A venturi-flume is used to measure
(A) Pressure of liquid
(B) Discharge of liquid
(C) Pressure difference between two points in a channel
(D) Pressure difference between two points in a pipe

1 Answer

Answer :

Answer: Option B

Related questions

Description : 13. A venturi flume is a flumed structure constructed across a channel by restricting its width. A) True B) False

Last Answer : A

Description : In a venturi-flume, the flow takes place at (A) Atmospheric pressure (B) Gauge pressure (C) Absolute pressure (D) None of these

Last Answer : Answer: Option A

Description : A pitot tube is used to measure the (A) Velocity of flow at the required point in a pipe (B) Pressure difference between two points in a pipe (C) Total pressure of liquid flowing in a pipe (D) Discharge through a pipe

Last Answer : Answer: Option A

Description : Venturimeter is used to (A) Measure the velocity of a flowing liquid (B) Measure the pressure of a flowing liquid (C) Measure the discharge of liquid flowing in a pipe (D) Measure the pressure difference of liquid flowing between two points in a pipe line

Last Answer : Answer: Option C

Description : The coefficient of venturi-flume, generally, lies between (A) 0.3 to 0.45 (B) 0.50 to 0.75 (C) 0.75 to 0.95 (D) 0.95 to 1.0

Last Answer : Answer: Option D

Description : Barometer is used to measure (A) Velocity of liquid (B) Atmospheric pressure (C) Pressure in pipes and channels (D) Difference of pressure between two points in a pipe

Last Answer : Answer: Option B

Description : A water channel supported above the ground over trestles, is generally called  (A) Flume  (B) Canal  (C) Aqueduct  (D) Tunnel 

Last Answer : (A) Flume

Description : Most important method for calculating discharge for planning a water supply project, is  (A) Velocity area method  (B) Weir or spillway method  (C) Use of venturi-meter  (D) Using power plant consumption 

Last Answer : (A) Velocity area method

Description : Select the wrong statement pertaining to flow of an incompressible fluid through a Venturimeter. (A) For frictionless flow, the fluid pressure entering the venturi meter will be exactly equal ... than an orificemeter (D) Venturimeter incurs less power loss compared to an equivalent orificemeter

Last Answer : (C) Venturimeter occupies less space than an orificemeter

Description : A differential manometer is used to measure (A) Atmospheric pressure (B) Pressure in pipes and channels (C) Pressure in Venturimeter (D) Difference of pressures between two points in a pipe

Last Answer : Answer: Option D

Description : Piezometer is used to measure (A) Pressure in pipe, channels etc. (B) Atmospheric pressure (C) Very low pressures (D) Difference of pressure between two points

Last Answer : Answer: Option C

Description : A manometer is used to measure (A) Atmospheric pressure (B) Pressure in pipes and channels (C) Pressure in Venturimeter (D) Difference of pressures between two points in a pipe

Last Answer : Answer: Option B

Description : Hot wire anemometer is used to measure (A) Pressure in gases (B) Liquid discharge (C) Pressure in liquids (D) Gas velocities

Last Answer : Answer: Option D

Description : Which of the following statement is wrong? (A) A flow whose streamline is represented by a curve is called two dimensional flow. (B) The total energy of a liquid particle is the sum of potential energy, ... (D) A pitot tube is used to measure the velocity of flow at the required point in a pipe.

Last Answer : Answer: Option C

Description : The pressure and velocity at the throat of a Venturi tube, measuring the flow of a liquid, are related to the upstream pressure and velocity, respectively, as follows: (A) Pressure is lower but ... velocity is lower (C) Both pressure and velocity are lower (D) Pressure and velocity are identical

Last Answer : The pressure and velocity at the throat of a Venturi tube, measuring the flow of a liquid, are related to the upstream pressure and velocity, respectively, as follows: (A) Pressure is lower but ... lower (C) Both pressure and velocity are lower (D) Pressure and velocity are identical

Description : The maximum discharge through a circular channel takes place, when the depth of the fluid flow is __________ times the pipe diameter. (A) 0.25 (B) 0.5 (C) 0.66 (D) 0.95

