Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

1 Answer

Answer :

Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Related questions

Description : Accurate measurement of very low resistances is possible with (A) Megger (B) Wheatstone Bridge (C) Kelvin’s Double Bridge (D) Wagner’s Earthing Device

Last Answer : Accurate measurement of very low resistances is possible with Kelvin’s Double Bridge

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : If an inductance is connected in one arm of bridge and resistances in the remaining three arms the bridge cannot be balanced.

Last Answer : Resistances can be measured with the help of ohmmeters and resistance bridges.

Last Answer : For measurement of inductance having high value, we should use Hay's bridge.

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : Electrostatic type instruments are mainly used for measurement of: a) Heavy currents b) Low currents c) Low voltages d) High voltages

Last Answer : Ans: D

Description :  Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments

Last Answer : Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments 

Description : The type of instruments used mainly for standardizing instruments in laboratories is (a) Indicating instrument (b) Integrating instrument (c) Absolute instrument (d) Recording instrument  

Last Answer : Ans:Option C

Description : Eddy current damping is normally used in the instruments of (a) Induction type (b) Moving iron type (c) Permanent magnet moving coil type (d) Nothing can be said 

Last Answer : Permanent  magnetic  moving  coil  instrument.

Description : Electrostatic type instruments are primarily used as 

Last Answer : Voltmeter

Description : The force required to move the pointer in an indicating instruments is

Last Answer : The force required to move the pointer in an indicating instruments is deflecting force

Description : Horizontally mounted moving iron instruments use   (a) Eddy current damping (b) Electromagnetic damping (c) Fluid friction damping (d) Air friction damping

Last Answer : Horizontally mounted moving iron instruments use Air friction damping

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Last Answer : Thermocouple instruments are also known as Rectifier instruments.

Last Answer : PMMC type instruments normally use Eddy current damping.

Last Answer :  Electrostatic instruments are normally used for High voltage measurements.

Description : Which of the following instruments can be used to measure AC current only? (a) Permanent Magnet Type ammeter(b) Induction type ammeter (c) Moving iron voltmeter(d) Moving iron ammeter

Last Answer : (b) Induction type ammeter

Last Answer : Jewels are used in instruments for the purpose of Bearing.

Last Answer : The thermocouple instruments do not have High degree of measuring accuracy.

Last Answer : In the case of PMMC rectifier type instruments, the deflecting torque is proportional to Average value of AC current.

Last Answer : The electrostatic instruments can be used without serious loss of accuracy upto 100kHz frequency.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Description : The use of _____ instruments is merely confined within laboratories as standardising instruments.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Last Answer : Air friction damping is used in the instruments which is: Moving iron

Last Answer : Moving iron and PMMC instruments can be distinguished from each other by looking at: Scale

Last Answer : Operating torques in analogue instruments are deflecting, control and damping.

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Last Answer : The switch board instruments should be mounted in vertical position.

Last Answer : In the majority of instruments, damping is provided by eddy currents.

Last Answer : According to application, instruments are classified as switch board, portable.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Description : What do you mean by secondary instruments?

Last Answer : The instruments which will give the direct readings are called secondary instruments

Description : Instruments of Measure The device used ' for the measurement of current, voltage and resistance is: A. AVO meter B. Galvanometer C. Ammeter D. Ohm meter

Last Answer : ANSWER: A

Description : In order to increase its range of measurement, a resistance would be placed in series with which of the following instruments? A. DC voltmeter B. DC ammeter C. frequency meter D. power factor meter

Last Answer : Answer: A

Description : Internal validity refers to which of the following? a. The ability to infer that a casual relationship exists between 2 variables b. The extent to which study results can be generalized to and ... the study d. The ability to generalize the study results to individuals not included in the study

Last Answer : b. The extent to which study results can be generalized to and across populations of persons, settings, and times

Description : List any four instruments used for linear measurement 

Last Answer : 1) Chain 2) Tape 3) Arrows 4) Pegs 5) Ranging rod 

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : The function of measurement system is/are _____.

Last Answer : The function of measurement system are indicating, recording and controlling function.

Description : The measurement range of an ammeter can be increased by using a:

Last Answer : The measurement range of an ammeter can be increased by using a: low resistance in shunt

Description : Clamp on ammeter is used for measurement of:

Last Answer : Clamp on ammeter is used for measurement of: large alternating currents

Description : Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is   (A)sinusoidal (B) square (C) rectangular (D) triangular

Last Answer : Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is sinusoidal 

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : Integrating principle in the digital measurement is the conversion of   (a) Voltage to time (b) Voltage to frequency (c) Voltage to current (d) Current to voltage

Last Answer : Integrating principle in the digital measurement is the conversion of Voltage to frequency

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is  (1) d,a,c,b (2) d, c, a, b (3) a, c, b, d (4) a, b, c, d

Last Answer : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is d,a,c,b

Description : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Last Answer : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Last Answer : A measure of the reproducibility of measurement is known as Precision.