In power-operated sprayer, the pump works at a pressure of: A. 2-5 Kg/cm2 B. 3-8.5 Kg/cm2 C. 4-12 Kg/cm2. D. 5-15 Kg/cm2

1 Answer

Answer :

3-8.5 Kg/cm2

Related questions

Description : Foot or pedal operated sprayer develops pressure a. 14 to 18kg/cm2 b. 15 to 21 kg/cm2 d. None of above

Last Answer : Ans-   c. 17 to 21 kg/cm2

Description : Operating pressure of power operated sprayer E. 1-7 kg/cm2 F. 10-20 kg/cm2+ G. 20-55 kg/cm2 H. >55 kg/cm2

Last Answer : G. 20-55 kg/cm2

Description : Hand operated sprayer are operated at a pressure (kg/cm2) a) 1-7 b) 7-10 c)10-20 d) 20-55

Last Answer : a) 1-7

Description : Operating pressure of the hand operated sprayer is E. 20-55 kg/cm2 F. 1-7 kg/cm2 G. 10-20 kg/cm2 H. >55 kg/cm2

Last Answer : F. 1-7 kg/cm2

Description : Rocker sprayer develops pressure b. 15 to 20kg/cm2 c. 15 to 25 kg/cm2 d. None of above

Last Answer : Ans-   a. 14 to 18kg/cm2

Description : The pump is used in power-operated sprayer is: A. Plunger type B. Diaphragm type C. Gear type D. Piston type

Last Answer : Gear type

Description : Motorized Knapsack sprayer develops pressure below a. 3.5 kg/cm2b. 2.5 kg/cm2 d. None of above

Last Answer : Ans-   c. 1.5 kg/cm2  

Description : Battery operated sprayer consists of 10 lit capacity tank and rechargeable battery. b. 10 Volt c. 12 Volt. d. None of above Ans- a. 6 Volt

Last Answer : Ans-    a. 6 Volt

Description : Hand compression sprayer , the pumping is required to maintain the normal pressure of a. 1-3.5kg/cm2.. b. 1.5-3.5kg/cm2. d. None of above

Last Answer : Ans- c. 2-3.5kg/cm2.

Description : Power sprayers are operated at a pressure of — kg/cm2 a. 5 to 10 b. 10 to 20 c. 20 to 55 d. more than 55

Last Answer : c. 20 to 55

Description : Power sprayers are operated at a pressure of — kg/cm2 a. 5 to 10 b. 10 to 20 c. 20 to 55 d. more than 55

Last Answer : c. 20 to 55

Description : Knapsack hand compression sprayer develops pressure between a) 2 to 3.5 kg/cm b) 3 to 12 kg/cm c) 12 to 35 kg/cm d) None of the above

Last Answer : 3 to 12 kg/cm

Description : The power developed in prime mover of power operated sprayer is a) 1 to 5 HP b) 5 to 10 HP c) 10 to 20 HP d) None of the above

Last Answer : 1 to 5 HP

Description : Sprayer are versatile and simple power operated machines. a) Foot pedal sprayer b) Motorized knapsack sprayer c) Hand optimizer d) All of the above

Last Answer : Motorized knapsack sprayer

Description : In battery operated sprayer fit Volta rechargeable battery. a. 3 c. 4 b. 5. d. 6

Last Answer : 6

Description : Hand operated sprayers are operated at pressure— kg/cm2 a. 7 to 10 b. 10 to 20 c. 1 to 7 d. 20 to 25

Last Answer : c. 1 to 7

Description : Hand operated sprayers are operated at pressure— kg/cm2 a. 7 to 10 b. 10 to 20 c. 1 to 7 d. 20 to 25

Last Answer : c. 1 to 7

Description : Rocker sprayer and Foot or pedal operated sprayer a. have small built tank b. have big built tank d. None of above

Last Answer : Ans- c. does not have in built tank and separate spray tank is necessary.    

Description : Foot or pedal sprayer developed Kg/cm^3 Pressure. a. 17-21. c. 18-25 b. 17- 28. d. 20-25

Last Answer :  17-21.

Description : Knapsack hand compression sprayer develops pressure b. 1.5-3.5kg/cm2. c. 2-3.5kg/cm2. d. None of above

Last Answer : Ans- a. 3 to 12kg/cm2.

Description : Bucket type sprayer consist of: i) Single and double acting pump c) Plunger type pump j) Centrifugal pump d) All are correct

Last Answer : Single and double acting pump

Description : Bucket type sprayer consist of: A. Single and double acting pump B. Centrifugal pump C. Plunger type pump D. All are correct

Last Answer : Single and double acting pump

Description : A 8 metre long simply supported rectangular beam which carries a distributed load 45 kg/m. experiences a maximum fibre stress 160 kg/cm2 . If the moment of inertia of the beam is 640 cm4 , the overall depth of the beam is (A) 10 cm (B) 12 cm (C) 15 cm (D) 18 cm

Last Answer : (A) 10 cm

Description : Saturated steam at a pressure of 25 kg/cm2is throttled to attain 5 kg/cm2. Then the outcoming steam will be (A) Wet (B) Saturated (C) Superheated (D) None of these

Last Answer : C) Superheated

Description : Which of the following is the largest quantum of pressure? (A) 1 kg/cm2 (B) 1 bar (C) 1 atmosphere (D) 1 kilo Pascal

Last Answer : (C) 1 atmosphere

Description : The injection pressure of ic engine used on tractors is in range of kg/cm2 1. 0-6 2. 60-120 3. 120-200 4. 200-300

