An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the dropping of load by that alternator B. overspeeding of the vibrating alternator C. the alternator was operating out of synchronism D. flashover at the alternator collector rings

1 Answer

Answer :

Answer: C

Related questions

Description : Severe vibration, accompanied by flashover at the collector rings of an alternator operating in parallel, is a symptom of _____________. A. reverse current motorization B. loss of synchronism C. destructive overspeeding D. reversed polarity

Last Answer : Answer: B

Description : If a synchronous motor begins to vibrate severely and pull out of synchronism, the cause may be ____________. A. an overload B. an open in the field coils C. no exciter voltage D. all of the above

Last Answer : Answer: D

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : If three AC generators are operating in parallel, and one of them were to 'pull out' of synchronism with the other two generators, the ____________. A. normally operating AC generators will ... AC generators will overspeed and unload D. AC generator pulling out of synchronism will become motorized

Last Answer : Answer: B

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : The purpose of the reverse power relay, provided on a ship's service alternator panel, is to trip the circuit in the event of ______________. A. main circuit overload B. high power transfer C. generator overspeeding D. alternator motorization

Last Answer : Answer: D

Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.

Last Answer : Answer: D

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : When an alternator is to remain idle for even a few days _________________. A. lift the brushes and disconnect the pigtails B. insulate the collector rings with strips of cardboard C. energize the heater circuit D. open the equalizing bus disconnect switch

Last Answer : Answer: C

Description : A change in field excitation of an alternator operating in parallel will cause a change in its _____________. A. alternator frequency B. kilowatt load C. voltage output D. all of the above

Last Answer : Answer: C

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : If the energy input is significantly reduced to the prime mover of one shipboard alternator operating in parallel with others, that alternator will _____________. A. continue to operate at no load B. lose ... overspeed C. begin to motorize and then trip out D. slow down and operate at reduced load

Last Answer : Answer: C

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure

Last Answer : Answer: D

Description : The operating torque of the upper induction disc-type element, or timer element, of an AC reverse power relay is obtained from ____________. A. the main bus B. a separate battery source C. line voltage D. electromagnets

Last Answer : Answer: D

Description : The timer element found in a reverse power relay obtains its operating torque via _____________. A. line voltage B. the main bus C. electromagnets D. a separate battery source

Last Answer : Answer: C

Description : Why low forward power relay used in parallel to reverse power relay?

Last Answer : A small steam leak through CIES valves will keep the machine floating on to grid at low power. So even if turbine trip, relay picks up, there is no trip actually. So low forward power relay (0.54%) used to detect the condition. 

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : The current from the stator of an alternator is taken out to the external load circuit through (A) slip rings. (B) commutator segments. (C) solid connections. (D) carbon brushes.

Last Answer : (C) solid connections.

Description : In an A.C. generator, pitting of collector rings will cause __________. I. sparking II. Chattering A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: D

Description : Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST? A. Restart the tripped machine immediately. B. Strip the board ... circuits. C. Start the emergency generator. D. Transfer all vital loads to the emergency bus.

Last Answer : Answer: B

Description : A three-phase alternator is operating at 450 volts, 250 amps at 0.6 power factor. If the power factor increases to 0.8, the kw load potential will increase by _____________. A. 38.525 kw B. 116.91 kw C. 155.88 kw D. 194.85 kw

Last Answer : Answer: A

Description : Why do I sometimes feel my phone vibrate when it's not actually vibrating?

Last Answer : There’s actually a name (albeit an informal one) for this: phantom vibration syndrome. There’s also phantom ringing syndrome, fauxcellarm, ringxiety†but it’s all the same concept, and it’s pretty ... a researcher on the concept, in an interview with WebMD. "So, due to these

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A

Description : If the pointer of the synchroscope is rotating in the slow direction when you are preparing to parallel two alternators, the _____________. A. incoming machine is turning faster than the load alternator B ... alternator is ready to split D. incoming machine is beginning to pick up some of the load

Last Answer : Answer: B

Description : Chattering of the collector ring brushes on a generator may be remedied by _____________. A. lubricating brush holders B. reinsulating the brushes C. cleaning the collector rings D. increasing length of pigtail

Last Answer : Answer: C

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout

Last Answer : Answer: C

Description : Which of the following problems will occur if the circuit breaker of the incoming alternator is closed and it is 180° out of phase with the loaded alternator when paralleling? A. The rotor of the ... The rotor of the incoming alternator will stop. D. Both alternators will parallel 180° out of phase.

