For a long uncompensated line the limit to the line loading ill governed by?

1 Answer

Answer :

For a long uncompensated line the limit to the line loading ill governed by stability limit.

Related questions

Description : For certain geometry and operating voltage of the uncompensated transmission line, the ratio of power transfer capability to the surge impedance loading with an increase in length

Last Answer : For certain geometry and operating voltage of the uncompensated transmission line, the ratio of power transfer capability to the surge impedance loading with an increase in length decreases.

Description : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be (A) 1835 MW (B) 2280 MW (C) 2725 MW (D) 3257 MW

Last Answer : A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be 2280 MW

Description : A lossless radial transmission line with surge impedance loading?

Last Answer : A lossless radial transmission line with surge impedance loading takes negative VAr at sending end and zero VAr at receiving end.

Description : Pick up the correct statement from the following: (A) An artificial barrier which makes the enclosed area safe for anchorage of ships, is known as break water (B) The break water whose inside is used ... wall is governed by the length of the largest vessel likely to be berthed (D) All the above

Last Answer : (D) All the above

Description : The loading dose of a drug is governed by its: A. Renal clearance B. Plasma half life C. Volume of distribution D. Elimination rate constant

Last Answer : C. Volume of distribution

Description : The loading dose of a drug is governed by its: A. Renal clearance B. Plasma half life C. Volume of distribution D. Elimination rate constant

Last Answer : C. Volume of distribution

Description : Which of the following features are present in blood chemistry in uncompensated metabolic alkalosis except? (A) Increased pH (B) Increased bicarbonate (C) Normal chloride (D) Normal pCO2

Last Answer : Answer : D

Description : All the following features are found in blood chemistry in uncompensated lactic acidosis except (A) pH is decreased (B) Bicarbonate is decreased (C) pCO2 is normal (D) Anion gap is normal

Last Answer : Answer : D

Description : A PD controller is used to compensate a system. Compared to the uncompensated system, the compensated system has: (1) A higher type number. (2) Reduced damping. (3) Higher noise amplification. (4) Larger transient overshoot. 

Last Answer : A PD controller is used to compensate a system. Compared to the uncompensated system, the compensated system has: Higher noise amplification.

Description : The relationship between the alternating stress and mean stress is given by the following equation: σ a =σ e [1-(σ m /σ u )x], where σ e is the fatigue limit for completely reversed loading. The value of x for Gerber line is equal to _________ a) 1 b) 2 c) 0.5 d) -1

Last Answer : b) 2

Description : The steady state stability limit as compared to the transient state stability limit is always

Last Answer : The steady state stability limit as compared to the transient state stability limit is always Greater

Description : When a material is subjected to fatigue loading, the ratio of the endurance limit to the ultimate tensile strength is (a) 0.20 (b) 0.35 (c) 0.50 (d) 0.65

Last Answer : (c) 0.50

Description : Factor of safety for fatigue loading is the ratio of (a) elastic limit to the working stress (b) Young's modulus to the ultimate tensile strength (c) endurance limit to the working stress (d) elastic limit to the yield point

Last Answer : (c) endurance limit to the working stress

Description : Under complex loading, if elastic limit reaches in tension, then failure occurs due to (a) Firstly Maximum principal strain theory (b) Secondly Maximum principal theory of strain energy (c) Thirdly Maximum Principal stress theory (d) None

Last Answer : (c) Thirdly Maximum Principal stress theory

Description : Under complex loading, if elastic limit reaches in tension, then failure occurs due to (a) Firstly Maximum principal strain theory (b) Secondly Maximum principal theory of strain energy (c) Thirdly Maximum shear stress theory (d) None

Last Answer : (d) None

Description : The concept of an electrically short, medium and long line is primarily based on the  A) Nominal voltage of the line B) Physical length of the line C) Wave length of the line D) Power transmitted over the line

Last Answer : The concept of an electrically short, medium and long line is primarily based on the  Physical length of the line 

Description : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

Last Answer : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as long line

Description : A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will?

Last Answer : A long overhead transmission line is terminated by its characteristic impedance. Under this operating condition, the ratio of the voltage to the current at different points along the line will progressively increase from the receiving end to the sending end.

