present in atomic clocks is : (1) Cerium (2) Cesium (3) Calcium (4) Califonrium

Last Answer : Cesium

Description : Manometers measure the __________ pressure. (A) Vacuum as well as the atmospheric (B) Difference in (C) Absolute (D) Gage

Last Answer : (B) Difference in

Description : You plan to measure your tape recorder’s SNR. What test equipment will you need?

Last Answer : A VTVM and a signal generator.

Description : Sele(A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement. (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement

Description : Select the correct statement. (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter

Description : Which of the following represents the accepted method of cleaning dust and foreign particles from electrical equipment while limiting damage to electric components? A. Carefully wiping off the components ... the components. D. Using carbon tetrachloride as a cleaning solvent to clean the components.

Last Answer : Answer: C

Description : Can you replace the razor blade that is in the razor knife that is included with the Evolv 10 pc. Homeowner Tool Set ?

Last Answer : Yes the blade is easy to replace.

Description : ECE Board Exam March 1996 Crosstalk coupling is ___________. A. dBm (disturbing pair) minus dBm (disturbed pair) B. the difference between readings on a cable pair with a tone and a cable pair without ... a cable C. signals from one circuit that get into another circuit D. All of these are true

Last Answer : D. All of these are true

Description : In precision theodolite traverse if included angles are read twice and the mean reading accepted using both verniers having a least count of 30". Assuming the instrument to be in perfect adjustment, linear measurements correct to 6 mm per ... legs) (A) 50" n (B) 30" n (C) 60" n (D) None of these

Last Answer : (A) 50" n

Description : Explain in brief linear measurements using: {i) Chaining (ii) Digital Tape

Last Answer : i. Chaining:  a. Linear measurement with chain carried out by two chainmen-Leader and follower.  b. The follower keeps the chain handle at starting station point, holds firmly it and directs the ... is at right spot, press the button and tape measures, calculates and displays distance on screen.

Description : An ammeter reads slightly above 'zero' when its leads are disconnected, this is a result of ___________. A. mechanical misalignment of the meter pointer B. a poor ground for the meter case C. static electricity in the air D. resistors inside the meter storing charges

Last Answer : Answer: A

Description : A metallic tape is made of (a) Steel (b) Invar (c) Linen (d) Cloth & wires*

Last Answer : (d) Cloth & wires

Description : Your employer makes an attempt to update office sterilization procedures; what would you recommend as the BEST method to verify that sterilization has occurred:** A. Use spore test daily B. Use ... daily and spore test monthly E. Use colour change tape in each load and spore tests weekly

Last Answer : E. Use colour change tape in each load and spore tests weekly

Description : Dumpy level is most suitable when (A) The instrument is to be shifted frequently (B) Fly levelling is being done over long distance (C) Many readings are to be taken from a single setting of the instrument (D) All of the above

Last Answer : (C) Many readings are to be taken from a single setting of the instrument

Description : Dumpy level is most suitable when (a) The instrument is to be shifted frequently (b) Fly leveling is being done over long distance (c) Many readings are to be taken from a single setting of the instrument* (d) All of the above

Last Answer : (c) Many readings are to be taken from a single setting of the instrument*

Description : The 'dielectric constant' is a numerical value indicating the effectiveness of a dielectric material in comparison to that of a standard, which is _______________. A. paper or cloth B. glass or mica C. plastic or Teflon D. dry air or a vacuum

Last Answer : Answer: D

Description : Controller contacts should be routinely cleaned by ________. A. blowing with compressed air B. filing with a bastard file C. wiping with a clean dry cloth D. dressing with crocus cloth

Last Answer : Answer: C

Description : A tool that allows an advertiser to compare the costs of several vehicles within a specific medium relative to the number of persons reached by each vehicle is called a A)cost comparison indicator. B)media comparison selector. C)unit -price selector. D)cost/person index. E)vehicle/price indicator.

Last Answer : A)cost comparison indicator.

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C