Which of the following methods is most accurate ?
(a) Equivalent current method
(b) Equivalent power method
(c) Equivalent torque method
(d) Method of average losses

1 Answer

Answer :

(a) Equivalent current method

Related questions

Description : Which of the following methods does not take into account the maximum temperature rise under variable load conditions ? (a) Equivalent power method (b) Equivalent current method (c) Method of average losses (d) Equivalent torque method

Last Answer : (c) Method of average losses

Description : By which of the following methods motor rating for variable load drives can be determined ? (a) Method of average losses (b) Equivalent current method (c) Equivalent torque method (d) Equivalent power method (e) All of the above.

Last Answer : (e) All of the above.

Description : By which of the following methods the temperature rise of windings and other parts may be determined ? (a) Thermometer method (6) Resistance method (c) Embedded temperature detector method (d) Any of the above

Last Answer : (d) Any of the above

Description : Which of the following problem arises in D.C. motors which are fed from thyristor bridge circuits ? (a) Increased I R losses (b) Increased core losses (c) Poor commutation (d) Change in motor parameters (e) All of the above

Last Answer : (e) All of the above

Description : cooling is the process of dissipating the armature and field winding losses to a cooling medium circulating within the winding insulation wall (a) Direct (b) Indirect (c) Conventional (d) Any ofthe above

Last Answer : (a) Direct

Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above

Last Answer : (e) All of the above

Description : Which ofthe following methods is used for air cooling of turbo-alternators ? (a) One sided axial ventilation (b) Two sided axial ventilation (c) Multiple inlet system (d) All ofthe above

Last Answer : (d) All ofthe above

Description : A current density of _____ is ilsed for large power transformers with forced circulation of oil or with water cooling coils (a) 1.5 to 2.5 A/mm2 (b) 3.5 to 4.5 A/mm2 (c) 4.0 to 5.0 A/mm2 (d) 5.4 to 6.2 A/mm2

Last Answer : (d) 5.4 to 6.2 A/mm2

Description : For large power transformers, self oil cooled type or air blast type which of the following values of current density may be used ? (a) 1.0 to 1.2 A/mm2 (b) 1.5 to 2.0 A/mm2 (c) 2.2 to 3.2 A/mm2 (d) 3.2 to 4.2 A/mm2

Last Answer : (c) 2.2 to 3.2 A/mm2

Description : ________ is the common method of applying brushes to the commntator. (a) Radial (b) Trailing (c) Reaction (d) All of the above

Last Answer : (d) All of the above

Description : The forced oil and air circulation method is usual one for transformers of capacities (a) upto 5 MVA (b) upto 10 MVA (c) upto 20 MVA (d) 30 MVA upwards

Last Answer : (d) 30 MVA upwards

Description : Machines cooled by direct cooling method may be called (a) "supercharged" (b) "inner cooled" (c) "conductor cooled" (d) any of the above

Last Answer : (d) any of the above

Description : In a D.C. machine the current per brush arm should not be more than (a) 100 A (6) 200 A (e) 300 A (d) 400 A

Last Answer : (d) 400 A

Description : Which of the following brushes can be used for high values of current density ? (a) Metal graphite brushes (b) Hard carbon brushes (c) Electro-graphitic brushes (d) Natural graphite brushes

Last Answer : (a) Metal graphite brushes

Description : The cylindrical windings using circular conductors are used for current rating of (a) upto 20 A (b) upto 40 A (c) upto 60 A (d) upto 80 A

Last Answer : (d) upto 80 A

Description : The value of exciting or magnetizing current depends upon which of the following factors ? (a) Total m.m.f. required (b) The number of turns in the exciting winding (c) The way in which the winding is distributed (d) All of the above

Last Answer : (d) All of the above

Description : The slot leakage can be calculated by making which of the following assumptions ? (a) The current in the slot conductors is uniformly distributed over their cross-section (b) The leakage path is straight ... is only considered. The reluctance of iron paths is assumed as zero (d) All of the above

Last Answer : (d) All of the above

Description : The voltage control in electric supply networks in required on account of which of the following reasons ? (a) Adjustment of voltage at consumers premises within statutory limits (b) Control of ... daily and seasonal voltage variations in accordance with variations of load (d) All of the above

Last Answer : (d) All of the above

Description : Helical windings are used in (a) distribution transformers (b) power transformers (c) shell type transformers (d) none of the above

Last Answer : (b) power transformers

Description : Power transformers should be designed to have maximum efficiency (a) at one-fourth load (b) at one-half load (c) at or near full load (d) any of the above

Last Answer : (c) at or near full load

Description : Power transformers have rating (a) equal to 50 kVA (6) equal to 100 kVA (c) above 200 kVA (d) none of the above

Last Answer : (c) above 200 kVA

Description : On which of the following variables heat convected depends ? (a) Power density (b) Temperature difference between heated surface and coolant (c) Thermal resistivity, density, specific heat (d) Gravitational constant (e) All ofthe above

Last Answer : (e) All ofthe above

Description : Electrical machines having power outputs ranging from a few kW upto approximately 250 kW may be classified as (a) small size machines (b) medium size machines (c) large size machines (d) any ofthe above

Last Answer : (b) medium size machines

Description : Electrical machines having a power output upto about 750 W may be called_______machines. (a) small size (b) medium size (c) large size (d) any of the above

