DC MOTOR MCQ

3 Answers

Answer :

1. No-load speed of which of the following motor will be highest ?
(a) Shunt motor
(b) Series motor
(c) Cumulative compound motor
(d) Differentiate compound motor
Ans: b
2. The direction of rotation of a D.C. series motor can be changed by
(a) interchanging supply terminals
(b) interchanging field terminals
(c) either of (a) and (b) above
(d) None of the above
Ans: b
3. Which of the following application requires high starting torque ?
(a) Lathe machine
(b) Centrifugal pump
(c) Locomotive
(d) Air blower
Ans: c
4. If a D.C. motor is to be selected for conveyors, which rriotor would be preferred ?
(a) Series motor
(b) Shunt motor
(c) Differentially compound motor
(d) Cumulative compound motor
Ans: a
5. Which D.C. motor will be preferred for machine tools ?
(a) Series motor
(b) Shunt motor
(c) Cumulative compound motor
(d) Differential compound motor
Ans: b
6. Differentially compound D.C. motors can find applications requiring
(a) high starting torque
(b) low starting torque
(c) variable speed
(d) frequent on-off cycles
Ans: b
7. Which D.C. motor is preferred for elevators ?
(a) Shunt motor
(b) Series motor
(c) Differential compound motor
(d) Cumulative compound motor
Ans: d
8. According to Fleming's left-hand rule, when the forefinger points in the direction of the
field or flux, the middle finger will point in the direction of
(a) current in the conductor aovtaat of conductor
(c) resultant force on conductor
(d) none of the above
Ans: a
9. If the field of a D.C. shunt motor gets opened while motor is running
(a) the speed of motor will be reduced %
(b) the armature current will reduce
(c) the motor will attain dangerously high speed 1
(d) the motor will continue to nuvat constant speed
Ans: c
10. Starters are used with D.C. motors because
(a) these motors have high starting torque
(b) these motors are not self-starting
(c) back e.m.f. of these motors is zero initially
(d) to restrict armature current as there is no back e.m.f. while starting
Ans: d
11. In D.C. shunt motors as load is reduced
(a) the speed will increase abruptly
(b) the speed will increase in proportion to reduction in load
(c) the speed will remain almost/constant
(d) the speed will reduce
Ans: c
12. A D.C. series motor is that which
(a) has its field winding consisting of thick wire and less turns
(b) has a poor torque
(c) can be started easily without load
(d) has almost constant speed
Ans: a
13. For starting a D.C. motor a starter is required because
(a) it limits the speed of the motor
(b) it limits the starting current to a safe value
(c) it starts the motor
(d) none of the above
Ans: b
14. The type of D.C. motor used for shears and punches is
(a) shunt motor
(b) series motor
(c) differential compoutid D.C. motor
(d) cumulative compound D.C. motor
Ans: d
15. If a D.C. motor is connected across the A.C. supply it will
(a) run at normal speed
(b) not run
(c) run at lower speed
(d) burn due to heat produced in the field winding by .eddy currents
Ans: d
16. To get the speed of D.C, motor below the normal without wastage of electrical energy
is used.
(a) Ward Leonard control
(b) rheostatic control
(c) any of the above method
(d) none of the above method
Ans: a
17. When two D.C. series motors are connected in parallel, the resultant speed is
(a) more than the normal speed
(b) loss than the normal speed
(c) normal speed
(d) zero
Ans: c
18. The speed of a D.C. shunt motor more than its full-load speed can be obtained by
(a) decreasing the field current
(b) increasing the field current
(c) decreasing the armature current
(d) increasing the armature current
Ans: a
19. In a D.C. shunt motor, speed is
(a) independent of armature current
(b) directly proportional to the armature current
(c) proportional to the square of the current
(d) inversely proportional to the armature current
Ans: a
20. A direct on line starter is used: for starting motors
(a) iip to 5 H.P.
(b) up to 10 H.P.
(c) up to 15 H.P.
(d) up to 20 H.P.
Ans: a
21. What will happen if the back e.m.f. of a D.C. motor vanishes suddenly?
(a) The motor will stop
(b) The motor will continue to run
(c) The armature may burn
(d) The motor will run noisy
Ans: c
22. In case of D.C. shunt motors the speed is dependent on back e.m.f. only because
(a) back e.m.f. is equal to armature drop
(b) armature drop is negligible
(c) flux is proportional to armature current
(d) flux is practically constant in D:C. shunt motors
Ans: d
23. In a D.C. shunt motor, under the conditions of maximum power, the current in the
armature will be
(a) almost negligible
(b) rated full-load current
(c) less than full-load current
(d) more than full-load current
Ans: d
24. These days D.C. motors are widely used in
(a) pumping sets
(b) air compressors
(c) electric traction
(d) machine shops
Ans: c
