Horizontally mounted moving iron instruments use 

 (a) Eddy current damping (b) Electromagnetic damping (c) Fluid friction damping (d) Air friction damping

1 Answer

Answer :

Horizontally mounted moving iron instruments use Air friction damping

Related questions

Last Answer : Moving iron and PMMC instruments can be distinguished from each other by looking at: Scale

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END-AFT END, Top .045 - .049, Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END -AFT END, Top .045 - .049 , Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : In a flail harvester, the cutting operation is performed by a) Horizontally rotating circular blades b) Vertically rotating circular blades c) Knives mounted on a horizontal shaft d) Knives mounted on a vertical shaft Ans. c

Last Answer : ans c

Description : In which plane will the half-wave antenna be operating if it is mounted horizontally?

Last Answer : Vertical plane.

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : In an ac tachometer, the two stator field coils are mounted

Last Answer : In an ac tachometer, the two stator field coils are mounted in space quadrate

Description : Which of the following instruments have least torque/weight ratio: a) Dynamometer type b) PMMC c) Attraction type moving iron d) Repulsion type moving iron

Last Answer : Ans: A

Description : Consider the following statements with regard to Moving Iron (MI) instruments :  1. These instruments possess high operating torque.  2. These instruments can be used in ac and dc circuits.  3. Power consumption in these instruments ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements with regard to Moving Iron (MI) instruments :  1. These instruments possess high operating torque.  2. These instruments can be used in ac and dc circuits.  3. Power consumption in these ... 1 and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Description : In moving iron instruments, eddy current damping cannot be used as  (a) They have a strong operating magnetic, field (b) They are not normally used in vertical position (c) They ... of a permanent magnet required for eddy current damping would distort the existing weak operating magnetic field

Last Answer : In moving iron instruments, eddy current damping cannot be used as The introduction of a permanent magnet required for eddy current damping would distort the existing weak operating magnetic field

Description : Moving iron instruments can be used for measuring (1) Direct currents and voltages (2) Radio frequency currents (3) A.C currents and voltages (4) Both (a) and (c)

Last Answer : moving iron instruments areused to measure A.C curents &  voltages

Description : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be  (1) unaffected (2) decreased (3) increased (4) either decreased or increased depending on the direction of the DC field

Last Answer : An unshielded moving iron voltmeter is used to measure the voltage in an AC circuit. The stray DC magnetic field having a component along the axis will be either decreased or increased depending on the direction of the DC field

Description : Eddy current damping cannot be used for moving iron instrument because

Last Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Last Answer : In a moving iron meter, the deflecting torque is proportional to Square of the current through the coil.

Last Answer : A moving iron ammeter may be compensated for frequency errors by shunt capacitance.

Last Answer : The moving iron voltmeters are likely: To indicate lower value of ac than on dc.

Description : A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under a standard conditions. The maximum possible percentage error in the reading is:

Last Answer : A 150 V moving iron voltmeter of accuracy class 1.0 reads 75 V when used in a circuit under a standard conditions. The maximum possible percentage error in the reading is:  2.0.

Last Answer : A moving iron instrument can be used for both D.C. and A.C.

Description : What type of polarization should be used if an antenna is mounted on a moving vehicle at frequencies below 50 megahertz?

Last Answer : Vertical polarization.

Description : 10. Imagine that you are sitting in a chamber with your back to one wall. An electron beam, moving horizontally from back wall towards the front wall, is deflected by a strong magnetic field to your right side. What is the direction of magnetic field? -Science

Last Answer : The direction of the magnetic field can be determined using the Fleming’s Left hand rule. The direction of the magnetic field will be perpendicular to the direction of current and the direction ... it can be concluded that the direction of the magnetic field inside the chamber is downward.

Description : The electric field applied in vertical directional to the cathode rays moving horizontally deflect them in __________

Last Answer : The electric field applied in vertical directional to the cathode rays moving horizontally deflect them in __________ ... a) and (b) D. None of these

Description : Water jet coming out of a stationary horizontal tube at speed v strikes horizontally a massive wall moving in opposite with same speed. Water come to

Last Answer : Water jet coming out of a stationary horizontal tube at speed v strikes horizontally a massive wall ... energy of water jet striking the wall is zero

Description : Can an object in free fall can be considered to be moving horizontally?

Last Answer : What is the answer ?

Description : When an electron is moving horizontally between oppositely charged plates, it will move in the A. straight line B. fall directly downwards C. move towards positive plates D. curved path

Last Answer : curved path

Description : An ELECTRON moving horizontally along the +x axis enters a region of space with a horizontal uniform magnetic field pointing in the +y direction. The electron will be deflected: w) -y direction x) +y direction y) -z direction z) +z direction

Last Answer : ANSWER: Y -- -Z DIRECTION

Last Answer : PMMC type instruments normally use Eddy current damping.

Description : The use of _____ instruments is merely confined within laboratories as standardising instruments.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Description : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Last Answer : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Description :  Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments

Last Answer : Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments 

Description : The type of instruments used mainly for standardizing instruments in laboratories is (a) Indicating instrument (b) Integrating instrument (c) Absolute instrument (d) Recording instrument  

Last Answer : Ans:Option C

Description : Eddy current damping is normally used in the instruments of (a) Induction type (b) Moving iron type (c) Permanent magnet moving coil type (d) Nothing can be said 

Last Answer : Permanent  magnetic  moving  coil  instrument.

Description : Electrostatic type instruments are primarily used as 

Last Answer : Voltmeter

Description : The force required to move the pointer in an indicating instruments is

Last Answer : The force required to move the pointer in an indicating instruments is deflecting force

Last Answer : Thermocouple instruments are also known as Rectifier instruments.

Last Answer :  Electrostatic instruments are normally used for High voltage measurements.

Description : Which of the following instruments can be used to measure AC current only? (a) Permanent Magnet Type ammeter(b) Induction type ammeter (c) Moving iron voltmeter(d) Moving iron ammeter

Last Answer : (b) Induction type ammeter

Last Answer : Jewels are used in instruments for the purpose of Bearing.

Last Answer : The thermocouple instruments do not have High degree of measuring accuracy.

Last Answer : In the case of PMMC rectifier type instruments, the deflecting torque is proportional to Average value of AC current.

Last Answer : The electrostatic instruments can be used without serious loss of accuracy upto 100kHz frequency.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Last Answer : Air friction damping is used in the instruments which is: Moving iron

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : Operating torques in analogue instruments are deflecting, control and damping.

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Last Answer : The switch board instruments should be mounted in vertical position.

Last Answer : In the majority of instruments, damping is provided by eddy currents.

Last Answer : According to application, instruments are classified as switch board, portable.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.