What is the order of the characteristic equation of an armature controlled DC motor? 

(A) First order equation (B) Second order equation (C) Zero order equation (D) Third order equation 

1 Answer

Answer :

third order

Related questions

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : With the help of neat diagrams,explain the following methods of speed control in DC series motor. i) Field diverter method. ii) Armature diverter method.

Last Answer : (i) Field diverter method: - Resistance connected in parallel with field winding -By adjusting this resistance current can by diverted from field winding -Thus field current decreases and the speed can be ... decreased, the flux must increase and hence speed is decreased than the rated speed.

Description : Armature shunting method of speed control of dc shunt motor is preferred over annature resistance method due to:  (1) Better speed regulation (2) Less loss in external resistance (3) Simplicity in control circuit (4) Reduced cost of controller

Last Answer : Armature shunting method of speed control of dc shunt motor is preferred over annature resistance method due to: Better speed regulation.

Description : The torque produced by a DC motor armature is the product of the force acting at the armature surface multiplied by _____________. A. work done by the armature in one revolution B. effective ... arm at the center of rotation of the armature D. perpendicular distance to its center of rotation

Last Answer : Answer: D

Description : A series wound DC motor has its armature and field connected in series with a resistor. When the motor is disconnected from its power supply, this motor will exemplify __________. A. the ... the proper connections for an automatic strip heater C. a reversing controller circuit D. dynamic braking

Last Answer : Answer: D

Description : If the connections for the field and the armature on a DC motor are reversed, _____________. A. the motor will run as a generator B. the motor will not run C. the direction of rotation will be the same D. the direction of rotation will be reversed

Last Answer : Answer: C

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica

Last Answer : Answer: A

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : A short circuit in the armature of a DC motor will cause the motor to _____________. A. run fast B. hum when energized C. spark at the brushes D. fail to start

Last Answer : Answer: C

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator

Last Answer : Answer: B

Description : If you reverse both the field and the armature connections to a DC propulsion motor, _____________. A. the direction of motor rotation will change B. the brushes will become overheated C. a magnetic lock will occur in the motor D. the direction of motor rotation will remain the same

Last Answer : Answer: D

Description : The direction of rotation of a DC propulsion motor can be reversed by __________. A. reversing the field connections B. reversing the field and the armature connections C. wiring the field and armature in parallel D. wiring the field and armature in series

Last Answer : Answer: A

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C

Description : The counter EMF of a DC motor is maximum when the _________. A. motor is at rated speed B. armature is not turning C. motor is almost up to rated speed D. armature has just begun to turn

Last Answer : Answer: A

Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking

Last Answer : Answer: A

Description : The counter EMF produced in the windings of a DC motor is 'zero' when the ____________. A. armature has just begun to turn B. armature is not turning C. motor is almost up to rated speed D. motor is at rated speed

Last Answer : Answer: B

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : Armature reaction in a dc motor causes a shift of the neutral plane in which direction?

Last Answer : Opposite the rotation.

Description : As compared to shunt and compound DC motors, the series DC motor will have the highest torque because of its comparatively ____________ at the start. (A) Lower armature resistance. (B) Stronger series field. (C) Fewer series turns. (D) Larger armature current.

Last Answer : (D) Larger armature current.

Description : The torque, in a _____________is proportional to the square of the armature current (A) DC shunt motor (B) stepper motor (C) 2-phase servomotor (D) DC series motor

Last Answer : (D) DC series motor

Description : For a DC motor, what major component in addition to the field winding and the armature winding is necessary? w) a commutator x) a stator y) a battery z) a rotor

Last Answer : ANSWER: W -- A COMMUTATOR

Description : The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 ... .5 A from the same source will be  (A) 48.0% (B) 57.1% (C) 59.2% (D) 88.8%

Last Answer : The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 rpm drawing a current of 3.5 A from the same source will be 48.0%

Description : A step-down chopper, fed from a 120 volt DC source, operates a DC motor whose armature e.m.f. and armature resistance are 100 volt and 0.5Ω respectively. With the magnitude control ratio 0.6, the quadrant of operation DC motor is  (a) First (b) Second (c) Third (d) Fourth

Last Answer : A step-down chopper, fed from a 120 volt DC source, operates a DC motor whose armature e.m.f. and armature resistance are 100 volt and 0.5Ω respectively. With the magnitude control ratio 0.6, the quadrant of operation DC motor is First

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : Armature control of DC motor

Last Answer : Armature control of DC motor

Description : A separately excited dc motor is required to be controlled, from a 3-phase supply, for its operation in the first quadrant only. The most preferred converter would be  (a) 3-phase fully controlled ... converter with free wheel diode (c) 3-phase dual converter (d) 3-phase half wave converter 

Last Answer : A

Description : A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an _____________. A. rotor B. stator C. exciter D. armature

Last Answer : Answer: C

Last Answer : Functions of armature core: 1) Support the armature winding which is placed in its slots. 2) Rotate as driven by the prime mover (generator) or as per the torque produced (motor).  Hence ... magnetic path to increase the magnitude of induced emf for a certain MMF created by the field winding. 

Description : The supply both to field and armature circuits are disconnected simultaneously in a separately excited dc motor and it comes to a standstill in 5 sec. If the armature circuit of this motor is disconnected from supply with field ... rest in (1) 5 sec (2) 7 sec (3) 4 sec (4) A very long time  

Last Answer : 5 sec only.standstill time doesn't depend upon field excitation

Description : The number of parallel paths in armature winding of four pole wave winding connected dc machine having 22 coil sides is (1) 4 (2) 22 (3) 2 (4) 11 

Last Answer : Ans- Option (3) because wave winding always have 2 parallel paths

Description : A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is

Last Answer : A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is 40 V.

Description : Which of the following statements represents an application of a silicon controlled rectifier? A. To provide DC power for a main propulsion motor. B. For use as a voltage reference diode. C. For sensing flame in an automated burner. D. To eliminate power supply hum.

Last Answer : Answer: A

Description : A single-phase half-controlled rectifier is driving a separately excited dc motor. The dc motor has a back emf constant of 0.5 V/rpm. The armature current is 5 A without any ripple. The armature resistance is 2 Ohm. The ... of the motor will be  (A) 339 rpm (B) 359 rpm (C) 366 rpm (D) 386 rpm

Last Answer : 359

Description : Chopper controlled DC motor

Last Answer : Chopper controlled DC motor

Description : The frequency output of an operating alternator is controlled by the _____________. A. relative speed of the rotor poles B. number of turns of wire in the armature coil C. strength of the magnets used D. output voltage

Last Answer : Answer: A

Description : Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

Last Answer : Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature

Last Answer : Answer: B

Description : DC generator voltage is decreased by cutting _____________. A. in field resistance B. out field resistance C. in armature resistance D. out armature resistance

Last Answer : Answer: A

Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes

Last Answer : Answer: B

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : Armature cores in a DC generator are made of laminated steel sheets to _____________. A. fit the curvature of the frame B. increase the hysteresis effect C. reduce eddy current losses D. allow for easy assembly

Last Answer : Answer: C

Description : The purpose of DC generator brushes is to _____________. A. neutralize armature reaction B. conduct electric current to an outside circuit C. convert DC current to AC current D. provide excitation to a DC generator

Last Answer : Answer: B

Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes

Last Answer : Answer: B