Last Answer : ans 3

Description : The unit of pressure in S.I. units is  (a) kg/cm2  (b) mm of water column  (c) pascal  (d) dynes per square cm  (e) bars

Last Answer : Answer : c

Description : If the average compressive strength is 4000 kg/cm2 and standard deviation is 500, the co-efficient of variation is (A) 10 % (B) 12.5 % (C) 15 % (D) 18.5%

Last Answer : Answer: Option B

Description : A Power sprayer essentially consists of: a) Tank a) Agitator b) Pressure Gauge c) All of the above

Last Answer : All of the above

Description : The difference in the reservoir level and the lowest point of the water mains is 180 m. The  expected pressure due to water hammer is 7.5 kg/cm2  in a pressure conduit of diameter 1 m.  Assuming the efficiency of the ... , is  (A) 10 mm  (B) 15 mm  (C) 20 mm  (D) 25 mm 

Last Answer : (C) 20 mm

Description : Pressure maintained in the high pressure primary tower of a three stage crude oil distillation system is about __________ kg/cm2 . (A) 1.5 (B) 3 (C) 6 (D) 12

Last Answer : (B) 3

Description : The preliminary test is repeated if the difference of compressive strength of three test specimens, exceeds (A) 5 kg/cm2 (B) 8 kg/cm2 (C) 10 kg/cm2 (D) 15 kg/cm2

Last Answer : Answer: Option D

Description : The critical pressure at which the latent heat of vaporisation of steam becomes zero is __________ Kg/cm2. (A) 273.15 (B) 225.65 (C) 100.03 (D) 373.15

Last Answer : (B) 225.65

Description : In a combined footing if shear stress does not exceed 5 kg/cm2 , the nominal stirrups provided are (A) 6 legged (B) 8 legged (C) 10 legged (D) 12 legged

Last Answer : Answer: Option B

Description : In a combined footing if shear stress exceeds 5 kg/cm2 , the nominal stirrups provided are: (A) 6 legged (B) 8 legged (C) 10 legged (D) 12 legged

Last Answer : Answer: Option D

Description : In a combined footing, in the zones where the shear stresses are less than 5 kg/cm2 , stirrups to be provided are generally (a) 2 – legged (b) 4-legged (c) 8 – legged (d) 12 legged

Last Answer : (b) 4-legged

Description : Tank capacity of compression sprayer is: A. 10 litres B. 12 litres C. 14 litres D. 20 litres

Last Answer : 14 litres

Description : Which of the following could be the unit of rotational inertia of a body in CGS system? a.cm4 b.gm-cm2 c.107 dynes d.kg-cm2 e.gm-cm4

Last Answer : b. gm-cm2

Description : Inflation pressure in the rear wheels of the tractor varies between a) 0.5 to 1.2 kg/cm2 b) 8 to 1.2 kg/cm2 c) 2 to 1.5 kg/cm2 d) 1.5 to 20 kg/cm2

Last Answer : b) 8 to 1.2 kg/cm2

Description : A tank capacity of knapsack sprayer is about: a. 5-10 litres c) 9-22.5 litres b. 8-10 litres d) 10-25.5 litres

Last Answer : 9-22.5 litres

Description : A tank capacity of knapsack sprayer is about: A. 5-10 litres B. 8-10 litres C. 9-22.5 litres D. 10-25.5 litres

Last Answer : 10-25.5 litres

Description : In a sprayer overlapping can be increased by increasing a) Nozzle diameter b) Pressure c) Discharge d) Height of nozzle Ans. d

Last Answer : ans d

Description : Critical pressure of water is (A) 1 kg / cm2 (B) 100 kg / cm2 (C) 155 kg / cm2 (D) 213.8 kg / cm2 .

Last Answer : Ans: D

Description : power spray are operated at a pressure. a. 5-10 kg/m2 b.10-20 kg/m2 c.20-55 kg/m2 d.>55 kg/m2

Last Answer : c.20-55 kg/m2

Description : Steel Tank in the power sprayer is used to avoid a) Moisturisation b) Corrosion c) Leakages d) Stability

Last Answer : Corrosion

Description : sprayer do not require a separate tank a) Hand compression sprayer b) Knapsack hand compression sprayer c) Rocker sprayer d) Power sprayer

Last Answer : Suppose in a squid game, players wanted to escape the game. If they need to travel 100 km North and 125 km East. What must be their resultant vector?  160.07 m 161.02 m 160.08 km none of the above 161 km

Description : For M 150 mix concrete, according to I.S. specifications, local bond stress, is (A) 5 kg/cm2 (B) 10 kg/cm2 (C) 15 kg/cm2 (D) 20 kg/cm

Last Answer : Answer: Option B

Description : According to I.S. : 456 specifications, the safe diagonal tensile stress for M 150 grade concrete, is (A) 5 kg/cm2 (B) 10 kg/cm2 (C) 15 kg/cm2 (D) 20 kg/cm

Last Answer : Answer: Option A

Description : The stresses developed in concrete and steel in reinforced concrete beam 25 cm width and 70 cm effective depth, are 62.5 kg/cm2 and 250 kg/cm2 respectively. If m = 15, the depth of its neutral axis is (A) 20 cm (B) 25 cm (C) 30 cm (D) 35 cm

Last Answer : Answer: Option C

Description : The bearing capacity of granite is generally (A) 5 to 10 kg/cm2 (B) 15 to 20 kg/cm2 (C) 30 to 35 kg/cm2 (D) 40 to 45 kg/cm2

Last Answer : Answer: Option C