Description : The time taken for a surge to travel a 600 km long overhead transmission line is?

Last Answer : The time taken for a surge to travel a 600 km long overhead transmission line is 0.002s.

Description : A 100 km long transmission line is loaded at 110 kV.if the loss of line is 5 MW and the load is 150 MVA, the resistance of the line is?

Last Answer : P = I^2  *  R 5*10^6  = [(150*10^6) / (110*10^3)  *  R R = 2.7 ohm/phase

Description : The conductor of a 10 km long, single phase, two wire line are separated by a distance of 1.5 m. The diameter of each conductor is 1 cm, If the conductors are of copper, the inductance of the circuit is

Last Answer : The conductor of a 10 km long, single phase, two wire line are separated by a distance of 1.5 m. The diameter of each conductor is 1 cm, If the conductors are of copper, the inductance of the circuit is 23.8 mH.

Description : In the long run price is governed by …………. (a) Cost of Production ; (b) Demand supply forces ; (c) Marginal utility ; (d) None

Last Answer : (a) Cost of Production ;

Description : The zero sequence current of a generator for line to ground fault is j 2.4 p.u. The current through the neutral during the fault is (a) j 0.8 p.u (b) j 2.4 p.u. (c) j 0.24 p.u. (d) j 7.2 p.u. 

Last Answer : j7.2

Description : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of ... the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

Last Answer : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, ... line. The voltage of the alternator neutral with respect to ground during the fault is 642.2 V

Description : Choose two appropriate auxiliary components of a HVDC transmission system from the following P. D.C line inductor Q. A.C line inductor R. Reactive power sources S. Distance relays on D.C line T. Series capacitance on A.C. line  (A) P and Q (B) P and R (C) Q and S (D) S and T

Last Answer : Choose two appropriate auxiliary components of a HVDC transmission system from the following P. D.C line inductor Q. A.C line inductor R. Reactive power sources S. Distance relays on D.C line T. Series capacitance on A.C. line  (A) P and Q (B) P and R (C) Q and S (D) S and T

Description : A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is (A) 1204 MW (B) 1504 MW (C) 2085 MW (D) 2606 MW

Last Answer : A 800 kV transmission line is having per phase line inductance of 1.1 mH/km and per phase line capacitance of 11.68 nF/km. Ignoring the length of the line, its ideal power transfer capability in MW is 2085 MW

Description : The transmission line distance protection relay having the property of being inherently directional is (A) impedance relay (B) MHO relay (C) OHM relay (D) reactance relay

Last Answer : The transmission line distance protection relay having the property of being inherently directional is MHO relay

Description : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately (A) P (B) 2P (C) P / 2 (D) P / 4

Last Answer : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately P / 4

Description : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 ... load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

Last Answer : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/ ... MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be 36 

Description : An HVDC link consist of rectifier, inverter transmission line and other equipments. Which one of the following is true for this link ?  (A) The transmission line produces/ supplies ... ) Both the converters (rectifier and inverter) consume reactive power from the respective connected AC systems

Last Answer : An HVDC link consist of rectifier, inverter transmission line and other equipments. Which one of the following is true for this link ?  (A) The transmission line produces/ supplies ... ) Both the converters (rectifier and inverter) consume reactive power from the respective connected AC systems

Description : For enhancing the power transmission in along EHV transmission line, the most preferred method is to connect a  (A) Series inductive compensator in the line (B) Shunt inductive compensator at the ... (C) Series capacitive compensator in the line (D) Shunt capacitive compensator at the sending end

Last Answer : For enhancing the power transmission in along EHV transmission line, the most preferred method is to connect a Series capacitive compensator in the line

Description : For a fixed value of complex power flow in a transmission line having a sending and voltage V, the real power loss will be proportional to  A) V B) v2 C) 1/V2 D)1/V

Last Answer : For a fixed value of complex power flow in a transmission line having a sending and voltage V, the real power loss will be proportional to 1/V2

Description : Which of the two generalized constants of a transmission line are equal?  (a) B & C (B) A & B (c) A & D (D) B & D

