The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

1 Answer

Answer :

The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm

Related questions

Description : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

Last Answer : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Description : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is (A) 1.2 kW (B) 1 kW (C) 600 W (D) 500 W

Last Answer : The disc of a single phase Induction-type energy meter makes 60 revolutions in 6 minutes. Meter Constant is 1200 rev/kWh. Power consumption in the load is 500 W

Description : A meter whose constant is 600 revolutions/kWh makes 5 revolutions in 20 seconds. Calculate the load in kW. (1) 0.5 kW (2) 1 kW (3) 1.5 kW (4) 2 kW  

Last Answer : 1.5 kW 

Description : An energy meter has a constant of 600 rev/kWh. If the meter makes 10 revolutions in 20 s, what is the load in kW?  (A) 0.75 kW (B) 1.5 kW (C) 3 kW (D) 6 kW 

Last Answer : 1.5 kW 

Description : A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

Last Answer : 2

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : According to the definition of 1 KWh, a 100 watt bulb consumes one unit of electricity in _____. A. 1 Hour B. 5 Hours C. 8 Hours D. 10 Hours

Last Answer : ANSWER: D

Description : According to the definition of 1 KWh, a 100 watt bulb consumes one unit of electricity in _____. A. 1 Hour B. 5 Hours C. 8 Hours D. 10 Hours

Last Answer : ANSWER: D

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

Last Answer : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be 115 V.

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is  (A) 2.43 A (B) 1.65 A (C) 1.22 A (D) 1.0 A

Last Answer : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is 1.0 A

Description : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is (A) sinusoidal current (B) constant dc current (C) continuous rectangular pulses (D) alternating rectangular pulses

Last Answer : In a 230 V, 50 Hz single-phase SCR bridge converter operating at a firing delay angle, α and with large R-L load, the input source current is alternating rectangular pulses

Description : Power (P) in a 3 phase circuit with two watt meters at unity power factor is (W1 & W2 = watt meter readings)

Last Answer : Power (P) in a 3 phase circuit with two watt meters at unity power factor is P = W1 + W2 (W1 & W2 = watt meter readings)

Description : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Description : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 

Last Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent

Description : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for

Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

Description : A single phase wattmeter rated for 500 V; 5A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

Last Answer : Answer :

Description : Induction watt-hour meters are free from (a) phase (b) creeping (c) temperature (d) frequency

Last Answer : b

Description : What is the quantity shown on the watt-hour meter in figure 1-46?

Last Answer : 5.945 megawatt-hours, or 5,945 kilowatt-hours, or 5,945, 000 watt-hours.

Description : What electrical quantity is measured by a watt-hour meter?

Last Answer : Energy.

Description : What type of instrument is the watt-hour meter?

Last Answer : an integrating

Description : According to the definition of 1 KWh, a 100 watt bulb consumes one unit of electricity in-----? A. 2 hours B. 5 hours C. 8 hours D. 10 hours (Answer)

Last Answer : D. 10 hours (Answer)

Description : According to the definition of 1 KWh, a 100 watt bulb consumes one unit of electricity in------? A. 1 hours B. 5 hours C. 10 hours (Answer) D. 15 hours

Last Answer : C. 10 hours (Answer)

Description : The difference between the synchronous speed of an induction machine and its operating speed (slip) may be correctly expressed _____________. A. as a percent of synchronous speed B. as a decimal fraction of synchronous speed C. directly in revolutions per minute D. as all of the above

Last Answer : Answer: A

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : How much do you pay per kilowatt-hour (kwh) for your electricity?

Last Answer : 1. there are three levels of pricing, depending on how much is used 0-700 =0.093 700-1000=0.157 over1000 = 0.175 per KWH in the summer. This varies seasonally 2. Northern California 3.Natural ... therms (seasonal) 0.968 above that 1.213 3. Gasoline for automobile $2.83.9 (yesterday, changes daily)

Description : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by   (a) 90o (b) 0o (c) 45o (d) 60o

Last Answer : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 90o

Description :  In a household single phase induction type wattmeter, the meter can be reversed by: - a) reversing the supply terminals b) reversing the load terminal c) opening the meter connection ... opening the meter and reversing the connection of both the potential coil terminals and current coil terminals

Last Answer :  In a household single phase induction type wattmeter, the meter can be reversed by: - opening the meter connection and reversing either the potential coil terminals or current coil terminals 

Description : kWh meter is the electric meter that measures the amount of electrical _________ in kWh that was consumed in the house.  (A) Energy (B) Current (C) Voltage (D) None of the above

Last Answer : kWh meter is the electric meter that measures the amount of electrical Energy in kWh that was consumed in the house. 

