A DC shunt motor has rated rpm of 480. Certain industrial application requires this motor to run at 540 rpm for some time. Which speed control will be desirable? A) Ward Leonard control B) Armature current control C) Field resistance control D) It is not possible to run the motor at more than the rated rpm 

1 Answer

Answer :

A DC shunt motor has rated rpm of 480. Certain industrial application requires this motor to run at 540 rpm for some time. Which speed control will be desirable? A) Ward Leonard control B) Armature current control C) Field resistance control D) It is not possible to run the motor at more than the rated rpm 

Related questions

Description : A 50 kW dc shunt is loaded to draw rated armature current at any given speed. When driven  (i) at half the rated speed by armature voltage control and (ii) at 1.5 times the rated speed by field control, the respective output powers ... kW in (i) and 75 kW in (ii) (D) 50 kW in (i) and 50 kW in (ii)

Last Answer : A 50 kW dc shunt is loaded to draw rated armature current at any given speed. When driven  (i) at half the rated speed by armature voltage control and (ii) at 1.5 times the rated speed by field control, the respective output ... kW in (i) and 75 kW in (ii) (D) 50 kW in (i) and 50 kW in (ii)

Description : State any four applications of DC shunt motor.

Last Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Description : A dc shunt generator has a speed of 800 rpm when delivering 20 A to the load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of ... . (B) more than 800 rpm. (C) less than 800 rpm. (D) both higher or lower than 800 rpm.

Last Answer : (C) less than 800 rpm.

Description : A 4 pole lap wound dc shunt motor rotates at the speed of 1500 rpm, has a flux of 0.4 mWb and the total number of conductors are 1000. What is the value of emf? (A) 100 Volts. (B) 0.1 Volts. (C) 1 Volts. (D) 10 Volts.

Last Answer : Ans: D Given N = 1500 rpm, Φ = 0.4 mWb, Z = 1000, P = 4, & A= 4 Therefore, Eb = NΦPZ / 60 A = 1500 x 0.4 x 4 x 1000 x 10^-3 / 60 x 4 = 60/6 = 10 volts

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : An unsaturated dc shunt motor runs at its rated speed when rated voltage is applied to it. If the supply voltage to the motor is reduced by 25%, the speed of the motor  (a) Increases by 25% (b) Remains the same (c) Decreases by 25% (d) Decrease only slightly by an amount less than 25% 

Last Answer : An unsaturated dc shunt motor runs at its rated speed when rated voltage is applied to it. If the supply voltage to the motor is reduced by 25%, the speed of the motor Remains the same

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : State the function of overload coil and No volt coil in dc motor starter.

Last Answer : Function of Overload Coil: When DC motor is overloaded, the overload coil carries the overload current and produces strong magnetic field to attract a plunger, which short the terminals of ... dc motor is prevented from restarting automatically on recovery of supply without starter and protected.

Description : When 220V dc shunt alternator generating the voltage at rated value. If direction of rotation is reversed, then alternator will a) Build up its voltage with same polarity b) Build up its voltage with opposite polarity c) No build up of voltage d) None

Last Answer : Ans: No build up of voltage

Description : The no load speed of a d.c. shunt motor is 1140 rpm. At full load, the armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in rpm will be: (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : The no load speed of a d.c. shunt motor is 1140 rpm. At full load, the armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in rpm will be: 1080

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : The speed of a d.c. shunt motor at no-load is (A) 5 to 10% (B) 15 to 20% (C) 25 to 30% (D) 35 to 40% higher than its speed at rated load.

Last Answer : (A) 5 to 10%

Last Answer : Copper losses,iron losses,variable losses , constant losees

Description : Explain concept of back emf in DC machine. State how it governs armature current. 

Last Answer : Back emf: When the armature of DC machine rotates under the influence of driving torque, the armature conductors move in the magnetic field and cut it and hence emf is induced in them. The ... flow of armature current i.e. it automatically changes the armature current to meet load requirements.

Description : State the function of commutator in DC generator and name the material used for commutator.

Last Answer : Function of Commutator: Commutator converts AC induced in armature winding into DC for external load. Material: i) Commutator segments are made up of Copper. ii) Commutator segments are insulated from each other by Mica.

Description : In a DC machine, which of the following statements is true ?  (A) Compensating winding is used for neutralizing armature reaction while interpole winding is used for producing ... Compensation winding is used for improving commutation while interpole winding is used for producing residual flux

Last Answer : In a DC machine, which of the following statements is true ?  (A) Compensating winding is used for neutralizing armature reaction while interpole winding is used for producing ... Compensation winding is used for improving commutation while interpole winding is used for producing residual flux

Description : What are the slot wedges in a DC machine made of?   (a) Mild steel (b) Silicon steel (c) Fibre (d) Cast iron

Last Answer : What are the slot wedges in a DC machine made of?   (a) Mild steel (b) Silicon steel (c) Fibre (d) Cast iron

Description : For continuously running rolling mills with intermittent loading, the most suitable DC drive is   (a) DC series motor (b) DC shunt motor (c) DC differentially compound motor (d) DC cumulatively compound motor 

Last Answer : For continuously running rolling mills with intermittent loading, the most suitable DC drive is DC cumulatively compound motor 

Description : Fractional pitch windings are used in DC machines to (A) Reduce copper losses (B) Improve cooling (C) Increase the generated emf (D) Reduce sparking

Last Answer : Fractional pitch windings are used in DC machines to Reduce sparking

Description : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :

Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Description : A cumulative dc compound motor runs at 1500 rpm. on full load. If its series field is short-circuited, its speed  (1) becomes zero (2) remains unchanged (3) increases (4) decreases

Last Answer : Increases. As it's cumulative compound motor, both series and shunt field both assist each other. If series field is short circuited, the overall field strength will decrease and atop of that ... speed is inversely proportional to field strength.  So, the speed will increase overall.

