How A Phase Converter Works?

1 Answer

Answer :

What a phase converter is a device that can take a single phase of electrical current and turn it into a multiple phase electrical current. The most common type of phase converter is single to triple phase power. When this occurs it takes the power of three different power conductors which peaks evenly and around one third before the other. There are three different types of phase converters. They are digital phase converter, rotary phase converter, and a static phase converter. Although all three types of phase converters produce about 1/3 voltage and add to the other two voltages found within the converter, they accomplish this in different ways. The rotary phase converter uses a separate motor which is three phase. It also uses a group of capacitors which in unison work as one large cap

Related questions

Description : how to convert Works to PDF over the free converter limit

Last Answer : Need Answer

Description : How to compute the load of your phase converter?

Last Answer : A lot of people don't understand the main function of this smallbut very useful device called a phase converter. This device wasmade for the purpose of changing single electrical power into ... own. Oftentimes people tend to step back when trying tocreate electrical equipment, but little do the

Description : How do I figure out what size rotary phase converter I need?

Last Answer : To figure out what size rotary phase converter you need to figure out what type of equipment you have, how difficult is to start, and the AMP requirements of it. ... phase converters and figure out which one you need. http://www.rotaryphaseconverter.info/selectingrightsizerotaryphaseconverter.htm

Description : What is the main use of rotary phase converter ?

Last Answer : Rotary phase converter will be converting single phase power into true balanced 3 phase power,so it is often called as single phase to three phase converter .Often the advantages of 3 phase motors, and other 3 ... for the extra cost of a 3 phase service but may still wish to use 3 phase equipment.

Description : What is the different between digital phase converter and ordinary phase converter?

Last Answer : Answer:Digital phase converter are a recent development in phase converter technology that utilizes proprietary software in a powerful microprocessor to control solid state power switching components. ... of the converter to maintain perfectly balanced three-phase power under all load conditions.

Description : What are the advantages of single phase bridge converter over single phase mid-point converter?

Last Answer : a. SCRs are subjected to a peak-inverse voltage of 2Vm in a fully controlled bridge rectifier. Hence for same voltage and currnt ratings of SCrs, power handled by mid-point configuration is about ... load power. As such, the transformer rating in mid-point converter is double the load rating.

Description : How to Build a Static 3 Phase Converter

Last Answer : How to Build a Static 3 Phase Converter Static 3 phase converters enable offices and residents to conserve energy efficiently. In fact, electricity is available in 3 power phases, which enables ... converter and the necessary appliances that are needed in building the main and the remote appliances.

Description : Draw single phase full wave mid-point converter for inductive load. Draw input and output waveforms for it. 

Last Answer : Circuit Diagram: Waveforms:

Description : Give the operation of single phase full wave bridge controlled converter with RL load with a neat diagram. Also draw its waveform.

Last Answer : Single phase fully control bridge converter with RL load: 1. During positive half cycle of input voltage, T1 and T2 are forward biased and during negative half cycle, T3 and T4 are forward biased. Therefore, T1-T2 ... cycle till the firing of next pair of SCRs as shown in the waveform.

Description : A separately excited d.c. motor fed from single phase full converter with firing angle 60° runs at 1000 r.p.m. If motor is connected to single phase semiconverter with the same firing angle of 60°, it would run at (a) 2000 rpm (b) 1850 rpm (c) 1500 rpm (d) 1000 rpm 

Last Answer : Ans =1500

Description : A freewheeling diode in a phase controlled converter  A) Deceases the possibility of discontinuous conduction in the load B) Increases the possibility of discontinuous conduction in the load C) Reduces the power factor and causes over voltages D) Causes over voltages

Last Answer : A freewheeling diode in a phase controlled converter Deceases the possibility of discontinuous conduction in the load 

Description : A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60o. The load current is assumed constant at 10 A due to high load inductance. The input ... 0.552 (C) IDF IPF = = 0.5; 0.478 (D) IDF IPF = = 0.5; 0.318 

Last Answer : A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60o. The load current is assumed constant at 10 A due to high ... (IDF) and the input power factor (IPF) of the converter will be IDF IPF = = 0.5; 0.478

Description : A single phase full-wave half-controlled bridge converter feeds an inductive load. The two SCRs in the converter are connected to a common DC bus. The converter has to have a freewheeling diode.  (A) ... to one of the SCRs is missed, it will subsequently cause a high load current in the other SCR.

Last Answer : A single phase full-wave half-controlled bridge converter feeds an inductive load. The two SCRs in the converter are connected to a common DC bus. The converter has to have a freewheeling diode. because the converter does not provide for free-wheeling for high values of triggering angles

Description : A three-phase, fully controlled thyristor bridge converter is used as line commutated inverter to feed 50 kW power 420 V dc to a three-phase, 415 V(line), 50 Hz ac mains. Consider dc link current to be constant. The rms current of the thyristor is  (A) 119.05 A (B) 79.37 A (C) 68.73 A (D) 39.68 A

Last Answer : A three-phase, fully controlled thyristor bridge converter is used as line commutated inverter to feed 50 kW power 420 V dc to a three-phase, 415 V(line), 50 Hz ac mains. Consider dc link current to be constant. The rms current of the thyristor is 68.73 A

Description : A single-phase fully controlled thyristor bridge ac-dc converter is operating at a firing angle of 25o and an overlap angle of 10o with constant dc output current of 20 A. The fundamental power factor (displacement factor) at input ac mains is  (A) 0.78 (B) 0.827 (C) 0.866 (D) 0.9

Last Answer : A single-phase fully controlled thyristor bridge ac-dc converter is operating at a firing angle of 25o and an overlap angle of 10o with constant dc output current of 20 A. The fundamental power factor (displacement factor) at input ac mains is 0.78

Description : A three phase fully controlled bridge converter is feeding a load drawing a constant and ripple free load current of 10 A at a firing angle of 30o. The approximate Total harmonic Distortion (%THD) and the rms value of fundamental component ... (B) 31% and 7.8 A (C) 66% and 6.8 A (D) 66% and 7.8 A

Last Answer : A three phase fully controlled bridge converter is feeding a load drawing a constant and ripple free load current of 10 A at a firing angle of 30o. The approximate Total harmonic Distortion (%THD) and the rms value of fundamental component of input current will respectively be 31% and 7.8 A

Description : A single phase fully controlled bridge converter supplies a load drawing constant and ripple free load current, if the triggering angle is 30o, the input power factor will be  (A) 0.65 (B) 0.78 (C) 0.85 (D) 0.866

Last Answer : A single phase fully controlled bridge converter supplies a load drawing constant and ripple free load current, if the triggering angle is 30o, the input power factor will be 0.78

Description : a single phase full wave midpoint thyristor converter uses a 230/200V transformer with centre tap on the secondary side. The P.I.V per thyristor is   (A) 100V (B)141.4V (C)200V (D)282.8V

Last Answer : d

Description : In a single-phase full converter, the number of SCRs conducting during overlap is   (a) 1 (b) 2 (c) 3 (d) 4 

Last Answer : 4

Description : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor :  (A) can be operated in first quadrant (B) ... in first & second quadrants (C) can be operated in first & fourth quadrants (D) cannot be operated

Last Answer : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor : can be operated in first & fourth quadrants

Description : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

Last Answer : Please show the solution for this question

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in (A) voltage notching (B) harmonic distortion (C) voltage sag (D) voltage swell

Last Answer : In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in voltage notching

Description : single phase full converter

Last Answer : single phase full converter

Description : As Kathy works on the prototype of a new action -orientated computer game module, she is engaging in which phase of the new product development process? A)idea generation B)commercialisation C)test marketing D)screening E)product development