Description : Which of the following brushes can be used for high values of current density ? (a) Metal graphite brushes (b) Hard carbon brushes (c) Electro-graphitic brushes (d) Natural graphite brushes
Last Answer : (a) Metal graphite brushes
Description : _____ brushes are fragile and cause excessive wear of commutator, (a) Natural graphite (b) Hard carbon (c) Electro graphitic (d) Metal graphite
Last Answer : (a) Natural graphite
Description : ________ has a lowrelative permeability and is used principally in field frames when cost is of primary importance and extra weight is not objectionable. (a) Cast steel (b) Aluminium (c) Soft steel (d) Cast iron
Last Answer : (d) Cast iron
Description : The forced oil and air circulation method is usual one for transformers of capacities (a) upto 5 MVA (b) upto 10 MVA (c) upto 20 MVA (d) 30 MVA upwards
Last Answer : (d) 30 MVA upwards
Description : By which of the following methods the temperature rise of windings and other parts may be determined ? (a) Thermometer method (6) Resistance method (c) Embedded temperature detector method (d) Any of the above
Last Answer : (d) Any of the above
Description : Which of the following methods is most accurate ? (a) Equivalent current method (b) Equivalent power method (c) Equivalent torque method (d) Method of average losses
Last Answer : (a) Equivalent current method
Description : Which of the following methods does not take into account the maximum temperature rise under variable load conditions ? (a) Equivalent power method (b) Equivalent current method (c) Method of average losses (d) Equivalent torque method
Last Answer : (c) Method of average losses
Description : By which of the following methods motor rating for variable load drives can be determined ? (a) Method of average losses (b) Equivalent current method (c) Equivalent torque method (d) Equivalent power method (e) All of the above.
Last Answer : (e) All of the above.
Description : Machines cooled by direct cooling method may be called (a) "supercharged" (b) "inner cooled" (c) "conductor cooled" (d) any of the above
Last Answer : (d) any of the above
Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above
Last Answer : (e) All of the above
Description : In D.C. machines, ir order to prevent excessive distortion of field form by the armature reaction, the field mmf must be made (a) equal to that of armature mmf (b) less in comparison with the arma¬ture mmf (c) large in comparison with the arma-ture mmf (d) none of the above
Last Answer : (c) large in comparison with the arma-ture mmf
Description : In D.C. machines the number of slots per pole usually lies (a) between 2 to 4 (b) between 6 to 8 (c) between 9 to 16 (d) between 20 to 30
Last Answer : (c) between 9 to 16
Description : In D.C. machines the usual limit of slot pitch is (a) between 5 to 10 mm (b) between 10 to 15 mm (c) between 15 to 20 mm (d) between 25 to 35 mm
Last Answer : (d) between 25 to 35 mm
Description : The operation of a D.C. machine with large air gap lengths is comparatively (a) quiet (b) noisy (c) either of the above (d) none of the above
Last Answer : (a) quiet
Description : In D.C. machines, the ____ in field mmf results in increase in size and cost of machines. (a) increase (b) decrease (c) either of the above (d) none of the above
Last Answer : (a) increase
Description : D.C. machines designed with a large value of air gap length have (a) worst, ventilation (b) poor ventilation (c) better ventilation (d) none of the above
Last Answer : (c) better ventilation
Description : In D.C. machines the width of the duct is usually (a) 4 mm (b) 6 mm (c) 8 mm (d) 10 mm
Last Answer : (d) 10 mm
Description : In a D.C. machine, the value of peripheral speed should not, normally, exceed (a) 10 m/s (b) 20 m/s (c) 30 m/s (d) 40 m/s
Last Answer : (c) 30 m/s
Description : In a D.C. machine the current per brush arm should not be more than (a) 100 A (6) 200 A (e) 300 A (d) 400 A
Last Answer : (d) 400 A
Description : In a D.C. machine the number of brush arms is _____ the number of poles. (a) less than (b) equal to (c) greater than (d) none of the above
Last Answer : (b) equal to
Description : The weight of copper of both armature and field windings decreases with _____ in number of poles. (a) increase (b) decrease (c) either of the above (d) none of the above
Description : Which of the following problem arises in D.C. motors which are fed from thyristor bridge circuits ? (a) Increased I R losses (b) Increased core losses (c) Poor commutation (d) Change in motor parameters (e) All of the above
Description : is usually used for brush rockers (a) Mild steel (b) Copper (c) Aluminium (d) Cast-iron
Last Answer : (d) Cast-iron
Description : The laminations of the armature of a D.C. machine are usually _____ thick. (a) 0.1 to 0.2 mm (b) 0.2 to 0.3 mm (c) 0.3 to 0.4 mm (d) 0.4 to 0.5 mm
Last Answer : (d) 0.4 to 0.5 mm
Description : The stator of a D.C. machine comprises of (a) main poles (6) interpoles (c) frame (d) all of the above
Last Answer : (d) all of the above
Description : D.C. servomotors are used in (a) purely D.C. control systems (6) purely AC. control systems (c) both D.C. and AC. control systems (d) none of the above
Last Answer : (a) purely D.C. control systems
