A three phase overhead transmission line has its conductors horizontally spaced with spacing between adjacent conductors equal to 'd'. if now the conductors of the line are rearranged to form and the equilateral triangle of sides equal to 'd' then?

1 Answer

Answer :

A three-phase overhead transmission line has its conductors horizontally spaced with spacing between adjacent conductors equal to 'd'. if now the conductors of the line are rearranged to form and an equilateral triangle of sides equal to 'd' then average capacitance and inductance will increase.

Related questions

Description : A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows:A - B = 3m, B - C = 5m, C - A = 3.6mIf the line operates at 132 k V, the reactive voltampere generatd by the line per km is?

Last Answer : A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows:A - B = 3m, B - C = 5m, C - A = 3.6mIf the line operates at 132 k V, the reactive voltampere generated by the line per km is  51.70 kVAr.

Description : For equilateral spacing of conductors of an untrasposed 3-phase line, we have?

Last Answer : For equilateral spacing of conductors of an untrasposed 3-phase line, we have balanced receiving end voltage and communication interference.

Description : For a single phase overhead line having solid copper conductors of diameter 1 cm, spaced 60 cm between centers, the inductance in mH/km is?

Last Answer : For a single phase overhead line having solid copper conductors of diameter 1 cm, spaced 60 cm between centers, the inductance in mH/km is 0.05 + 0.2 ln (6010.5).

Description : The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

Last Answer : Vscos¢s-Vrcos¢r=IR

Description : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of ... the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

Last Answer : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, ... line. The voltage of the alternator neutral with respect to ground during the fault is 642.2 V

Description : A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is (A) 1204 MW (B) 1504 MW (C) 2085 MW (D) 2606 MW

Last Answer : A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is 2085 MW

Description :  A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is?

Last Answer :  A single-phase transmission line of impedance j 0.8 ohm supplies a resistive load of 500 A at 300 V. The sending end power factor is 0.6 lagging.

Description : ACSR (Aluminium Conductor Steel Reinforced) are used as (A) over head transmission lines. (B) super conductors. (C) fuse (D) underground cables.

Last Answer : (A) over head transmission lines.

Description : The skin effect in conductors is due to non uniform distribution of current in it and major portion of current is near the _______ of conductor.  (1) Surface (2) Center (3) Complete cross section area (4) Axis

Last Answer : The skin effect in conductors is due to non uniform distribution of current in it and major portion of current is near the Surface of conductor. 

Description : Corona loss can be reduced by the use of hollow conductors because?

Last Answer : Corona loss can be reduced by the use of hollow conductors because of better ventilation in the conductor.

Description : Whenever the conductors are dead-ended of there is a change in the direction of a transmission line, the insulator. used are of the?

Last Answer : Whenever the conductors are dead-ended of there is a change in the direction of a transmission line, the insulator. used are of the strain type.

Description : Bundled conductors are employed to improve the.  A) Appearance of the transmission line B) Mechanical stability of the line C) Current carrying capacity of the line D) Corona performance of the line

Last Answer : B

Description :  "Expanded ACSR" are conductors composed of ?

Last Answer :  "Expanded ACSR" are conductors composed of a fillter between the inner steel and the outer aluminium strands to increase the overall diameter of the conductor.

Description : When bundle conductors are used in place of single conductors, the effective inductance and capacitance will respectively

Last Answer : When bundle conductors are used in place of single conductors, the effective inductance and capacitance will respectively decrease and remain unaffected.

Description : A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will?

Last Answer : A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will progressively increase from the receiving end to the sending end.

Description : Choose two appropriate auxiliary components of a HVDC transmission system from the following P. D.C line inductor Q. A.C line inductor R. Reactive power sources S. Distance relays on D.C line T. Series capacitance on A.C. line  (A) P and Q (B) P and R (C) Q and S (D) S and T

Last Answer : Choose two appropriate auxiliary components of a HVDC transmission system from the following P. D.C line inductor Q. A.C line inductor R. Reactive power sources S. Distance relays on D.C line T. Series capacitance on A.C. line  (A) P and Q (B) P and R (C) Q and S (D) S and T

Description : The transmission line distance protection relay having the property of being inherently directional is (A) impedance relay (B) MHO relay (C) OHM relay (D) reactance relay

