When sizing a cooling tower the highest anticipate__________ should be used?
• Dry bulb
• Wet bulb
• Both dry and wet bulb
• None of the above

1 Answer

Answer :

Wet bulb

Related questions

Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach

Last Answer : Approach

Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above

Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour

Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above

Last Answer : All of the above

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : The cooling water reduces the water temperature close to _____. • Dry bulb temperature • Ambient wet bulb temperature • Dew point temperature • None of the above

Last Answer : Ambient wet bulb temperature

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these

Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower

Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high

Last Answer : (B) No

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these

Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : When specifying a cooling tower, should I look up historic wet bulb temperatures for my area or should I take measurements?

Last Answer : If this is a new installation, look up historical wet bulb temperatures for area and be sure to report them to the cooling tower manufacturer as ambient wet bulb temperatures . The ... the tower entrance. The entering wet bulb temperature always higher than the ambient wet bulb temperature.

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : . Most cooling towers are capacity rated at a "standard" wet bulb temperature of ___of • 72°F • 52°F • 78°F • 75°F

Last Answer : 78°F

Description : Which of the following psychrometric processes is followed by water vapour laden unsaturated air, when it is passed through solid or liquid adsorbent? (A) Cooling and dehumidification ... (C) Dehumidification with dry bulb temperature remaining constant (D) None of these

Last Answer : (B) Heating and dehumidification at almost constant wet bulb temperature

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : During sensible cooling process (A) Relative humidity decreases (B) Relative humidity increases (C) Wet bulb temperature decreases (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : The cooling effect in a cooling tower cannot be increased by (A) Increasing the air velocity over the wet surfaces (B) Reducing the humidity of entering air (C) Lowering the barometric pressure (D) None of these

Last Answer : (D) None of these

Description : The cooling effect in a cooling tower can be speeded up by (A) Increasing the air velocity and area of exposed wet surface (B) Reducing the barometric pressure (C) Reducing the humidity of the air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these

Last Answer : (D) None of these

Description : During sensible cooling of air, its wet bulb temperature (A) Decreases but dew point remains constant (B) Increases but dew point remains constant (C) Increases & the dew point decreases (D) Decreases & the dew point increases

Last Answer : (B) Increases but dew point remains constant

Description : Cooling tower is a ______device a) Heat absorption b) heat rejection c) Both a and b c) neither a nor b

Last Answer : heat rejection

Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong

Last Answer : cooling tower

Description : Which temperature can be measured by an instrument called psychrometer? A. dry bulb temperature B. wet bulb temperature C. both a. and b. D. none of the above

Last Answer : ANSWER : C

Description : Dry bulb temperature of unsaturated air is more than its __________ temperature. (A) Dew point (B) Wet bulb (C) Both 'a' & 'b' (D) Neither 'a' nor 'b

Last Answer : (C) Both 'a' & 'b

Description : In case of unsaturated air (A) Dew point < wet bulb temperature (B) Wet bulb temperature < dry bulb temperature (C) Both (A) and (B) (D) Neither (A) not (B)

Last Answer : (C) Both (A) and (B)

Description : Unsaturated air (with dry and wet bulb temperatures being 35 and 25°C respectively) is passed through water spray chamber maintained at 35°C. The air will be (A) Cooled (B) Humidified (C) Both (A) & (B) (D) Dehumidified

Last Answer : (B) Humidified

Description : During sensible heating of humid air (A) Relative humidity increases (B) Dew point remains constant (C) Dry bulb & wet bulb temperature increases (D) Both 'b' & 'c'

Last Answer : (D) Both 'b' & 'c'

Description : A sling psychrometer is used to measure : a) only dry bulb temperature b) only wet bulb temperature c) both a & b d) relative humidity

Last Answer : c) both a & b

Description : In sensible heating or cooling, A. work done remains constant B. dry bulb temperature or air remains constant C. both of the mentioned D. none of the mentioned

Last Answer : ANSWER : A

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : Pollution caused by cooling tower includes 1. Fouling 2. Limestone formation 3. Corrosion 4. All of above

Last Answer : All of above

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called a) Liquid gas ratio b) Cycle of concentration c) Cooling tower effectiveness d) None of the above

Last Answer : Cycle of concentration

Description : Cooling tower effectiveness is the ratio of a) Range/( Range + approach) b) Approach/(range + approach) c) Range /(range - approach) d) Approach/ /(range - approach)

Last Answer : Range/( Range + approach)

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station