.Oil or water on impression for treatment casts causes:
A. An increase of the quality
B. No alteration
C. A decrease of the quality
D. Bubbles on the cast

1 Answer

Answer :

C. A decrease of the quality

Related questions

Description : A partial denture that seats on the master cast but fails to seat correctly in the mouth is a result of, A. Contraction of the metal framework during casting B. Insufficient expansion of the investment material C. Distortion of impression D. Failure to block out unwanted undercuts

Last Answer : C. Distortion of impression

Description : A cast crown fits on the die but not on the tooth, the discrepancy is about 0.3mm, what would you do: A. Relieve cast from the inside B. Take a new impression and make new crown C. Burnish margins D. Use thick mix of cement

Last Answer : B. Take a new impression and make new crown

Description : When all other removable partial denture considerations remain unchanged; clasps constructed of which material can engage the deepest undercut: A. Chrome cobalt casts B. Nickel chrome casts C. Wrought stainless steel (0,5mm) D. Wrought gold

Last Answer : D. Wrought gold

Description : vDentinogeneses imperfecta develops in: A. Initial stage (number alteration) B. Proliferation stage (forma y tamaño) C. Histodifferentiation stage D. Morphology stage (forma y tamaño)

Last Answer : C. Histodifferentiation stage

Description : Explain when a type conversion will undergo an implicit cast and when you must perform an explicit cast. What are the dangers associated with explicit casts?

Last Answer : Types can be implicitly converted when the conversion can always take place without any potential loss of data. When a potential loss of data is possible, an explicit cast is required. If an explicit cast is improperly performed, a loss of data precision can result, or an exception can be thrown.

Description : The advantage of firing porcelain in vacuum:** A. Reduces size of air-bubbles incorporated thus decreasing porosity B. Removes water before firing, increasing the hardness of porcelain C. Significantly lowers firing temperature

Last Answer : A. Reduces size of air-bubbles incorporated thus decreasing porosity

Description : How long should acrylic self-cure special trays been made prior to taking impression: A. 12 hrs B. Immediately after fabricating it C. After been left in water for an hour D. Wait for an hour before pouring

Last Answer : A. 12 hrs

Description : Elastomers are:** A. Hydrophilic B. Hydrophobic C. Water-loving impression material D. Potassium alginates E. None of the above

Last Answer : B. Hydrophobic

Description : The disadvantage of heating the impression compound in a water bath is: A. It may become brittle B. It may become grainy C. Lower moles with constituents are leached out D. The plasticity of the compound may be altered E. All of the above

Last Answer : D. The plasticity of the compound may be altered

Description : Which impression material should NOT be kept in water within on hour: (in another paper it was: 30  mins before pouring)  A. Polyether  B. Condensation silicone  C. Polyvinyl silicone 

Last Answer : A. Polyether 

Description : Which of the following is true regarding preparation of custom tray for elastomeric impression: a. Adhesive is preferred over perforation. b. Perforation provides adequate retention c. Adhesive is ... before procedure d. Perforations are not made in the area over the prepared tooth .

Last Answer : a. Adhesive is preferred over perforation.

Description : The removable partial denture requires relining what would be the most appropriate action, A. take a new impression by asking the patient to occlude on it B. Provide equal space (maybe it was ... gingival tissues. C. Make sure the framework and retainers are seated in place before taking impression

Last Answer : C. Make sure the framework and retainers are seated in place before taking impression

Description : The polysulfide rubber impression materials are: A. Not sensitive to temperature when curing B. Quite sensitive to temperature when curing C. Less sensitive to temperature than silicone rubber D. The same sensitivity to temperature as silicone rubber E. None of the above

Last Answer : B. Quite sensitive to temperature when curing

Description : Dental impression materials are hydrocolloids of: A. The emulsoid type B. The suspension type C. The sol type D. The gel type E. None of the above

Last Answer : A. The emulsoid type

Description : Fusion temperature of impression compound should occur: A. Below mouth temperature B. Above mouth temperature C. As of the skin temperature D. At the room temperature E. None of the above

Last Answer : B. Above mouth temperature

Description : After making an impression to reline an RPD the dentist notes that the indirect retainers are not resting on the tooth. To avoid this, what process should have undertaken initially: A. Ask ... abutment tooth while setting C. Fabricate new denture D. Add impression material and close the gap

Last Answer : B. Hold the metal base frame against the abutment tooth while setting

Description : Which one of the following is the major disadvantage of stone dies used for crown fabrication, A. They lack accurate reproduction of surface details B. Their overall dimensions are slightly smaller than ... of the stone D. The hazard of aspiration of toxic materials during trimming of the dies.