25. By looking at which part of the motor, it can be easily confirmed that a particular
motor is D.C. motor?
(a) Frame
(b) Shaft
(c) Commutator
(d) Stator
Ans: c
26. In which of the following applications D.C. series motor is invariably tried?
(a) Starter for a car
(b) Drive for a water pump
(c) Fan motor
(d) Motor operation in A.C. or D.C.
Ans: a
27. In D.C. machines fractional pitch winding is used
(a) to improve cooling
(b) to reduce copper losses
(c) to increase the generated e.m.f.
(d) to reduce the sparking
Ans: d
28. A three point starter is considered suitable for
(a) shunt motors
(b) shunt as well as compound motors
(c) shunt, compound and series motors
(d) all D.C. motors
Ans: b
29. In case-the conditions for maximum power for a D.C. motor are established, the
efficiency of the motor will be
(a) 100%
(b) around 90%
(c) anywhere between 75% and 90%
(d) less than 50%
Ans: d
30. The ratio of starting torque to full-load torque is least in case of
(a) series motors
(b) shunt motors
(c) compound motors
(d) none of the above
Ans: b
32. In D.C. motor which of the following can sustain the maximum temperature rise?
(a) Slip rings
(b) Commutator
(c) Field winding
(d) Armature winding
Ans: c
33. Which of the following law/rule can he used to determine the direction of rotation of
D.C. motor ?
(a) Lenz's law
(b) Faraday's law
(c) Coloumb's law
(d) Fleming's left-hand rule
Ans: d
34. Which of the following load normally needs starting torque more than the rated
torque?
(a) Blowers
(b) Conveyors
(c) Air compressors
(d) Centrifugal pumps
Ans: b
35. The starting resistance of a D.C. motor is generally
(a) low
(b) around 500 Q
(c) 1000 Q
(d) infinitely large
Ans: a
36. The speed of a D.C. series motor is
(a) proportional to the armature current
(b) proportional to the square of the armature current
(c) proportional to field current
(d) inversely proportional to the armature current
Ans: d
37. In a D.C. series motor, if the armature current is reduced by 50%, the torque of the
motor will be equal
to
(a) 100% of the previous value
(b) 50% of the previous value
(c) 25% of the previous value
(d) 10% of the previous value
(e) none of the above
Ans: c
38. The current drawn by the armature of D.C. motor is directly proportional to
(a) the torque required
(b) the speed of the motor
(c) the voltage across the terminals
(d) none of the above
Ans: a
39. The power mentioned on the name plate of an electric motor indicates
(a) the power drawn in kW
(b) the power drawn in kVA
(c) the gross power
(d) the output power available at the shaft
Ans: d
40. Which D.C. motor has got maximum self loading property?
(a) Series motor
(b) Shunt motor
(c) Cumulatively compounded 'motor
(d) Differentially compounded motor
Ans: d
41. Which D.C. motor will be suitable alongwith flywheel for intermittent light and heavy
loads?
(a) Series motor
(b) Shunt motor
(c) Cumulatively compounded motor
(d) Differentially compounded motor
Ans: c
42. If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens
(a) nothing will happen to th£ motor
(b) this will make armature to take heavy current, possibly burning it
(c) this will result in excessive speed, possibly destroying armature due to excessive
centrifugal stresses (d) motor will run at very slow speed
Ans: c
43. D.C. series motors are used
(a) where load is constant
(b) where load changes frequently
(c) where constant operating speed is needed
(d) in none of the above situations.
Ans: d
44. For the same H.P. rating and full load speed, following motor has poor starting torque
(a) shunt
(b) series
(c) differentially compounded
(d) cumulativelyc'ompounded
Ans: c
45. In case of conductively compensated D.C. series motors, the compensating winding is
provided
(a) as separately wound unit
(6) in parallel with armature winding
(c) in series with armature winding
(d) in parallel with field winding
Ans: c
46. Sparking at the commutator of a D.C. motor may result in
(a) damage to commutator segments
(b) damage to commutator insulation
(c) increased power consumption
(d) all of the above
Ans: d
47. Which of the following motor is preferred for operation in highly explosive
atmosphere ?
(a) Series motor
(b) Shunt motor
(c) Air motor
(d) Battery operated motor
Ans: c
48. If the supply voltage for a D.C. motor is increased, which of the following will decrease
?
(a) Starting torque
(b) Operating speed
(c) Full-load current
(d) All of the above
Ans: c
49. Which one of the following is not the function of pole shoes in a D.C. machine ?
(a) To reduce eddy current loss
(b) To support the field coils
(c) To spread out flux for better unifor-mity
(d) To reduce the reluctance of the mag-netic path
Ans: a
50. The mechanical power developed by a shunt motor will be maximum when the ratio
of back e.m.f. to applied voltage is
(a) 4.0
(b) 2.0
(c) 1.0
(d) 0.5
Ans: d