Last Answer : (D) 0.95

Description : The flow in a pipe or channel is said to be non-uniform when (A) The liquid particles at all sections have the same velocities (B) The liquid particles at different sections have different ... The quantity of liquid flowing per second is constant (D) Each liquid particle has a definite path

Last Answer : Answer: Option B

Description : The flow in a pipe or channel is said to be uniform when (A) The liquid particles at all sections have the same velocities (B) The liquid particles at different sections have different ... The quantity of liquid flowing per second is constant (D) Each liquid particle has a definite path

Last Answer : Answer: Option A

Description : Venturi meter is used to measure water, if

Last Answer : Ans.Water flow from the pipe

Description : A weir is used to measure the large water discharge rate from a river or from an open channel. A weir is not of __________ shape. (A) Circular (B) Rectangular (C) Triangular (D) Trapezoidal

Last Answer : (A) Circular

Description : In case of unsteady fluid flow, conditions & flow pattern change with the passage of time at a position in a flow situation. Which of the following is an example of unsteady flow? (A) ... level is maintained (D) Low velocity flow of a highly viscous liquid through a hydraulically smooth pipe

Last Answer : (B) Water flow in the suction and discharge pipe of a reciprocating pump

Description : Which of the following is not the function of a volute casing provided in a centrifugal pump? (A) To reduce the head loss in discharge (B) To increase the pump efficiency (C) To collect liquid ... and to transmit it to the delivery pipe at constant velocity (D) To increase the pump discharge rate

Last Answer : Option D

Description : Sele(A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement. (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meterct the correct statement

Description : Select the correct statement. (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter (B) A Venturimeter with a given gage difference discharges at a ... a given pipe line, whether a Venturimeter or a nozzle with the same throat dia is used

Last Answer : (A) The discharge through a Venturimeter depends upon Δp only and isindependent of orientation of the meter

Description : Which of the following equipments is not used for liquid dispersion? (A) Wetted wall towers (B) Packed towers (C) Venturi scrubbers (D) Agitated vessels

Last Answer : (D) Agitated vessels

Description : Which of the following equipments is used for liquid dispersion? (A) Packed column (B) Venturi scrubber (C) Bubble cap plate column (D) Wetted wall column

Last Answer : Option B

Description : A notch is used to measure __________ of liquids. (A) Pressure (B) Discharge (C) Velocity (D) Volume

Last Answer : Answer: Option B

Description : A compound pipe is required to be replaced by a new pipe. The two pipes are said to be equivalent, if (A) Length of both the pipes is same (B) Diameter of both the pipes is same (C) Loss of ... discharge of both the pipes is same (D) Loss of head and velocity of flow in both the pipes is same

Last Answer : Answer: Option C

Description : If Q is discharge is cubic metres per sec and D is the economical diameter of the pipe. According to Lea (A) D = 0.67 to 0.87 Q (B) D = 0.77 to 0.97 Q (C) D = 0.97 to 1.22 Q (D) D = 1.22 to 1.33 Q

Last Answer : (C) D = 0.97 to 1.22 Q

Description : Pick up the correct statement from the following:  (A) Deposition of calcium carbonate on the inside of the well pipe, causes incrustation of the  pipe  (B) Incrustation of the pipe reduces the discharge  (C) Acidic waters cause corrosion of the pipes  (D) All the above 

Last Answer : (D) All the above 

Description : If discharge of a pump is 0.16 cumecs, the economic diameter of pipe, is  (A) 0.488 m  (B) 4.88 cm  (C) 48.8 cm  (D) 4.88 m 

Last Answer : (A) 0.488 m 

Description : For calculation of economical diameter D of a pipe in metres for a discharge Q to be pumped in  cumecs, Lea suggested the empirical formula  (A) D = 0.22 Q (B) D = 1.22 Q (C) D = 2.22 Q (D) D = 3.22 Q

Last Answer : (B) D = 1.22 Q

Description : Select the wrong statement (A) An equivalent pipe is treated as an ordinary pipe for all calculations (B) The length of an equivalent pipe is equal to that of a compound pipe (C) The discharge ... of a compound pipe (D) The diameter of an equivalent pipe is equal to that of a compound pipe