Last Answer : A. They lack accurate reproduction of surface details

Description : .Which of the following is true regarding preparation of custom tray for elastomeric impression: A. Adhesive is preferred over perforation B. Perforation provides adequate retention C. Adhesive is ... immediately before procedure D. Perforations are not made in the area over the prepared tooth

Last Answer : A. Adhesive is preferred over perforation

Description : A crown casting with a chamfer margin fits the die; but in the mouth the casting is open approximately 0.3mm. A satisfactory fit and accurate physiological close of the gingival area of the crown ... the crown E. Relieving the inside of the occlusal surface of the casting to allow for further

Last Answer : D. Making a new impression and remaking the crown

Description : An impression with elastomer in custom tray has been taken for crown preparation; it will be two days before the impression gets to the laboratory for construction of the crown. Which impression ... A. Polyether B. Thiokol or meraptan rubber C. Condensation silicone D. Vinyl polysiloxane

Last Answer : D. Vinyl polysiloxane

Description : To minimize the load on a free-end saddle partial denture: (distal extension saddle) A. Use teeth with narrow Buccal-Lingual dimension B. Use mucco-compressive impression

Last Answer : B. Use mucco-compressive impression

Description : Jaw relations for edentulous patient have been established. The maxillary cast has been mounted on the articulator without face-bow and you decide to increase the occlusal vertical dimension by 4 mm ... record C. Changes in the condylar guide settings D. Increase in the vertical dimension

Last Answer : B. A new centric relation record

Description : You can increase the retention of a Maryland bridge by: A. Incorporating mesh work in wax pattern B. Perforation techniques in the metal cast

Last Answer : A. Incorporating mesh work in wax pattern

Description : Jaw relation of an edentulous patient has been established. The maxillary cast has been mounted on an articulator without a face bow. You decide to increase the occlusal vertical dimension by 4mm this ... C. A change in the condylar guide settings D. An increase in the rest vertical dimension

Last Answer : B. A new centric relation to be recorded

Description : Which is NOT a correct consequence of surgical removal of portions of these glands? A) adrenal cortex--bronzing of skin, no glucose at stress, dehydration and death B) thymus--decrease ... change in secondary sex characteristics E) adult thyroid--low pulse rate and body temperature and lethargy

Last Answer : B) thymus--decrease in sex drive and changes in secondary sexual characteristics

Description : Pick up the correct statement from the following: (A) Air bubbles in casting produce a dull sound by tapping their surfaces lightly with a hammer (B) Cupola furnace is used for the manufacture of cast iron (C) Red short iron is of no value for welding purpose (D) All the above

Last Answer : Answer: Option D

Description : When dry cast is immersed in water saturated with calcium sulphate:** A. There is contraction B. There is negligible expansion C. There is definite expansion D. There is no change E. None of the above

Last Answer : B. There is negligible expansion

Description : When patient bites in protrusion with complete dentures you notice that the posterior teeth do not meet, what would you do to solve this: A. Increase the compensatory curve B. Decrease the angle of the occlusal plane

Last Answer : A. Increase the compensatory curve

Description : The initial condylar guidance of 25 degrees was wrong and is changed to 45 degrees. What changes will you make to achieve balanced occlusion: A. Decrease incisal guidance B. Reduce cusps height C. Increase compensation curve

Last Answer : C. Increase compensation curve

Description : Why do you itch enamel for composite restorations: A. To increase surface area B. To decrease surface area C. Does not really change the surface area D. Increase the chemical bonding capability E. Decrease the chemical bonding capability

Last Answer : A. To increase surface area

Description : .Which of the following is true:  A. Antibiotics are useful in the treatment of periodontitis   B. Trauma from occlusion causes thickening of the marginal gingivae  C. Periodontitis is the ... can be identified by x-ray  E. Periodontitis is the most common disease in the oral cavity

Last Answer : E. Periodontitis is the most common disease in the oral cavity

Description : The main factor controlling a decision to increase the occlusal height of teeth for extensive oral reconstruction is whether, A. the inter occlusal distance will be physiologically ... the aesthetic appearance of the patient will improve sufficiently to warrant the planned reconstruction

Last Answer : A. the inter occlusal distance will be physiologically acceptable after treatment

Description : The main factor controlling a decision to increase the occlusal height of teeth for extensive oral reconstruction is whether, A. The inter occlusal distance will be physiologically ... . The aesthetic appearance of the patient will improve sufficiently to warrant the planned reconstruction