Answer :

51. The condition for maximum power in case of D.C. motor is
(a) back e.m.f. = 2 x supply voltage
(b) back e.m.f. = | x supply voltage
(c) supply voltage = | x back e.m.f.
(d) supply voltage = back e.m.f.
Ans: b
52. For which of the following applications a D.C. motor is preferred over an A.C. motor ?
(a) Low speed operation
(b) High speed operation
(c) Variable speed operation
(d) Fixed speed operation
Ans: c
53. In D.C. machines the residual magnetism is of the order of
(a) 2 to 3 per cent
(6) 10 to 15 per cent
(c) 20 to 25 per cent
(d) 50 to 75 per cent
Ans: a
54. Which D.C. motor is generally preferred for cranes and hoists ?
(a) Series motor
(b) Shunt motor
(c) Cumulatively compounded motor
(d) Differentially compounded motor
Ans: a
55. Three point starter can be used for
(a) series motor only
(b) shunt motor only
(c) compound motor only
(d) both shunt and compound motor
Ans: d
56. Sparking, is discouraged in a D.C. motor because
(a) it increases the input power con-sumption
(b) commutator gets damaged
(c) both (a) and (b)
(d) none of the above
Ans: b
57. Speed control by Ward Leonard method gives uniform speed variation
(a) in one direction
(b) in both directions
(c) below normal speed only
(d) above normal speed only.
Ans: b
58. Flywheel is used with D.C. compound motor to reduce the peak demand by the motor,
compound motor will have
to be
(a) level compounded
(b) under compounded
(c) cumulatively compounded
(d) differentially compounded
Ans: c
59. Following motor is used where high starting torque and wide speed range control is
required.
(a) Single phase capacitor start
(b) Induction motor
(c) Synchronous motor
(d) D.C. motor
(e) None of the above
Ans: d
60. In a differentially compounded D.C. motor, if shunt field suddenly opens
(a) the motor will first stop and then run in opposite direction as series motor
(b) the motor will work as series motor and run at slow speed in the same direction
(c) the motor will work as series motor and run at high speed in the same direction
(d) the motor will not work and come to stop
Ans: a
61. Which of the following motor has the poorest speed regulation ?
(a) Shunt motor
(b) Series motor
(c) Differential compound motor
(d) Cumulative compound motor
Ans: b
62. Buses, trains, trolleys, hoists, cranes require high starting torque and therefore make
use of
(a) D.C. series motor
(b) D.C. shunt motor
(c) induction motor
(d) all of above motors
Ans: a
63. As -the load is increased the speed of D.C. shunt motor will
(a) reduce slightly
(b) increase slightly
(c) increase proportionately
(d) remains unchanged
Ans: a
64. The armature torque of the D.C. shunt motor is proportional to
(a) field flux only
(b) armature current only
(c) both (a) and (b)
(d) none of the above
Ans: b
65. Which of the following method of speed control of D.C. machine will offer minimum
efficiency ?
(a) Voltage control method
(b) Field control method
(c) Armature control method
(d) All above methods
Ans: c
66. Usually wide and sensitive speed control is desired in case of
(a) centrifugal pumps
(b) elevators
(c) steel rolling mills
(d) colliery winders
Ans: d
67. The speed of a motor falls from 1100 r.p.m. at no-load to 1050 r.p.m. at rated load. The
speed regulation of the motor is
(a) 2.36%
(6) 4.76%
(c) 6.77%
(d) 8.84%
Ans: b
68. The armature voltage control of D.C. motor provides
(a) constant torque drive
(b) constant voltage drive
