Description : The minimum thickness of Metallising is
Last Answer : 115 micron
Description : Metallising is the process of spraying of …. on the surface prepared girder.
Last Answer : Zinc.. or ..Aluminium.
Description : Surface preparation for Metallising the abrasives used for final cleaning is a) Chilled iron grit G.24, as defined in BS : 2451 b) Washed salt free angular silica sand of mesh size 12 to 30 with a minimum of 40% retained on a 20 mesh c) either (a) or (b) * d) d) neither (a) or (b)
Last Answer : c) either (a) or (b) *
Description : Corrosion in Steel girder bridges may be prevented by : a) Protective coatings by painting b) Metallising c) Use of epoxy based paints d) All the above*
Last Answer : d) All the above*
Description : Thickness of Lining/Charge is kept? (i) 20 mm. (ii) 25 mm* (iii) 30 mm (iv) As decided by the site supervisor
Last Answer : (ii) 25 mm*
Description : In case of compaction of soil by sheep foot roller maximum thickness of layer should not exceed buy more than -------------- centimeter of length of their teeth a) 5 centimeter* b) 4 centimeter c) 3 centimeter d) 2 centimeter
Last Answer : a) 5 centimeter*
Description : Elcometer is used to measure the ……….. a) cross level b) Gauge c) Thickness of paint* d) All the above
Last Answer : c) Thickness of paint*
Description : The condition will be called as thin flange, when the flange thickness becomes less the: (a) 10mm (b) 12mm (c) 16mm* (d) 15mm
Last Answer : (c) 16mm*
Description : As per IRCA rules, the rejection limits for wheel flange thickness is - (a) 38mm (b) 25.4mm (c) 16mm* (d) 20 mm
Description : What is the full form of GMT a. Gross Million Tonnes* b. Gross minimum thickness c. Gross Maximum thickness d. None of above
Last Answer : a. Gross Million Tonnes*
Description : The average threshing outrun of a paddy in kg/hr is (A) 500 (B)650 (C)800 (D)1000
Last Answer : (B)650
Description : Formula for average service life of belt at a given speed is a) Life(hrs)= [ Belt length (mm)/ Total fatique rates]*100 b) Life(hrs)=[Total fatique rates / Belt length (mm)]*100 c) Life(hrs)=[Belt length (m)/ Total fatique rates]*100 d) None of the above
Last Answer : a) Life(hrs)= [ Belt length (mm)/ Total fatique rates]*100
Description : Peak hour demand of water is taken as ---------- times the average daily demand a)1.5 b)1.9 c)2.25* d)2.75
Last Answer : c)2.25*
Description : What is the most important requirement for the people of a flood hit area?
Last Answer : Inoculation against cholera
Description : If a material has identical properties in all directions, it is called (a) Elastic (b) Plastic (c) Isotropic (d) Homogeneous
Last Answer : (c) Isotropic
Description : Both noting and protest are compulsory in case of A. Foreign Bills B. Inland Bills C. Foreign as well as Inland Bills D. None of them
Last Answer : C. Foreign as well as Inland Bills
Description : Power tillers are popularly available in hp range of q. 6-12 hp r. 12-20 hp s. 1-6 hp t. 20-50 hp
Last Answer : q. 6-12 hp
Description : The commonly used power transmission system in ferti seed drills are: a) China-sprocket and gears b) Gears and belt pulleys c) Belt pulleys and cams d) Belt pulleys and chain sprocket
Last Answer : d) Belt pulleys and chain sprocket
Description : The upper safe noise level for machine operator is : a. 85db b. 100db c. 110db d. 115db
Last Answer : a. 85db
Description : In a precision planter the height of seed drop: A. Should be as close to be ground level as is possible. B. Should be at least 1 m from the ground level. C. Is not a factor to be considered? D. None of These
Last Answer : A. Should be as close to be ground level as is possible.
Description : ate of wear chain drive system a) Directly related to speed of chain b) Inversely related to size of sprocket of chain length c) Both (a) and (b) d) None of the above
Last Answer : c) Both (a) and (b)
Description : Loading capacity of chain drive system is based on a) Rate of wear b) Ultimate strength of chain material c) None of (a) and (b) d) Both (a) and (b)
Last Answer : a) Rate of wear
Description : which stage represents optimum conditions for tillage a) Sticky b) Plastic c) Friable ( crumbly ). d) Hard ( cemented )
Last Answer : c) Friable ( crumbly
Description : Norms for No. of seats at recommended level at Cat. E stn. is (a) 0.4 Ndb (b) 0.4 Nds* (c) 0.4 Nmax (d) 100 on each P.F.
Last Answer : (b) 0.4 Nds*
Description : Norms for No. of seats at recommended level at Cat. D stn. is (a) 0.4 Ndb (b) 0.4 Nds* (c) 0.4 Nmax (d) 100 on each P.F.
Description : Norms for No. of seats at recommended level at Cat. C stn. is (a) 0.4 Ndb (b) 0.4 Nds* (c) 0.4 Nmax (d) 100 on each P.F.