Last Answer : A. The inter occlusal distance will be physiologically acceptable after treatment

Description : The MOST effective manner to produce a hard surface on a cast is by: A. Employ as much water as possible on mixing B. Employ as little water as possible on mixing C. Adding 2% of borax to the mix D. Adding calcium tetraborate E. None of the above

Last Answer : B. Employ as little water as possible on mixing

Description : In the construction of partial dentures the surveyor is not used to, A. Contour the wax as part of the fabrication of the working cast B. Locate the guide planes C. Determine the location of indirect retainers D. Identify any undesirable undercuts

Last Answer : A. Contour the wax as part of the fabrication of the working cast

Description : Which one of this restorative methods will be LEAST compromised by a core, A. Amalgam B. Composite C. GIC D. Cast gold

Last Answer : D. Cast gold

Description : Why are three tripods marked on a cast being surveyed: A. To orient cast to articulator B. To orient cast to surveyor C. To provide guide planes

Last Answer : B. To orient cast to surveyor

Description : A gingivally extended chrome cobalt cast clasp: A. Can extend 0.5 under the surveyor line B. Can extend 0.25 under the surveyor line C. Will resist deforming forces better compared to cast gold

Last Answer : B. Can extend 0.25 under the surveyor line

Description : How can a periodontal pocket be recognised:** A. X-Ray B. Periodontal probe / Calibrated probe C. Periodontal marker D. Bitewing radiograph E. Sharp explorer F. Study cast

Last Answer : B. Periodontal probe / Calibrated probe

Description : Distortion or change in shape of a cast partial denture clasp during its clinical use probably indicates that the: A. Ductility was too low B. Hardness was too great C. Ultimate tensile strength was too low D. Tension temperature was too high E. Elastic limit was exceeded

Last Answer : E. Elastic limit was exceeded

Description : When surveying: A. Tilt the cast

Last Answer : A. Tilt the cast

Description : Which of the following areas CANNOT be determined by survey analysis of partially edentulous cast? A. Areas to be revealed as blocked out to properly located rigid parts of a frame work B. Areas to be ... planes D. Areas used for retention E. Areas used for support F. Depth of rest seats

Last Answer : F. Depth of rest seats

Description : In planning and construction of a cast metal partial denture the study cast, M07 A. facilitate the construction of custom/special trays B. minimize the need for articulating C. provide only ... best assessed clinically D. can be used as a working cast when duplicating facilities are not available

Last Answer : A. facilitate the construction of custom/special trays

Description : ________________ causes pharmacodynamic drug interaction. a) Gastric motility changes. b) Stimulation of metabolism. c) Alteration of pH of GIT. d)Interactions at receptor site.

Last Answer : d)Interactions at receptor site. 

Description : A patient has developed a sever chest pain and difficulties in breathing while in the dental chair. Your initial response is: a. Administer glycerine trinitrate and monitor patient in upright ... required until confirmed as MI by ECG d. Patient has myocardial infarction as confirmed by ECG

Last Answer : a. Administer glycerine trinitrate and monitor patient in upright position.

Description : Which of the following is the best evidence that a previous periodontal treatment is successful? A. The patient keeps a 3 month recall appointment B. There is no extrinsic stain C. The patient demonstrates good understanding of brushing and flossing techniques D. There is no bleeding on probing

Last Answer : D. There is no bleeding on probing

Description : The loss of the first deciduous molar in 10 years-old children requires: A. Band and loop to maintain space B. Evaluate the case radiographically and then decide whether space maintainer is needed or not C. No treatment

Last Answer : B. Evaluate the case radiographically and then decide whether space maintainer is needed or not

Description : A patient suffers a blow to his maxillary central incisor without resulting in fracture. The pulp may: A. Show immediate necrosis B. Become non-vital but only if treatment is delayed too long C. Become non vital irrespective of treatment D. No changes are seen later if fracture does not occur

Last Answer : C. Become non vital irrespective of treatment

Description : A 10 years-old boy presents with a non-vital, non-mobile tooth. Treatment is: A. Pulpectomy with calcium hydroxide B. Pulpectomy with Zinc oxide eugenol C. Pulpotomy with formocresol D. No treatment is required if tooth is asymptomatic

Last Answer : A. Pulpectomy with calcium hydroxide

Description : A patient has developed a sever chest pain and difficulties in breathing while in the dental chair. Your initial response is: A. Administer glycerine trinitrate and monitor patient in upright ... required until confirmed as MI by ECG D. Patient has myocardial infarction as confirmed by ECG

Last Answer : A. Administer glycerine trinitrate and monitor patient in upright position