Description : State the principle of operation of d.c. motor.

Last Answer : When a current carrying conductor is placed in a magnetic field, the conductor experiences the force. The magnitude of force is given by F = BIL newton  where F – Force   B – maximum flux density   I – Current   L – Length of conductor

Description : When using a megohmmeter to determine which shunt field coil is grounded in a DC machine, you must ____________. A. insulate the field frame from the ship's hull B. disconnect each shunt ... C. use a motor driven high capacity megohmmeter D. remove all main line lead connections before testing

Last Answer : Answer: B

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : If a DC motor runs hot, the cause may be _____________. A. high mica condition B. low ambient temperature C. clogged ventilation ducts D. an open in the shunt field

Last Answer : Answer: C

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : Why Speed Control of Induction Motor is difficult compared to DC shunt motor?

Last Answer : Answer: Speed Control of DC shunt motor can be possible by providing resistance in the armature and field circuits and varying the resistors speed changes can be carried out over a wide range. ... employed. Care should be taken that in the process efficiency and power factor should be maintained.

Description : Give two basic speed control scheme of DC shunt motor?

Last Answer : Answer: 1. By using flux control method: in this method a rheostat is connected across the field wdg to control the field current. So by changing the current the flux produced by the field wdg can ... ) can be varied, and since speed is directly proportional to Eb-IaRa the speed can be controlled.

Description : Regenerative braking (A) Can be used for stopping a motor. (B) Cannot be easily applied to DC series motors. (C) Can be easily applied to DC shunt motors (D) Cannot be used when motor load has overhauling characteristics.

Last Answer : Ans: B Because reversal of Ia would also mean reversal of field and hence of Eb

Description : As compared to shunt and compound DC motors, the series DC motor will have the highest torque because of its comparatively ____________ at the start. (A) Lower armature resistance. (B) Stronger series field. (C) Fewer series turns. (D) Larger armature current.

Last Answer : (D) Larger armature current.

Description : The torque, in a _____________is proportional to the square of the armature current (A) DC shunt motor (B) stepper motor (C) 2-phase servomotor (D) DC series motor

Last Answer : (D) DC series motor

Description : The speed-torque characteristics of a DC series motor are approximately similar to those of the _________motor. (A) universal (B) synchronous (C) DC shunt (D) two-phase

Last Answer : Ans: A Universal motor has same characteristics as DC series motor and also known as an a.c series motor.

Description : The most suitable servomotor for low power applications is (A) a dc series motor. (B) a dc shunt motor. (C) an ac two-phase induction motor. (D) an ac series motor.

Last Answer : (B) a dc shunt motor.

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : Why shouldn’t a DC shunt motor start on the heavy load setting?

Last Answer : A series motor never started at no load and a shunt motor is never started at on load.

Description : What will happen when a DC shunt motor is started with a load?

Last Answer : Starting current will be very high so motor will take more current from supply. It may damage the armature winding.

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : To conduct load test on a dc shunt motor, it is coupled to a generator which is identical to the motor. The field of the generator is also connected to the same supply source as the motor. The armature of generator is ... value of this load resistance is  (A) 1.0 (B) 0.98 (C) 0.96 (D) 0.94

Last Answer : To conduct load test on a dc shunt motor, it is coupled to a generator which is identical to the motor. The field of the generator is also connected to the same supply source as the motor. ... obtain rated armature current in both motor and generator. The p.u value of this load resistance is 0.96

Description : Armature shunting method of speed control of dc shunt motor is preferred over annature resistance method due to:  (1) Better speed regulation (2) Less loss in external resistance (3) Simplicity in control circuit (4) Reduced cost of controller

Last Answer : Armature shunting method of speed control of dc shunt motor is preferred over annature resistance method due to: Better speed regulation.

Description : The counter EMF of a DC motor is maximum when the _________. A. motor is at rated speed B. armature is not turning C. motor is almost up to rated speed D. armature has just begun to turn

Last Answer : Answer: A

Description : The counter EMF produced in the windings of a DC motor is 'zero' when the ____________. A. armature has just begun to turn B. armature is not turning C. motor is almost up to rated speed D. motor is at rated speed

Last Answer : Answer: B

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : A dc series motor driving and electric train faces a constant power load. It is running at rated speed and rated voltage. If the speed has to be brought down to 0.25 p.u. the supply voltage has to be approximately brought down to  (A) 0.75 p.u (B) 0.5 p.u (C) 0.25 p.u (D) 0.125 p.u

Last Answer : A dc series motor driving and electric train faces a constant power load. It is running at rated speed and rated voltage. If the speed has to be brought down to 0.25 p.u. the supply voltage has to be approximately brought down to 0.5 p.u

Description : As shown in the illustration, when the 'speed control' system is in 'SPLIT' _______________. EL-0096 A. Relays #1, #5 and #8 are not used B. the 'slew rated controller' is grounded through Relay ... E/P converters' are bypassed and air is fed directly to the governors via the 'load sharing valve'

Last Answer : Answer: C