Which of the listed procedures is the best way to tell if a motor has become overloaded? A. Measure the current flow and compare it with the motor full load current flow as shown on the nameplate. B. Feel the motor and judge by the temperature. C. Watch for telltale signs of smoke coming from the motor. D. Periodic opening of the O/L relay coil

1 Answer

Answer :

Answer: A

Related questions

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : A three-phase, induction-type motor experiences an open in one phase. Which of the listed automatic protective devices will prevent the machine from being damaged? A. Overspeed trip B. Thermal overload relay C. Three-pole safety switch D. Magnetic blowout coil

Last Answer : Answer: B

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : If you hear a loud buzzing noise coming from a magnetic motor controller, you should ____________. A. assume that the motor is operating at a full load B. assume that the controller is operating normally C. ... of the problem D. feel the outside of the casing with your hand to see if it is hot

Last Answer : Answer: C

Description : If the motor shown in the illustration will not start when 'Q' is depressed, which of the listed components should be checked FIRST? EL-0017 A. Fuses 'F-1' and 'F-2'. B. Operating coil 'C'. C. Contacts 'H-1', 'H-2', and 'H-3'. D. Contact 'H-4'.

Last Answer : Answer: A

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : Which component is responsible for energizing solenoid 'B1-B2' and releasing the brake for the winch motor shown in the illustration? EL-0102 A. Contactor '3M' B. A spring not shown in the schematic diagram C. Resistor 'B2-R1' D. Relay 'FR-B.O.'

Last Answer : Answer: A

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : The contacts operated by the D.C. relay coil shown in the illustration are located in the schematic diagram prints at coordinates ____________. EL-0100 A. '41Y' on this page B. '52M52M' and '52H35M' C. '57R' on this page D. '52N' on page '57R'

Last Answer : Answer: C

Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield

Last Answer : Answer: B

Description : Power necessary to operate the horn shown in the illustration _____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through a relay coil D. also lights lamps 'R' and 'T'

Last Answer : Answer: B

Description : As shown in the illustration, which of the operations listed will happen when the 'jog button' is pushed? EL-0010 A. Coil 'CR' closes the normally open 'CR' contacts. B. Coil 'M' opens contact 'M'. C. Coil 'M' closes contact 'M'. D. Contact 'M' remains open despite the jog button being pushed.

Last Answer : Answer: C

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : One item listed on the name plate of a cargo pump motor is 'degrees centigrade rise.' This number is based on _____________. A. normal temperature change from cold to hot B. an ambient temperature ... . minimum heat rise from no load to full load D. maximum degrees centigrade rise from absolute zero

Last Answer : Answer: B

Description : To stop the electric motor shown in the illustration, the stop button is depressed, causing ____________. EL-0012 A. coil 'MS' to become de-energized B. contacts 'CR1' and 'MR4' to open C. contacts 'MR1', 'MR2', and 'MR3' to open D. contacts 'MS1', 'MS2', and 'MS3' to open

Last Answer : Answer: C

Description : Which of the listed procedures should be carried out to prevent moisture damage to electrical apparatus during extended periods of idleness? A. Fill the motor housing with CO2 to inert the space. B. Strap ... C. Place heat lamps in the motor housings. D. Cover the equipment with a canvas tarpaulin.

Last Answer : Answer: C

Description : What are the telltale signs that a tree is infected by emerald-ash-borer?

Last Answer : From SaveYourAsh.org – “Evidence that may indicate the presence of emerald ash borers include dying branches at the top of a tree, vertical bark splitting, new branches sprouting from the base of the tree, D-shaped exit holes and increased woodpecker damage.”

Description : What are the telltale signs of insecurity?

Last Answer : Depends. Physically insecure or emotionally insecure? Either way, there can be a pretty long list. Having to look perfect is one of them. Another is never being able to state in front of people how you ... can be a sign that someone is insecure. Many things. That's just the tip of the iceberg.

Description : What are telltale bed bugs signs in a home?

Last Answer : Bed bugs can be located relatively easily. Look under your sheets for small dark spots, these are blood stains. Also check the mattress for droppings, shed skins off of growing bed bugs, and the ... themselves. Don't forget to look behind headboards, in couches, even the top corners of ceilings.

Description : The motor starts when the start button in the illustration is pushed, but stops when the button is released the trouble is _________. EL-0007 A. the incorrect thermal overload coil B. a faulty 'M' coil C. a dirty contact on the Disc.Sw. at 'L3' D. a faulty holding relay contact

Last Answer : Answer: D

Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : The devices located at coordinates '49W' in the illustration represents a/an _________. EL-0100 A. A.C. motor B. A.C. relay coil C. D.C. motor D. D.C. buzzer

Last Answer : Answer: B

Description : The device at coordinates '63/1' in the illustration represents a/an _____________. EL-0100 A. A.C. buzzer B. A.C. motor C. D.C. motor D. D.C. relay coil

Last Answer : Answer: D

Description : Low voltage releases as used in some shipboard motor starter and control equipment will have which of the following characteristics? A. They trip circuit contactors when the motor starts to overspeed. B. ... coil of the starter. D. They allow the motor to restart upon restoration of normal voltage.

Last Answer : Answer: D

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : Which of the instruments listed could be use to locate a grounded field coil in a synchronous motor? A. Ammeter B. Voltmeter C. Megohmmeter D. Frequency meter

Last Answer : Answer: C

Description : Which of the listed instruments can be best used to locate a grounded field coil in a synchronous motor? A. Frequency meter B. Megohmmeter C. Voltmeter D. Multimeter

Last Answer : Answer: B

Description : A circuit breaker and a fuse have a basic similarity in that they both _____________. A. can be reset to energize the circuit B. should open the circuit when overloaded C. will burn out when an over current flow develops D. all of the above

Last Answer : Answer: B

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : Which of the following statements describes what will occur if the motor shown in the illustration is required to carry 150% of full load? EL-0056 A. The primary counter emf will be increased. B. ... slip will decrease. D. The slip value, stator current curve, and torque curve will all coincide.

Last Answer : Answer: B

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : Which of the listed motors will operate at the highest RPM, assuming that each operates at the same frequency? A. A four-pole synchronous motor under normal load. B. A four-pole induction motor under ... A six-pole synchronous motor under normal load. D. A six-pole induction motor under full load.

Last Answer : Answer: A

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : A fuse will 'blow' if _____________. A. an electric motor is stopped suddenly by opening a switch B. the flow of current to the protection device is reversed C. the electrical current exceeds the rated value of the fuse D. unequal resistors are connected in parallel

Last Answer : Answer: C

Description : A loud buzzing noise in an AC controller is probably caused by _____________. A. poor contact with the overload relay B. an incorrectly sized heater C. a broken shading coil D. abnormal starting current

Last Answer : Answer: C

Description : If a magnetic controller relay fails to drop out when the coil voltage is removed from the relay, the probable cause may be _____________. A. excessive spring tension B. overvoltage C. excessive current D. welded contacts

Last Answer : Answer: D

Description : When the master switch for the winch shown in the illustration is in the 'off' position, and the line & safe switches are closed, which of the listed relays should be energized? EL-0102 A. 'DB' & '2T' B. 'DB' & '4M' C. 'FR-B.O.' & 'LV' D. '1M' & '1A'

Last Answer : Answer: C