Last Answer : The transmission line distance protection relay having the property of being inherently directional is MHO relay

Description : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately (A) P (B) 2P (C) P / 2 (D) P / 4

Last Answer : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately P / 4

Description : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 ... load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

Last Answer : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/ ... MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be 36 

Description : An HVDC link consist of rectifier, inverter transmission line and other equipments. Which one of the following is true for this link ?  (A) The transmission line produces/ supplies ... ) Both the converters (rectifier and inverter) consume reactive power from the respective connected AC systems

Last Answer : An HVDC link consist of rectifier, inverter transmission line and other equipments. Which one of the following is true for this link ?  (A) The transmission line produces/ supplies ... ) Both the converters (rectifier and inverter) consume reactive power from the respective connected AC systems

Description : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be (A) 1835 MW (B) 2280 MW (C) 2725 MW (D) 3257 MW

Last Answer : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be 2280 MW

Description : For enhancing the power transmission in along EHV transmission line, the most preferred method is to connect a  (A) Series inductive compensator in the line (B) Shunt inductive compensator at the ... (C) Series capacitive compensator in the line (D) Shunt capacitive compensator at the sending end

Last Answer : For enhancing the power transmission in along EHV transmission line, the most preferred method is to connect a Series capacitive compensator in the line

Description : For a fixed value of complex power flow in a transmission line having a sending and voltage V, the real power loss will be proportional to  A) V B) v2 C) 1/V2 D)1/V

Last Answer : For a fixed value of complex power flow in a transmission line having a sending and voltage V, the real power loss will be proportional to 1/V2

Description : Which of the two generalized constants of a transmission line are equal?  (a) B & C (B) A & B (c) A & D (D) B & D

Last Answer : Which of the two generalized constants of a transmission line are equal?  (a) B & C (B) A & B (c) A & D (D) B & D

Description : Series capacitive compensation in EHV transmission line is used to

Last Answer : To maintain voltage stability 

Description : The transmission line feeding power on either side of the main transmission line is called?

Last Answer : The transmission line feeding power on either side of the main transmission line is called Secondary transmission.

Description : For a transmission line with negligible losses, the lagging reactive power (VAR) delivered at The receiving end, for a given receiving end voltage, is directly proportional to the?

Last Answer : For a transmission line with negligible losses, the lagging reactive power (VAR) delivered at The receiving end, for a given receiving end voltage, is directly proportional to the line voltage drop.

Description : The time taken for a surge to travel a 600 km long overhead transmission line is?

Last Answer : The time taken for a surge to travel a 600 km long overhead transmission line is 0.002s.

Description : A lossless radial transmission line with surge impedance loading?

Last Answer : A lossless radial transmission line with surge impedance loading takes negative VAr at sending end and zero VAr at receiving end.

Description : The line conductor of a transmission line has an overall diameter of 19.53 mm, weight 0.844 kg/m and an ultimate breaking strength of 7950 kg. If the factor of safety is to be 2, when conductor ... .5 kg/m. What is the vertical sag, corresponding to this loading for a 300 m span level supports?

Last Answer : The line conductor of a transmission line has an overall diameter of 19.53 mm, weight 0.844 kg/m and an ultimate breaking strength of 7950 kg. If the factor of safety is to be 2, when conductor ... 5 kg/m. 5.22 m is the vertical sag, corresponding to this loading for a 300 m span level supports.

Description : An overhead transmission line has a span of 240m between level supports. What is the maximum sag if the conductor weight 727 kg/km and has a breaking strength of 6880 kg? Allow the factor of safety of 2. Neglecting wind and ice loading.

Last Answer : An overhead transmission line has a span of 240m between level supports. 1.52 m is the maximum sag if the conductor weight 727 kg/km and has a breaking strength of 6880 kg? Allow the factor of safety of 2. Neglecting wind and ice loading.

Description : A transmission line conductor at a river crossing is supported from two towers at height. of 30 m and 90m, above water level. The horizontal distance between the towers is 270m, if the tension in ... . What is the clearance between the conductor and the water at a point midway between the towers?

Last Answer : A transmission line conductor at a river crossing is supported from two towers at height. of 30 m and 90m, above water level. The horizontal distance between the towers is 270m, if the tension ...  54.94 m is the clearance between the conductor and the water at a point midway between the towers.