Last Answer : Answer: B

Description : Vibration measuring instruments are classified on the basis of ____________. (A) contact between the vibrating system and measuring instrument (B) the requirement of power source (C) method of measurements (D) all of the above

Last Answer : (D) all of the above

Description : How to make the vibration for message alert vibrate more on Nokia N97?

Last Answer : If no1 helped there , chances are no1 will help here . Thats not cause they don’t want to help , but maybe due to what you want isn’t something thats available. Best bet would be email nokia

Description : The principal of mode vibration can be given by A) Two masses vibrate at Different frequency and in same phase B) Two masses vibrate at Different frequency and in Different phase C) Two masses vibrate at same frequency and in Different phase D) Two masses vibrate at same frequency and in same phase

Last Answer : D) Two masses vibrate at same frequency and in same phase

Description : If the particle of a body vibrate along a circular arc, whose centre lies on the axis of the shaft then the body is said to have A) Transverse vibration B) Longitudinal vibration C) Torsional vibration D) None of the above

Last Answer : C) Torsional vibration

Description : When two masses vibrate at the same frequency and in phase, it is called a principal mode of vibration A. True B. False C. Does not depend on vibration D. None of the above

Last Answer : A. True

Description : When heavy rotating masses are connected by a shaft and equal and opposite torques are applied to these masses (rotors) A. The rotors vibrate torsionally in the same direction. B. The rotors vibrate torsionally ... on the axis of shaft which remains undisturbed by vibration. D. Both (B) and (C)

Last Answer : D. Both (B) and (C)

Description : Which of the listed conditions will occur if dirt and grease are allowed to accumulate between the commutator segments of a motor? A. A partial short circuit. B. A dead short circuit. C. Misalignment of the motor shaft. D. Overspeeding of the motor.

Last Answer : Answer: A

Description : Routine maintenance of a ship's service alternator should include ______________. A. changing the pedestal bearing insulation yearly B. megger testing of all rectifying diodes C. lubricating excitation slip rings D. periodic cleaning of the air filters or screens

Last Answer : Answer: D

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : In the illustrated circuit, the amplifier is connected in what basic configuration? EL-0022 A. common base B. reverse bias, negative feedback C. common emitter D. common collector

Last Answer : Answer: C

Description : In the illustration, the large battery and R(L) are in the circuit to ________. EL-0022 A. forward bias the emitter-base B. reverse bias the emitter-base C. forward bias the emitter/collector D. reverse bias the emitter/collector

Last Answer : Answer: D

Description : The device in figure 'B' shown in the illustration will conduct when the ____________. EL-0067 A. base-emitter is forward biased and the collector-base is reverse biased B. anode-cathode is forward ... is reversed biased D. terminal 1-2 is forward biased and the emitter-terminal 1 is reverse biased

Last Answer : Answer: B

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : I have a motorola krazer. How do I setup the phone to vibrate only. When someone calls in, the phone vibrates but then rings if I don't answer it. Also rings when a voicemail is left. How do I change the setting?

Last Answer : Without looking at a Motorola Phone in my hand, I can't recall the exact menu-steps to configure the settings; however, if the krazer is the same as past Motorola phones produced, you simply have to ... click the Volume Down button on the side of the handset until it's comlpetely off and on vibrate.

Description : The timer element of a reverse power relay cannot be energized unless _____________. A. the power flow is the same as the tripping direction B. the power flow is the opposite to the tripping direction C. the movement of the disk is damped by a permanent magnet D. one generator is motorized

Last Answer : Answer: A