Description : Which of the following in an application of D.C. motors? (a) Traction (b) Drives for process industry (c) Battery driven vehicles (d) Automatic control (e) All of the above
Description : The surge phenomenon is particularly important in case of (a) low voltage transformers (b) medium voltage transformers (c) high voltage transformers (d) any of the above
Last Answer : (c) high voltage transformers
Description : The cylindrical windings using circular conductors are used for current rating of (a) upto 20 A (b) upto 40 A (c) upto 60 A (d) upto 80 A
Last Answer : (d) upto 80 A
Description : The insulation between windings and grounded core and the insulation between the windings of the same phase is called (a) minor insulation (b) major insulation (c) either of the above (d) none of the above
Last Answer : (b) major insulation
Description : A practical formula for determining the thickness of insulation between low voltage and high voltage windings is (a) 1 + 0.2 kVmm (6) 2 + 0.5 kVmm (c) 4 + 0.7 kV mm (d) 5 + 0.9 kV mm
Last Answer : (d) 5 + 0.9 kV mm
Description : Which of the following is the basic consideration in the design of insulation ? (a) Electrical considerations (b) Mechanical considerations (c) Thermal considerations (d) All of the above
Last Answer : (d) All of the above
Description : The high voltage winding is usually which of the following type ? (a) Cylindrical winding with circular conductors (b) Cross-over winding with either circular or small rectangular conductors (c) Continuous disc type winding with rectangular conductors (d) All of the above types
Last Answer : (d) All of the above types
Description : A current density of _____ is ilsed for large power transformers with forced circulation of oil or with water cooling coils (a) 1.5 to 2.5 A/mm2 (b) 3.5 to 4.5 A/mm2 (c) 4.0 to 5.0 A/mm2 (d) 5.4 to 6.2 A/mm2
Last Answer : (d) 5.4 to 6.2 A/mm2
Description : For large power transformers, self oil cooled type or air blast type which of the following values of current density may be used ? (a) 1.0 to 1.2 A/mm2 (b) 1.5 to 2.0 A/mm2 (c) 2.2 to 3.2 A/mm2 (d) 3.2 to 4.2 A/mm2
Last Answer : (c) 2.2 to 3.2 A/mm2
Description : For 275 kV transformers, using cold rolled grain oriented steel, which of the following values of flux density may be used? (a) 1.0 Wb/m2 (b) 1.1 Wb/m2 (c) 1.3 Wb/m2 (d) 1.6 Wb/m2 (e) None of the above
Last Answer : (d) 1.6 Wb/m2
Description : The usual values of maximum flux densities for distribution transformers using hot rolled silicon steel are (a) 0.5 to 0.8 Wb/m2 (b) 0.8 to 1.0 Wb/m2 (c) 1.1 to 1.35 Wb/m2 (d) 1.4 to 1.8 Wb/m2
Last Answer : (c) 1.1 to 1.35 Wb/m2
Description : D.C. windings are (a) sometimes 2-layer type (b) never 2-layer type (c) always 2-layer type (d) none of the above
Last Answer : (c) always 2-layer type
Description : The voltage control in electric supply networks in required on account of which of the following reasons ? (a) Adjustment of voltage at consumers premises within statutory limits (b) Control of ... daily and seasonal voltage variations in accordance with variations of load (d) All of the above
Description : The flash point of transformer oil should be higher than (a) 40°C (b) 60°C (c) 80°C (d) 104°C
Last Answer : (d) 104°C
Description : Transformers with a capacity of upto _____ have a cooling radiator system with natural cooling (a) 2 MVA (b) 5 MVA (c) 7.5 MVA (d) 10 MVA
Last Answer : (d) 10 MVA
Description : The heat dissipating capability of transformers of ratings higher than 30 kVA in increased by providing which of the following ? (a) Corrugations (b) Fins (c) Tubes (d) Radiator tanks (e) All of the above
Description : Disc windings are primarily used in (a) short capacity transformers (b) medium capacity transformers (c) high capacity transformers (d) any of the above
Last Answer : (c) high capacity transformers
Description : Multi-layer helical windings are commonly used in the transformers as high voltage windings (a) upto 20 kV (b) upto 50 kV (c) upto 80 kV (d) for 110 kV and above
Last Answer : (d) for 110 kV and above
Description : Helical windings are used in (a) distribution transformers (b) power transformers (c) shell type transformers (d) none of the above
Last Answer : (b) power transformers
Description : Cylindrical windings using circular conductors, employed in transformers, are (a) single layered (b) double layered (c) multi-layered (d) none of the above
Last Answer : (c) multi-layered
Description : The cold rolled grain oriented steel has ______ permeability in the direction of the grain orientation. (a) minimum (b) maximum (c) nil (d) none of the above
Last Answer : (b) maximum
Description : Yokes with rectangular cross-section are used for (a) small capacity transformers (b) medium capacity transformers (c) large capacity transformers (d) any of the above
Last Answer : (a) small capacity transformers
Description : In transformers using hot rolled steel, the cross-section of the yoke is made about _____ greater than that of the core (a) 5 percent (b) 10 percent (c) 15 percent (d) 30 percent (e) none of the above
Last Answer : (c) 15 percent
Description : Power transformers should be designed to have maximum efficiency (a) at one-fourth load (b) at one-half load (c) at or near full load (d) any of the above
Last Answer : (c) at or near full load