Last Answer : (a) small size

Description : The length cf air gap to be provided in ______ is primarily determined by power factor consideration. (a) d.c. series motor . (b) d.c. shunt motor (c) induction motor (d) synchronous motor

Last Answer : (c) induction motor

Description : In induction motors, the length of air gap in kept as small as mechanically possible is order to have (a) low power factor (b) high power factor (c) high over load capacity (d) any of the above

Last Answer : (b) high power factor

Description : impose limitation on design. (a) Saturation (b) Temperature rise (c) Efficiency (d) Power factor (e) All above

Last Answer : (e) All above

Description : In D.C. machines the number of slots per pole usually lies (a) between 2 to 4 (b) between 6 to 8 (c) between 9 to 16 (d) between 20 to 30

Last Answer : (c) between 9 to 16

Description : In D.C. machines the usual limit of slot pitch is (a) between 5 to 10 mm (b) between 10 to 15 mm (c) between 15 to 20 mm (d) between 25 to 35 mm

Last Answer : (d) between 25 to 35 mm

Description : The operation of a D.C. machine with large air gap lengths is comparatively (a) quiet (b) noisy (c) either of the above (d) none of the above

Last Answer : (a) quiet

Description : In D.C. machines, the ____ in field mmf results in increase in size and cost of machines. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : In D.C. machines, ir order to prevent excessive distortion of field form by the armature reaction, the field mmf must be made (a) equal to that of armature mmf (b) less in comparison with the arma¬ture mmf (c) large in comparison with the arma-ture mmf (d) none of the above

Last Answer : (c) large in comparison with the arma-ture mmf

Description : D.C. machines designed with a large value of air gap length have (a) worst, ventilation (b) poor ventilation (c) better ventilation (d) none of the above

Last Answer : (c) better ventilation

Description : In D.C. machines the width of the duct is usually (a) 4 mm (b) 6 mm (c) 8 mm (d) 10 mm

Last Answer : (d) 10 mm

Description : In a D.C. machine, the value of peripheral speed should not, normally, exceed (a) 10 m/s (b) 20 m/s (c) 30 m/s (d) 40 m/s

Last Answer : (c) 30 m/s

Description : In a D.C. machine the number of brush arms is _____ the number of poles. (a) less than (b) equal to (c) greater than (d) none of the above

Last Answer : (b) equal to

Description : The weight of copper of both armature and field windings decreases with _____ in number of poles. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : _____ brushes are fragile and cause excessive wear of commutator, (a) Natural graphite (b) Hard carbon (c) Electro graphitic (d) Metal graphite

Last Answer : (a) Natural graphite

Description : is usually used for brush rockers (a) Mild steel (b) Copper (c) Aluminium (d) Cast-iron

Last Answer : (d) Cast-iron

Description : The laminations of the armature of a D.C. machine are usually _____ thick. (a) 0.1 to 0.2 mm (b) 0.2 to 0.3 mm (c) 0.3 to 0.4 mm (d) 0.4 to 0.5 mm

Last Answer : (d) 0.4 to 0.5 mm

Description : The stator of a D.C. machine comprises of (a) main poles (6) interpoles (c) frame (d) all of the above

Last Answer : (d) all of the above

Description : D.C. servomotors are used in (a) purely D.C. control systems (6) purely AC. control systems (c) both D.C. and AC. control systems (d) none of the above

Last Answer : (a) purely D.C. control systems

Description : Which of the following in an application of D.C. motors? (a) Traction (b) Drives for process industry (c) Battery driven vehicles (d) Automatic control (e) All of the above

Last Answer : (e) All of the above

Description : The surge phenomenon is particularly important in case of (a) low voltage transformers (b) medium voltage transformers (c) high voltage transformers (d) any of the above

Last Answer : (c) high voltage transformers

Description : The insulation between windings and grounded core and the insulation between the windings of the same phase is called (a) minor insulation (b) major insulation (c) either of the above (d) none of the above

Last Answer : (b) major insulation

Description : A practical formula for determining the thickness of insulation between low voltage and high voltage windings is (a) 1 + 0.2 kVmm (6) 2 + 0.5 kVmm (c) 4 + 0.7 kV mm (d) 5 + 0.9 kV mm

Last Answer : (d) 5 + 0.9 kV mm

Description : Which of the following is the basic consideration in the design of insulation ? (a) Electrical considerations (b) Mechanical considerations (c) Thermal considerations (d) All of the above

Last Answer : (d) All of the above

Description : The high voltage winding is usually which of the following type ? (a) Cylindrical winding with circular conductors (b) Cross-over winding with either circular or small rectangular conductors (c) Continuous disc type winding with rectangular conductors (d) All of the above types

Last Answer : (d) All of the above types

Description : For 275 kV transformers, using cold rolled grain oriented steel, which of the following values of flux density may be used? (a) 1.0 Wb/m2 (b) 1.1 Wb/m2 (c) 1.3 Wb/m2 (d) 1.6 Wb/m2 (e) None of the above

Last Answer : (d) 1.6 Wb/m2

Description : The usual values of maximum flux densities for distribution transformers using hot rolled silicon steel are (a) 0.5 to 0.8 Wb/m2 (b) 0.8 to 1.0 Wb/m2 (c) 1.1 to 1.35 Wb/m2 (d) 1.4 to 1.8 Wb/m2