(c) constant current drive
(d) none of the above
Ans: a
69. As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a
heavy current from flowing though the armature circuit
(a) a resistance is connected in series with armature
(b) a resistance is connected parallel to the armature
(c) armature is temporarily open circuited
(d) a high value resistor is connected across the field winding
Ans: a
70. The speed of a D.C. shunt motor can be increased by
(a) increasing the resistance in armature circuit
(b) increasing the resistance in field circuit
(c) reducing the resistance in the field circuit
(d) reducing the resistance in the armature circuit
Ans: b
71. If I2 be the armature current, then speed of a D.C. shunt motor is
(a) independent of Ia
(b) proportional to la
(c) varies as (Ia)
(d) varies as la
Ans: a
72. In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed
by the motor will
(a) remain unchanged
(6) reduce to one-fourth value
(c) increase four folds
(d) be doubled
Ans: a
73. At the instant of starting when a D.C. motor is put on supply, it behaves like
(a) a highly resistive circuit
(6) a low resistance circuit
(c) a capacitive circuit
(d) none of the above
Ans: b
74. The speed of a D.C. motor can be varied by varying
(a) field current
(b) applied voltage
(c) resistance in series with armature
(d) any of the above
Ans: d
75. Which one of the following is not necessarily the advantage of D.C. motors over A.C.
motors ?
(a) Low cost
(b) Wide speed range
(c) Stability
(d) High starting torque.
Ans: a
76. For a D.C. shunt motor if the excitation is changed
(a) torque will remain constant
(b) torque will change but power will remain constant
(c) torque and power both will change
(d) torque, power and speed, all will change
Ans: b
77. Which motor has the poorest speed control?
(a) Differentially compounded motor
(b) Cumulatively compounded motor
(c) Shunt motor
(d) Series motor
Ans: d
78. The plugging gives the
(a) zero torque braking
(b) smallest torque braking
(c) highest torque braking
(d) none of the above
Ans: c
79. The armature voltage control of D.C. motor provides
(a) constant voltage drive
(b) constant current drive
(c) constant torque drive
(d) none of the above
Ans: c
80. If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient
temperature, then the motor
(a) of lower H.P. should be selected
(6) of higher H.P. should be selected
(c) can be used for 50°C ambient temperature also
(d) is to be derated by a factor recom-mended by manufacturer and select the next higher
H.P. motor
Ans: d
81. If the terminals of armature of D.C. motor are interchanged, this action will offer
following kind of braking
(o) regenerative
(b) plugging
(c) dynamic braking
(d) none of the above
(e) any of the above
Ans: b
82. Which of the following motors one will choose to drive the rotary compressor ?
(a) D.C. shunt motor
(b) D.C. series motor
(c) Universal motor
(d) Synchronous motor
Ans: d
83. If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will
(a) increase
(b) decrease
(c) remain same
(d) become zero
Ans: a
84. Why are the D.C. motors preferred for traction applications ?
(a) Torque and speed are inversely proportional to armature current
(b) Torque is proportional to armature current
(c) Torque is proportional to square root of armature current
(d) The speed is inversely proportional to the torque and the torque is proportional to
square of armature current
Ans: d