Last Answer : Answer: Option D

Description : 149 The power transmitted through a pipe is (where w = Specific weight in N/m3 , and Q = Discharge in m 3 /s) (A) w × Q × H (B) w × Q × hf (C) w × Q (H - hf ) (D) w × Q (H + hf )

Last Answer : Answer: Option C

Description : Consider the following statements in respect of steady laminar flow through a circular pipe: 1. Shear stress is zero on the central axis of the pipe 2. Discharge varies directly with the viscosity of the fluid 3. Velocity is maximum at the ... 2 , 3 & 4 (b) 1 & 3 only (c) 2 & 4 only (d)3 & 4 only

Last Answer : (b) 1 & 3 only

Description : The coefficient of discharge for an external mouthpiece depends upon (A) Velocity of liquid (B) Pressure of liquid (C) Area of mouthpiece (D) Length of mouthpiece

Last Answer : Answer: Option D

Description : m and n are monsoon duration factor and catchment factor respectively. If P is yearly rainfall in  cm, runoff can be calculated by  (A) Velocity area method  (B) Weir or spillway method  (C) Use of venturi-meter  (D) Using power plant consumption 

Last Answer : (A) Velocity area method 

Description : Manometer is used to measure (A) Pressure in pipes, channels etc. (B) Atmospheric pressure (C) Very low pressure (D) Difference of pressure between two points

Last Answer : Answer: Option A

Description : Barometer is used to measure (A) Pressure in pipes, channels etc. (B) Atmospheric pressure (C) Very low pressure (D) Difference of pressure between two points

Last Answer : Answer: Option B

Description : Differential manometer is used to measure (A) Pressure in pipes, channels etc. (B) Atmospheric pressure (C) Very low pressure (D) Difference of pressure between two points

Last Answer : Answer: Option D

Description : Air valves are generally provided in pressure pipes of water supply  (A) At pipe junctions  (B) At summits  (C) At low points  (D) Near service pipes 

Last Answer : (B) At summits 

Description : A 2" gate valve fitted in a pipe is replaced by a similar globe valve. Pressure drop in gate valve was Δp. For the same discharge, the pressure drop across globe valve is (A) Δp (B) < Δp (C) > Δp (D) Δp

Last Answer : (C) > Δp

Description : Discharge in laminar flow through a pipe varies (A) As the square of the radius (B) Inversely as the pressure drop (C) Inversely as the viscosity (D) As the square of the diameter

Last Answer : (A) As the square of the radius

Description : Permanent pressure loss in a well designed Venturimeter is about __________ percent of the venturi differential. (A) 1 (B) 10 (C) 30 (D) 50

Last Answer : (A) 1

Description : Compare orifice plate with venturi tube with reference to: (i) Working principle (ii) Construction (iii) Cost (iv) Pressure loss

Last Answer : Venturi Flow Meter vs Orifice Plate Meter

Description : Two different channels, M and N, in two different sites are designed based on Lacey's theory, to carry same quantum of discharge. But the bed material of M is found to be finer than that of N. a) ... slope c) Channels M and N can have same longitudinal slopes d) Silting is more in M than in N

Last Answer : b) Channel N will have steeper longitudinal slope

Description : The ratio of rate of change of the discharge of an outlet to the rate of change of the discharge of distributing channel is called (A) Proportionality (B) Flexibility (C) Setting (D) Sensitivity

Last Answer : Answer: Option B

Description : A control meter is preferred to a weir because (A) It measures the discharge even in silt Leiden streams (B) The velocity of approach of the channel increases above the control, and thus removes the silt completely (C) It is not damaged by floating debris (D) All the above

Last Answer : Answer: Option D

Description : channel is said to be of most economical cross-section, if (A) It gives maximum discharge for a given cross-sectional area and bed slope (B) It has minimum wetted perimeter (C) It involves lesser excavation for the designed amount of discharge (D) All of the above

Last Answer : Answer: Option D

Description : According to Chezy's formula, the discharge through an open channel is (where A = Area of flow, C = Chezy's constant, m = Hydraulic mean depth, and i = Uniform slope in bed) (A) A × m × i) (B) C × m × i) (C) AC × m × i) (D) mi × A × C)

Last Answer : Answer: Option C