Description : If in a short transmission line, resistance and inductance are found to be equal and regulation appear. to be zero, then the load will?

Last Answer : If in a short transmission line, resistance and inductance are found to be equal and regulation appear. to be zero, then the load will be 0.707 lagging.

Description : For an existing ac transmission line, the string efficiency is 80%, if dc voltage is supplied for the same setup, the string efficiency will be?

Last Answer : 100%

Description : A 100 km long transmission line is loaded at 110 kV.if the loss of line is 5 MW and the load is 150 MVA, the resistance of the line is?

Last Answer : P = I^2  *  R 5*10^6  = [(150*10^6) / (110*10^3)  *  R R = 2.7 ohm/phase

Description : A 100 km transmission line is designed for a nominal voltage of 132 kV and consists of one conductor per phase. The line reactance is 0.726 ohm/km. The static transmission capacity of the line, in MW, would be   (a) 240 (b) 132 (c) 416 (d) 720

Last Answer : A 100 km transmission line is designed for a nominal voltage of 132 kV and consists of one conductor per phase. The line reactance is 0.726 ohm/km. The static transmission capacity of the line, in MW, would be 240 

Description : In a DC transmission line?

Last Answer : In a DC transmission line there are no effects due to inductive and capacitive reactances.

Description : If the operating frequency is 450 MHz what length of a pair of conductors is considered to be a transmission line? A. 2.19 ft B. 2.19 m C. 0.219 ft D. 0.219 m

Last Answer : C. 0.219 ft

Description : A pair of current-carrying conductors is not considered a transmission line unless it is at least ___ λ long at the signal frequency. A. 0.1 B. 0.3 C. 0.2 D. 0.4

Last Answer : A. 0.1

Description : A transmission line consisting of two conductors that have equal resistance per unit length. A. Unbalanced line B. Open-wire line C. Balanced line D. Coaxial line

Last Answer : C. Balanced line

Description : The two conductors of a transmission line carry equal current I in opposite directions. The force on each conductor is (a) proportional to 7 (b) proportional to X (c) proportional to distance between the conductors (d) inversely proportional to I

Last Answer : (b) proportional to X

Description : Galloping in transmission line conductors arises generally due to - (A) asymmetrical layer of ice formation (B) vortex phenomenon in light winds (C) heavy weight of line conductors (D) adoption of horizontal conductor

Last Answer : D

Description : The conductor of a 10 km long, single phase, two wire line are separated by a distance of 1.5 m. The diameter of each conductor is 1 cm, If the conductors are of copper, the inductance of the circuit is

Last Answer : The conductor of a 10 km long, single phase, two wire line are separated by a distance of 1.5 m. The diameter of each conductor is 1 cm, If the conductors are of copper, the inductance of the circuit is 23.8 mH.

Description : Mareks Disease transmission occurs B A. Vertically B. horizontally C. by both above mentioned means D. None of these

Last Answer : horizontally

Description : The spacing between phase conductors of a 220 kV line is approximately equal to (a) 2 m (b) 3.5 m (c) 6 m (d) 8.5 m

Last Answer : (c) 6 m

Description : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is  (A) 1200 A (B) 3600 A (C) 35 kA (D) 104.8 kA

Last Answer : A three-phase, 33 kV oil circuit breaker is rated 1200 A, 2000 MVA, 3 s. The symmetrical breaking current is 35 kA 

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : High Voltage DC (HVDC) transmission is mainly used for  (A) bulk power transmission over very long distances (C) inter-connecting two systems with same nominal frequency (C) eliminating reactive power requirement in the operation (D) minimizing harmonics at the converter stations

Last Answer : High Voltage DC (HVDC) transmission is mainly used for bulk power transmission over very long distances 

Description : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the infinite bus voltage is 1 pu. The ... fault at the generator terminal is  (A) 53.5 (B) 60.2 (C) 70.8 (D) 79.6

Last Answer : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the ... clearing angle, in degrees, for a three-phase dead short circuit fault at the generator terminal is 79.6

Description : The power flow problem mathematical model for a linear transmission network (A) is non-linear (B) is linear (C) considers time variation of generation (D) does not consider tap-changing transformers