85. Which of the following motors is usually used in house-hold refrigerators ?
(a) D.C. shunt motor
(b) D.C. series motor
(c) Single phase induction motor (split phase start or induction run motor)
(d) Reluctance motor
(e) Synchronous motor
Ans: c
86. Which of the following motors is most suitable for signalling devices and many kinds
of timers ?
(a) D.C. shunt motor
(b) D.C. series motor
(c) Induction motor
(d) Reluctance motor
Ans: d
87. Which motor should not be started on no-load ?
(a) Series motor
(b) Shunt motor
(c) Cumulatively compounded motor
(d) Differentially compounded motor.
Ans: a
88. Ward-Leonard control is basically a
(a) voltage control method
(b) field divertor method
(c) field control method
(d) armature resistance control method
Ans: a
89. For constant torque drive which speed control method is preferred ?
(a) Field control
(b) Armature voltage control
(c) Shunt armature control
(d) Mechanical loading system
Ans: b
90. In Ward-Leonard control the lower limit of speed is imposed by
(a) residual magnetism of the generator
(b) core losses of motor
(c) mechanical losses of motor and gen¬erator together
(d) all of the above
Ans: a
91. The main disadvantage of the Ward-Leonard control method is
(a) high initial cost
(b) high maintenance cost
(c) low efficiency at Hght loads
(d) all of the above
Ans: d
92. Regenerative method of braking is based on that
(a) back e.m.f. is less than the applied voltage
(b) back e.m.f. is equal to the applied voltage
(c) back e.m.f. of rotor is more than the applied voltage
(d) none of the above
Ans: b
93. The hysteresis loss in a D.C. machine least depends on
(a) Frequency of magnetic reversals
(b) Maximum value of flux density
(c) Volume and grade of iron
(d) Rate of flow of ventilating air
Ans: d
94. In a D.C. generator all of the following could be the effects of iron losses except
(a) Loss of efficiency
(b) Excessive heating of core
(c) Increase in terminal voltage
(d) Rise in temperature of ventilating air
Ans: c
95. The losses occurring in a D.C. generator are given below. Which loss is likely to have
highest proportion at rated load of the generator ?
(a) hysteresis loss
(b) field copper loss
(c) armature copper loss
(d) eddy current loss
Ans: c
96. Which of the following loss in a D.C. generator varies significantly with the load
current ?
(a) Field copper loss
(b) Windage loss
(c) Armature copper loss
(d) None of the above
Ans: c
97. Torque developed by a D.C. motor depends upon
(a) magnetic field
(b) active length of the conductor
(c) current flow through the conductors
(d) number of conductors
(e) radius of armature
(f) all above factors
Ans: f
98. D.C. shunt motors are used for driving
(a) trains
(b) cranes
(c) hoists
(d) machine tools
Ans: d
99. In a manual shunt motor starter
(a) over load relay is connected in series and no volt relay in parallel with the load
(6) over load relay is connected in paral¬lel and no volt relay in series with the load
(c) over load relay and no volt relay are both connected in series with the load
(d) over load relay and no volt relay are both connected in parallel with the load
Ans: a
100. Which of the following steps is likely to result in reduction of hysteresis loss in a D.C.
generator ?
(a) Providing laminations in armature core
(b) Providing laminations in stator
(c) Using non-magnetic material for frame
(d) Using material of low hysteresis co-efficient for armature core material
Ans: d

