1 Answer

Answer :

A moving coil instrument is used as an ohmmeter. The indicating scale of the meter will be Hyperbolic.

Related questions

Last Answer : In a dynamo-meter type of moving coil instrument a swamping resistance is provided inorder to: Provide equal time constant for moving coil and fixed coil, when used for ac measurement

Last Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Last Answer : The damping torque must operate only when the moving system of the indicating instrument is: Actually moving

Description : Prior to using an analog type ohmmeter, the leads are purposely shorted together. Which of the following actions should be taken if, when adjusting to 'zero' ohms, the indicating needle can not be ... be added to each final reading. D. The test reading should be subtracted from each final reading.

Last Answer : Answer: B

Last Answer :  In a moving coil instrument, the deflecting torque is proportional to Current.

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Last Answer : For the indicating instrument the preferred damping condition is  a damping coefficient of 0.8 to 1.

Last Answer : The pointer of an indicating instrument should be very light.

Description : The basic meter movement responds to the flow of current through its coil. Therefore, this meter movement may be used as a/an _____________. A. voltmeter by placing a resistance in parallel with the ... in parallel with the coil D. ammeter by placing a low resistance in parallel with the coil

Last Answer : Answer: D

Description : What is the reason why the scale of a permanent-magnet moving coil instrument is uniform?

Last Answer : because it is spring controlled

Description : What is the typical full-scale deflection current of a moving coil instrument?

Last Answer : 50mA

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is

Last Answer : A moving coil instrument of resistance 5 Ohm requires a potential difference of 75 mV to give a full scale deflection. The value of shunt resistance needed to give a full scale deflection at 30 A is 2.5 milliOhm

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Description : In order to check the performance of a transistor removed from its circuit, the instrument to be used should be a/an ____________. A. voltmeter or transistor tester B. impedance meter C. ohmmeter or transistor tester D. sensitive potentiometer

Last Answer : Answer: C

Description : A tunable RF instrument, which, by means of a sharp dip of an indicating meter, indicates resonance with an external circuit under test

Last Answer : dip meter

Description : A multipurpose instrument for measuring current, potential difference and resistance is a) Ohmmeter b) Astatic galvanometer c) Rheostat d) AVO Meter

Last Answer : d) AVO Meter

Description : Indicating instrument is assumed to be most accurate at what part of the scale?

Last Answer : at half or full

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointers to mid-scale B. change the meter's batteries C. center the meter's pointer at infinity D. short the test leads and calibrate the meter

Last Answer : Answer: D

Description : Before measuring an unknown resistance with an ohmmeter, you should _____________. A. adjust the meter's pointer to mid-scale B. short the test leads and calibrate the meter reading to 'zero' C. change the meter's batteries D. center the meter's pointer at infinity

Last Answer : Answer: B

Description : A capacitor can be tested using a megohmmeter or an ohmmeter. If the meter is connected to a shorted capacitor, the meter pointer should _____________. A. immediately swing to the maximum resistance ... deflect to and remain at zero D. immediately swing to a high reading and then gradually decrease

Last Answer : Answer: C

Description : A good choice of shunt resistance will place the indicating pointer near what part of the meter scale with a normal load?

Last Answer : Midscale.

Description : As the deflection of the moving system increases, the controlling torque in an indicating instrument.

Last Answer : increases

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Last Answer : The multiplier and the meter coil in a voltmeter are in series.

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Last Answer : In moving coil meters, damping is provided by eddy current disk.

Last Answer : In Weston synchronoscope the moving coil is connected across bus-bars.

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Description : Identify the instrument that does not exist (A) Dynamo-meter type ammeter (B) Dynamo-meter type wattmeter (C) Moving-iron voltmeter (D) Moving-iron wattmeter

Last Answer : Identify the instrument that does not exist (A) Dynamo-meter type ammeter (B) Dynamo-meter type wattmeter (C) Moving-iron voltmeter (D) Moving-iron wattmeter

Description : PMMC instrument gives uniform scale because:

Last Answer : PMMC instrument gives uniform scale because: It uses spring control and The deflection torque is proportional to the instrument current.

Last Answer : The gravity controlled instrument has crowded scale because current is proportional to sine of deflection angle.

Last Answer : If an instrument has cramped scale for larger values, then it follows logarithmic law.

Description : The ratio of maximum displacement deviation to full scale deviation of the instrument is called?

Last Answer : The ratio of maximum displacement deviation to full scale deviation of the instrument is called linearity.

Last Answer : The scale of a rectifier instrument is linear.

Description : A testing device called a 'growler' is being used to locate a shorted coil in the stator of an AC electrical machine. When the 'feeler' is moved over a slot containing the shorted coil _____________. ... . the meter needle will be deflected to zero D. the meter needle will be deflected to full-scale

Last Answer : Answer: A

Description : (True or False) The larger the current required to produce full-scale deflection of the meter coil, the better the sensitivity of the meter.

Last Answer : False.

Description : A galvanometer with 20 ohms coil resistence has a full-scale deflection of 10 mA. A 0.02 ohm is placed across the meter to increase its rating capacity. What is the new full scale current for the meter?

Last Answer : False.

Description : Eddy current damping cannot be used for moving iron instrument because

Last Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Last Answer : A moving iron instrument can be used for both D.C. and A.C.

Last Answer : In a moving iron meter, the deflecting torque is proportional to Square of the current through the coil.

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Description : The force required to move the pointer in an indicating instruments is

Last Answer : The force required to move the pointer in an indicating instruments is deflecting force

Last Answer : A Ohmmeter is basically: A ammeter

Description : When a capacitor was connected to the terminal of ohmmeter, the pointer indicated a low resistance initially and then slowly came to infinity position. This shows that capacitor is ?

Last Answer : When a capacitor was connected to the terminal of ohmmeter, the pointer indicated a low resistance initially and then slowly came to infinity position. This shows that capacitor is all right.

Last Answer : An ohmmeter is a moving coil instrument.

Description : Explain the construction and working of moving coil instrument.

Last Answer : Construction: The moving part is a coil wound on a light aluminium frame, mounted on a shaft made of stainless steel which is pivoted at either ends on jewel bearing made of sapphire. The coil is placed between ... . Where B is magnetic flux, N is number of turns and L is length of coil.