Last Answer : Which of the two generalized constants of a transmission line are equal?  (a) B & C (B) A & B (c) A & D (D) B & D

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Last Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then  (A) zero sequence currents are present on both sides of the transformer  (B) ... side  (D) zero sequence currents are present on the primary side but not on the secondary side

Last Answer : If an unsymmetrical line to ground fault occurs at the secondary terminals of a delta/star, ungrounded transformer, then zero sequence currents are absent on both sides of the transformer 

Description : Series capacitive compensation in EHV transmission line is used to

Last Answer : To maintain voltage stability 

Description : The sending end and receiving end voltages of a three-phase transmission line are 10 kV/ph and 9.5 kV/ph, respectively. If the resistance drop is 150 V/ph and receiving end power factor is 0.8, the sending end power factor is (A) 0.745 lagging (B) 0.775 lagging (C) 0.8 lagging (D) 0.85 lagging

Last Answer : Vscos¢s-Vrcos¢r=IR

Description : The transmission line feeding power on either side of the main transmission line is called?

Last Answer : The transmission line feeding power on either side of the main transmission line is called Secondary transmission.

Description : For a transmission line with negligible losses, the lagging reactive power (VAR) delivered at The receiving end, for a given receiving end voltage, is directly proportional to the?

Last Answer : For a transmission line with negligible losses, the lagging reactive power (VAR) delivered at The receiving end, for a given receiving end voltage, is directly proportional to the line voltage drop.

Description : The function of the earth wire in an extra high voltage line is to?

Last Answer : The function of the earth wire in an extra high voltage line is to provide a shield to the phase conductors from direct lightning stroke.

Description : A voltage of 1000 kV is applied to an overhead line with its receiving end open. If the surge impedance of the line is 500 ohm, then the total surge power in the line ill

Last Answer : A voltage of 1000 kV is applied to an overhead line with its receiving end open. If the surge impedance of the line is 500 ohm, then the total surge power in the line ill 2000 MW .

Description : A loss less line terminated with its surge impedance has

Last Answer : A loss less line terminated with its surge impedance has flat voltage profile.

Description : With 100 % series compensation of line.

Last Answer : the circuit is series resonant at power frequency and high transient current.

Description : A 60 Hz, 320 km lossless line has Bending end voltage 1.0 p.u, The receiving end voltage on no load is?

Last Answer : A 60 Hz, 320 km lossless line has Bending end voltage 1.0 p.u, The receiving end voltage on no load is 1.088 p.u.

Description : If a line is 100 % series compensated it may result into series resonance at power frequency of?

Last Answer : If a line is 100 % series compensated it may result into series resonance at power frequency of 50 Hz.

Description : The X:R ratio of 220 kV line as compared to 400 kV line is?

Last Answer : The X:R ratio of 220 kV line as compared to 400 kV line is smaller.

Description : A two conductor 1 - pi line operates at 50 Hz.The diameter of each conductor is 20 mm and the spacing between the conductors is 3m, The height of conductor above the ground is 6 m. The capacitance of the line to neutral will be?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 20 mm and the spacing between the conductors is 3m, The height of conductor above the ground is 6 m. The capacitance of the line to neutral will be 9.7 pF/m.

Description : A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows:A - B = 3m, B - C = 5m, C - A = 3.6mIf the line operates at 132 k V, the reactive voltampere generatd by the line per km is?

Last Answer : A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows:A - B = 3m, B - C = 5m, C - A = 3.6mIf the line operates at 132 k V, the reactive voltampere generated by the line per km is  51.70 kVAr.

Description : A two conductor 1 - pi line operates at 50 Hz.The diameter of each conductor is 4 cm and are spaced 6 m apart. What is the capacitive susceptance to neutral per km?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 4 cm and are spaced 6 m apart. 3.06 x 10-9 s/km is the capacitive susceptance to neutral per km.

Description : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 2 cm and are spaced 3m apart. What is the line to line capacitance ?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 2 cm and are spaced 3m apart.  4.87 x 10-9 F/km is the line to line capacitance.