Answer :

101. Which of the following loss in a D.C. generator is dissipated in the form of heat?
(a) Mechanical loss
(b) Core loss
(c) Copper loss
(d) All of the above
Ans: d
102. Which of the following losses are significantly reduced by laminating the core of a
D.C. generator ?
(a) Hysteresis losses
(b) Eddy current losses
(c) Copper losses
(d) Windage losses
Ans: b
103. The total losses in a well designed D.C. generator of 10 kW will be nearly
(a) 100 W
(b) 500 W
(c) 1000 W
(d) 1500 W
Ans: b
104. The condition for maximum efficiency for a D.C. generator is
(a) eddy current losses = stray losses
(b) hysteresis losses = eddy current losses
(c) copper losses = 0
(d) variable losses = constant losses
Ans: d
105. D.C. generators are normally designed for maximum efficiency around
(a) full-load
(b) rated r.p.m.
(c) rated voltage
(d) all of the above
Ans: a
106. In a D.C. generator, the iron losses mainly take place in
(a) yoke
(b) commutator
(c) armature conductors
(d) armature rotor
Ans: d
107. D.C. generators are installed near the load centres to reduce
(a) iron losses
(b) line losses
(c) sparking
(d) corona losses
Ans: b
108. The purpose of retardation test on D.C. shunt machines is to find out
(a) stray losses
(b) eddy current losses
(c) field copper losses
(d) windage losses
Ans: a
109. Which of the following tests will be suitable for testing two similar D.C. series motors
of large capacity ?
(a) Swinburne's test
(b) Hopkinson's test
(c) Field test
(d) Brake test
Ans: c
110. Hopkinson's test on D.C. machines is conducted at
(a) no-load
(b) part load
(c) full-load
(d) overload
Ans: c
111. During rheostat braking of D.C. series motors
(a) motor is run as a generator
(b) motor is reversed in direction
(c) motor is run at reduced speed
Ans: a
112. For which types of D.C. motor, dynamic braking is generally used ?
(a) Shunt motors
(b) Series motors
(c) Compound motors
(d) All of the above
Ans: d
113. Which method of braking is generally used in elevators ?
(a) Plugging
(b) Regenerative braking
(c) Rheostatic braking
(d) None of the above
Ans: a
114. In variable speed motor
(a) a stronger commutating field is needed at low speed than at high speed
(b) a weaker commutating field is needed at low speed than at high speed
(c) same commutating field is needed at low speed than at high speed
(d) none of the above is correct
Ans: b
115. When the armature of a D.C. motor rotates, e.m.f. induced is
(a) self-induced e.m.f.
(b) mutually induced e.m.f.
(c) back e.m.f.
(d) none of the above
Ans: c
116. Where D.C. motor of H.P. 12 or more requires frequent starting, stopping, reversing
and speed control
(a) drum type controller is used
(b) three point starter is used
(c) four point starter is used
(d) all above can be used
Ans: a
117. If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens
(a) this will make armature to take heavy current, possibly burning it
(6) this will result in excessive speed, possibly destroying armature due to excessive
centrifugal stresses
(c) nothing will happen to motor
(d) motor will come to stop
Ans: a
118. D.C. motor is to drive a load which has certain minimum value for most of the time
and some peak value for short
duration. We will select the
(a) series motor
(b) shunt motor
(c) compound motor
(d) any of the above
Ans: a
119. D.C. motor is to a drive a load which is almost nil for certain part of the load cycle
and peak value for short duration. We will select this
(a) series motor
(b) shunt motor
(c) compound motor
(d) any of the above
Ans: c
120. Which D.C. motor has got maximum self relieving property ?
(a) Series motor
(6) Shunt motor
(c) Cumulatively compounded motor
(d) Differentially compounded motor
Ans: a
121. In the D.C. motor the iron losses occur in
(a) the field
(b) the armature
(c) the brushes
(d) the commutator
Ans: b
122. The speed of a D.C. shunt motor is required to be more than full load speed. This is
possible by
(a) reducing the field current
(b) decreasing the armature current
(c) increasing the armature current
(d) increasing the excitation current
(e) none of the above methods
Ans: a
123. One D.C. motor drives another D.C. motor. The second D.C. motor when excited and
driven
(a) runs as a generator
(b) does not run as a generator
(c) also runs as a motor comes to stop after sometime
Ans: a

