Eddy current damping is normally used in the instruments of (a) Induction type (b) Moving iron type (c) Permanent magnet moving coil type (d) Nothing can be said 

1 Answer

Answer :

Permanent  magnetic  moving  coil  instrument.

Related questions

Description : In moving iron instruments, eddy current damping cannot be used as  (a) They have a strong operating magnetic, field (b) They are not normally used in vertical position (c) They ... of a permanent magnet required for eddy current damping would distort the existing weak operating magnetic field

Last Answer : In moving iron instruments, eddy current damping cannot be used as The introduction of a permanent magnet required for eddy current damping would distort the existing weak operating magnetic field

Description : Eddy current damping cannot be used for moving iron instrument because

Last Answer : Eddy current damping cannot be used for moving iron instrument because the presence of a permanent magnet required for such purpose would affect the deflection and hence the reading of the instrument

Last Answer : The disc of an instrument using eddy current damping should be of conducting and non-magnetic material.

Last Answer : Air friction damping is used in the instruments which is: Moving iron

Last Answer : In the majority of instruments, damping is provided by eddy currents.

Description : Eddy current damping is an example of _____ A Coulomb damping B Hysteresis damping C Viscous damping D Dry friction damping

Last Answer : C Viscous damping

Description : When parts of a vibrating system slide on a dry surface, the damping is A. Viscous. B. Coulomb C. Structural D. Eddy current

Last Answer : B. Coulomb

Description : Eddy current damping is an example of _____A. Coulomb damping B. Hysteresis damping C. Viscous damping D. Dry friction damping

Last Answer : C. Viscous damping

Description : Eddy current damping is an example of _____ A) Coulomb damping B) Hysteresis damping C) Viscous damping D) Dry friction damping

Last Answer : C) Viscous damping

Description : Eddy current damping is an example of _____ a. Coulomb damping b. Hysteresis damping c. Viscous damping d. Dry friction damping

Last Answer : c. Viscous damping

Description : When a synchronous motor is running at synchronous speed, the damper winding produces (A) damping torque. (B) eddy current torque. (C) torque aiding the developed torque. (D) no torque.

Last Answer : (D) no torque.

Last Answer : PMMC type instruments normally use Eddy current damping.

Last Answer :  Electrostatic instruments are normally used for High voltage measurements.

Last Answer : No eddy current and hysteresis losses occur in Electrostatic instruments.

Description : Which of the following instruments can be used to measure AC current only? (a) Permanent Magnet Type ammeter(b) Induction type ammeter (c) Moving iron voltmeter(d) Moving iron ammeter

Last Answer : (b) Induction type ammeter

Description : The best and efficient damping in Analog instruments is : - a) Air Friction damping b) Fluid Friction damping c) Eddy Current damping d) None of the above

Last Answer : The best and efficient damping in Analog instruments is : - Eddy Current damping

Description : Control systems are generally designed with damping  a) less than one  b) greater than one c) equal to one d) with any value depending upon system requirement

Last Answer : Control systems are generally designed with damping  less than one 

Description : A control system having unit damping factor will give  (1) Oscillatory response (2) Undamped response (3) Critically damped response (4) No response

Last Answer : 1

Description : Ideally, the damping torque should be  (1) Proportional to velocity of the moving system and operating current.  (2) Proportional to the velocity of the moving system but independent of operating ... operating current.  (4) Independent of the velocity of the moving system and operating current.

Last Answer : Ideally, the damping torque should be Proportional to the velocity of the moving system but independent of operating current. 

Description : In a PMMC instrument, the damping provided is :  (A) air damping (C) eddy current damping (B) fluid damping (D) magnetic damping using a magnet

Last Answer : In a PMMC instrument, the damping provided is : eddy current damping 

Last Answer : For the indicating instrument the preferred damping condition is  a damping coefficient of 0.8 to 1.

Last Answer : In moving coil meters, damping is provided by eddy current disk.

Last Answer : The damping torque must operate only when the moving system of the indicating instrument is: Actually moving

Last Answer : Damping of the Ballistic galvanometer is made small to get first deflection large.

Description : On oscilloscope screen for dynamic measurement, lissajous diagram is normally used to determine the __________ of the input signal. (A) Frequency (B) Amplitude (C) Damping (D) None of these

Last Answer : (A) Frequency

Description : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Last Answer : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Description :  Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments

Last Answer : Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments 

Description : The type of instruments used mainly for standardizing instruments in laboratories is (a) Indicating instrument (b) Integrating instrument (c) Absolute instrument (d) Recording instrument  

Last Answer : Ans:Option C

Description : Electrostatic type instruments are primarily used as 

Last Answer : Voltmeter

Description : The force required to move the pointer in an indicating instruments is

Last Answer : The force required to move the pointer in an indicating instruments is deflecting force

Description : Horizontally mounted moving iron instruments use   (a) Eddy current damping (b) Electromagnetic damping (c) Fluid friction damping (d) Air friction damping

Last Answer : Horizontally mounted moving iron instruments use Air friction damping

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Last Answer : Thermocouple instruments are also known as Rectifier instruments.

Last Answer : Jewels are used in instruments for the purpose of Bearing.

Last Answer : The thermocouple instruments do not have High degree of measuring accuracy.

Last Answer : In the case of PMMC rectifier type instruments, the deflecting torque is proportional to Average value of AC current.

Last Answer : The electrostatic instruments can be used without serious loss of accuracy upto 100kHz frequency.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Description : The use of _____ instruments is merely confined within laboratories as standardising instruments.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Last Answer : Moving iron and PMMC instruments can be distinguished from each other by looking at: Scale

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : Operating torques in analogue instruments are deflecting, control and damping.

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Last Answer : The switch board instruments should be mounted in vertical position.

Last Answer : According to application, instruments are classified as switch board, portable.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Description : What do you mean by secondary instruments?

Last Answer : The instruments which will give the direct readings are called secondary instruments

Description : Resistance grounding is normally used for :  (A) high voltage long over head transmission lines  (B) low voltage short over head transmission lines  (C) extra high voltage long over head transmission lines  (D) all the above

Last Answer : Resistance grounding is normally used for : low voltage short over head transmission lines

Last Answer : The error of an instrument is normally given as a percentage of full-scale value.