Description : To pump water from a water reservoir 3 m deep and maximum water level at 135 m, a pump is  installed to lift water up to R.L. 175 m at a constant rate of 36,00,000 litres per hour. If the length  of the ... the water horse power of the pump is  (A) 400  (B) 450  (C) 500 (D) 600

Last Answer : (D) 600

Description : CG Co manufactures a single product T. Budgeted production output of product T during June is  200 units. Each unit of product T requires 6 labour hours for completion and CG Co anticipates 20 per  cent idle time. Labour is paid at ... for March is (a) Rs 6,720 (b) 8,400 (c) 10,080 (d) 10,500

Last Answer : (d) 10,500

Description : The magnetizing reactance of a 4 kV/ 400 V, 50 Hz single-phase transformer on low voltage side is 35 Ω. The magnetizing reactance on the high voltage side is (A) 0.35 Ω (B) 3.5 Ω (C) 350 Ω (D) 3500 Ω

Last Answer : 3500

Description : A 10 kVA, 400 V/200 V single phase transformer with 10% impedance draws a steady short-circuit line current of   (a) 250A (b) 50 A (c) 150 A (d) 350 A 

Last Answer : A 10 kVA, 400 V/200 V single phase transformer with 10% impedance draws a steady short-circuit line current of 250A

Description : What will be the frequency of a three-phase, six pole, AC generator operating at 1800 revolutions per minute? A. 60 hertz B. 90 hertz C. 120 hertz D. 180 hertz

Last Answer : Answer: B

Description : A flywheel rotating at 5 revolutions per second is brought to rest by a constant torque in 10 seconds. How many revolutions does the flywheel make while coming to a stop? w) 25 x) 50 y) 75 z) 100

Last Answer : ANSWER: W -- 25

Description : The usual energy consumption in electric arc furnace steel making is __________ KWh/ton of steel. (A) 60 - 100 (B) 400 - 700 (C) 1200 -1500 (D) 2000 - 2300

Last Answer : (B) 400 - 700

Description : A 100-watt light bulb is left on for 10 hours. Electricity is 10 cents per kilowatt-hour. How much did it cost to operate the light bulb?

Last Answer : ANSWER: 10 CENTS

Description : In a 100 TPD Sponge Iron plant, the sponge iron is fed to the Induction melting furnace,  producing molten steel at 88% yield. The Energy consumption details are as follows: Coal Consumption : 130 ... molten  steel (product). 3. Total Energy Consumption of Plant in Tons of Oil Equivalent (TOE )

Last Answer :  a) Specific Energy Consumption of Induction Melting Furnace  Molten Steel Production from the Induction melting furnace per day  = 100 x 88/100 = 88 TPD Total Energy Consumption of the Plant = 82400 kWh ... mark c) Total Energy consumption of Plant in ToE  = 655864000/107  = 65.586 ToE

Description : what is the reading in kwh of the electric meter shown in the exam figure below? -General Knowledge

Last Answer : 0631 is the reading in kwh of the electric meter shown in the exam figure below.

Description : The meter installed in our homes measure electricity in _____. A. KWh B. WKh C. Hkw D. Khw

Last Answer : ANSWER: A

Description : The meter installed in our homes measure electricity in _____. A. KWh B. WKh C. Hkw D. Khw

Last Answer : ANSWER: A

Description : The meter installed in our homes measure electricity in _____. A. KWh B. WKh C. Hkw D. Khw

Last Answer : ANSWER: A

Description : a single phase full wave midpoint thyristor converter uses a 230/200V transformer with centre tap on the secondary side. The P.I.V per thyristor is   (A) 100V (B)141.4V (C)200V (D)282.8V

Last Answer : d

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : Kilowatt-hour (KWH) is the unit of - (1) power (2) resistance (3) resistivity (4) energy

Last Answer : (4) energy Explanation: The kilowatt hour (symbol kWh, kW h or kW h) is a unit of energy equal to 3.6 megajoules. If the energy is being transmitted or used at a constant rate (power) over a period of time, the total energy in kilowatt hours is the power in kilowatts multiplied by the time in hours.