Related questions

Description : DC GENERATORS MCQ

Last Answer : 101. Wave winding is composed of (a) any even number of conductors (b) any odd number of conductors (c) that even number which is exact multiple of poles + 2 (d) that even number ... increase the field resistance (c) increase the speed of primemover (d) check armature insulation resis¬tance Ans: a

Description : MCQ on Motor Control Center

Last Answer : 1. MCC stands for ______ a. Motor Control Center b. Motor Control Cost c. Machine Components Center d. None of the above Answer : a. Motor Control Center 2. MCC contains _____ a. Fuse b. MCB c. ... a) Start the motor b) Accelerate the motor c) Decelerate the motor d) Stop the motor Answer : a

Description : State at least one function and the material used for the following parts of DC Motor.

Last Answer : Part Function Material Yoke -Provides mechanical support for poles -Acts as protecting cover for machine -Provides path for magnetic flux Cast Iron OR Cast Steel Field Winding - ... Pole core  Provides mechanical support to field winding. Cast Iron OR Cast Steel

Description : State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.

Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows:  1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine 

Description : DC motor gross torque example

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : DC motor brake test numerical

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Brake test on DC series motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : What would happen if a DC motor was supplied with AC ?

Last Answer : With three phase induction motor, humming and not rotate, but if single phase universal motor like air blower, home mixture, motor run on constant speed..speed variation not possible...

Description : State the function of following parts of DC motor : i) Yoke ii) Poles iii) Field winding iv) Commutator. 

Last Answer : Function : i) Yoke: The yoke serves the following two purposes. i) It supports the other components such as poles and provides mechanical protection for whole machine. ii) It forms a part of ... one pole to another and thus to help the motor to develop a continuous and unidirectional torque  

Description : State any four applications of DC shunt motor.

Last Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : Describe the reason of using dc series motor for electric trains.

Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor :  (A) can be operated in first quadrant (B) ... in first & second quadrants (C) can be operated in first & fourth quadrants (D) cannot be operated

Last Answer : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor : can be operated in first & fourth quadrants

Description : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :

Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Description : The function of a brush and commutator arrangement in a dc motor is to  (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking

Last Answer : The function of a brush and commutator arrangement in a dc motor is to produce unidirectional torque

Description : In a DC motor, it is important to place the brushes along ______ A) Magnetic Neutral Axis B) Normal Geometric Axis C) Nominal Geometric Axis D) None of these

Last Answer : In a DC motor, it is important to place the brushes along Magnetic Neutral Axis

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians (A) Armature amp-conductors × (θ/360o) (B) Armature amp-turns × (θ/360o) (C) Armature amp-conductors × (1/4 - θ/360o) (D) Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians Armature amp-conductors × (1/8 - θ/360o)

Description : In DC motor iron losses are occurred in?

Last Answer : In DC motor iron losses are occurred in the armature.

Description : Why a dc series motor has a high starting torque?

Last Answer : motor

Description : What is the principle of DC motor?

Last Answer : principle

Description : What are the speed control methods of dc motor?

Last Answer : Field control of DC motor Armature control of DC motor

Last Answer : Induction motor is a AC motor it is also known as asynchronous motor .