Description : Norms for No. of seats at recommended level at Cat. B stn. is (a) 0.4 Ndb * (b) 0.4 Nds (c) 0.4 Nmax (d) 100 on each P.F.
Last Answer : (a) 0.4 Ndb
Description : Norms for No. of seats at recommended level at Cat. A stn. is (a) 0.4 Ndb* (b) 0.4 Nds (c) 0.4 Nmax (d) 100 on each P.F.
Last Answer : (a) 0.4 Ndb*
Description : As per norms for desirable amenity as given to model station, the retiring rooms should be provided on stations classified as --- (a) A & B* (b) A,B & C (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : a) A & B*
Description : As per norms for desirable amenity as given to model station, the clock rooms should be provided on stations classified as --- (a) A & B * (b) A,B & C (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : (a) A & B *
Description : As per norms for desirable amenity as given to model station, the water coolers should be provided on stations classified as --- (a) A & B (b) A,B & C (c) A,B,C & D* (d) A, B,C, D & E (e) A
Last Answer : (c) A,B,C & D*
Description : As per norms for desirable amenity as given to model station, the parking facility/circulating area should be provided on stations classified as --- (a) A & B (b) A,B & C (c) A,B,C & D* (d) A, B,C, D & E
Description : As per norms for desirable amenity as given to model station, the public address system should be provided on stations classified as --- (a) A & B (b) A,B & C* (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : (b) A,B & C*
Description : As per norms for desirable amenity as given to model station, the book stalls should be provided on stations classified as --- (a) A & B (b) A,B & C* (c) A,B,C & D (d) A, B,C, D & E (e) A
Description : As per norms for desirable amenity as given to model station, the refreshment rooms should be provided on stations classified as --- (a) A & B* (b) A,B & C (c) A,B,C & D (d) A, B,C, D & E (e) A
Last Answer : (a) A & B*
Description : Number of model stations identified for development on Indian Railways is about (a) 55 (b) 110* (c) 265 (d) 320
Last Answer : b) 110*
Description : Height of Low level platform for passengers for BG is --- high (a) 0.455 m* (b) 0.560 m (c) 0.650 m (d) 0.760 m
Last Answer : (a) 0.455 m*
Description : Height of high level platform for passengers for BG is --- high (a) 0.455 m (b) 0.560 m (c) 0.650 m (d) 0.760 m*
Last Answer : (d) 0.760 m*
Description : “B” class station is provided only on (a) Single lines (b) Double line (c) On both single as well as double line* (d) None of them
Last Answer : c) On both single as well as double line*
Description : Size of cubicle of a booking office is kept as (a) 1.20 x 1.50 m (b) 1.50 x 1.20 m (c) 1.50 x 1.80 m (d) 1.80 x 1.50 m*
Last Answer : (d) 1.80 x 1.50 m*
Description : Height of platform of a flag station in cutting above rail level is (a) Same height as Rail level (b) 305 mm above rail level (c) 455 mm above rail level (d) 840mm above rail level*
Last Answer : (d) 840mm above rail level*
Description : Which of the facilities do not exist at halt station? (a) Facilities for stopping the train (b) Facilities for a small waiting (c) Facilities for crossing of train* (d) Facilities for book of passengers
Last Answer : (c) Facilities for crossing of train*
Description : Number of taps on platform as per norms for recommended level of facilities (a) One for every coach (b) One for alternate coach* (c) One every 200 metres distance (d) At the discretion of DRM
Last Answer : (b) One for alternate coach*
Description : Urinals & Latrines for A & B stations as norms for recommended level of facilities for railway station (a) Ndb/500 (b) Ndb/300 (c) Ndb/200* (d) None of the above
Last Answer : (c) Ndb/200*
Description : Number of urinals & latrines to be provided on ‘A’ category stations as per norms on main essential facilities are (a) 15 (b) 10* (c) 8 (d) 6
Last Answer : (b) 10*
Description : Number of taps to be provided on ‘A’ category stations on each platform as per norms of minimum essential facilities are (a) 20 taps (b) 15 taps (c) 12 taps* (d) One taps for each bogie
Last Answer : (c) 12 taps*
Description : Latrines & urinals must be provided on these type of stations as per minimum essential facility criteria (a) A, B, C, D, E & F type station (b) A,B,C,D & E type station* (c) A,B,C & D type station (d) A, B & C type station
Last Answer : (b) A,B,C,D & E type station*
Description : Foot over bridge must be provided on the following type of stations as per minimum essential facility criteria (a) A, B, C, & D class station (b) A,B & C class station* (c) A, & B class station (d) Only A class station
Last Answer : b) A,B & C class station*
Description : For ‘B’ category stations as per minimum essential facility it is necessary to provide (a) High level platform (b) Medium level platform* (c) Rail level platform (d) All the above
Last Answer : (b) Medium level platform*
Description : For ‘A’ category stations it is necessary to provide (a) High level platform* (b) Medium level platform (c) Rail level platform (d) All the above
Last Answer : (a) High level platform*