Description : Chopper controlled DC motor

Last Answer : Chopper controlled DC motor

Description : Armature control of DC motor

Last Answer : Armature control of DC motor

Description : Field control of DC motor

Last Answer : Field control of DC motor

Description : Separately Excited DC motor

Last Answer : Separately Excited DC motor

Description : TRANSMISSION AND DISTRIBUTION MCQ

Last Answer : 51. It is difficult to maintain oil filled cables. (a) Yes (b) No Ans: a 51. In capacitance grading a homogeneous dielectric is used. (a) Yes (b) No Ans: b 52. In congested areas where excavation is ... The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No Ans: b

Description : SYNCHRONOUS MOTORS MCQ

Last Answer : 101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then (a) the motor is said to be fully loaded (b) the torque ... square of the applied voltage (c) inversely proportional to applied voltage (d) none of the above Ans: a

Description : SINGLE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. After the starting winding of a single phase induction motor is disconnected from supply, it continues to run only on (a) running winding (b) rotor winding (c) field winding (d) compensating winding Ans: a ... motor is usually reduced by using (a) gearing (b) belts (c) brakes (d) chains Ans: a

Description : THREE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. Insertion of resistance in the stator of an induction motor (a) increases the load torque (b) decreases the starting torque (c) increases the starting torque (d) none of the above Ans: b

Description : TRANSFORMERS MCQ

Last Answer : 101. A shell-type transformer has (a) high eddy current losses (b) reduced magnetic leakage (c) negligibly hysteresis losses (d) none of the above Ans: b 102. A transformer can have regulation closer to zero (a ... (6) much smaller (c) much higher (d) somewhat smaller (e) none of the above Ans: c

Description : Power Maintenance MCQ

Last Answer : 1) Turbine pumps are used up to a suction head of ( b ) a. 1000 ft. c. 20 ft b. 100 ft d. 50 ft 2) The yard stick for provision of Electrical points in staff quarters can be changed by the Zonal railways ... is used for electrical fire ( b ) a. Water c. Foam b. Co2 & dry powder d. None of the above

Description : Explain the necessity of starter for D.C. motor. State various types of D.C. motor starter. 

Last Answer : Necessity of Starter for D.C. Motor: Armature current is given by equation Ia = (V−Eb)/Ra i) If the motor is at standstill or rest, back emf Eb is zero (as Eb= ZNP/(60A), at start speed N ... . Types of D.C. motor starters: i) Two point starter ii)Three point starter iii) Four point starter

Description : A d.c. motor can be looked upon as d.c. generator with the power flow?

Last Answer : A d.c. motor can be looked upon as d.c. generator with the power flow reversed.

Description : The Eb/V ratio of a d.c. motor is an indication of its?

Last Answer : The Eb/V ratio of a d.c. motor is an indication of its efficiency.

Description : The normal value of the armature resistance of a d.c. motor is?

Last Answer : The normal value of the armature resistance of a d.c. motor is 0.5.

Description : The counter e.m.f. of a d.c. motor?

Last Answer : The counter e.m.f. of a d.c. motor helps in energy conversion.

Description : In a d.c. motor, unidirectional torque is produced with the help of

Last Answer : Commutator provides unidirectional torque and pulsating dc

Last Answer : Series motor has got maximum self relieving property.

Description : D.C. motor is to a drive a load which is almost nil for certain part of the load cycle and peak value for short duration. We will select the?

Last Answer : D.C. motor is to a drive a load which is almost nil for certain part of the load cycle and peak value for short duration. We will select the compound motor.

Description : D.C. motor is to drive a load which has certain minimum value for most of the time and some peak value for short duration. We will select the?

Last Answer : DC motor mostly preferred is DC series motor becaus the load is continuous for a long time

Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Last Answer : When the armature of a D.C. motor rotates, e.m.f. induced is back e.m.f.

Last Answer : Shunt motors,  Series motors, Compound motors