During dehumidification of unsaturated air wet bulb temperature &

partial pressure of vapor are not constant. However, during evaporative

cooling process with recirculated water supply, the __________ remains

constant.

(A) Wet bulb temperature

(B) Partial pressure of water vapor

(C) Relative humidity

(D) None of these

1 Answer

Answer :

(A) Wet bulb temperature

Related questions

Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these

Last Answer : (D) None of these

Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : Which of the following psychrometric processes is followed by water vapour laden unsaturated air, when it is passed through solid or liquid adsorbent? (A) Cooling and dehumidification ... (C) Dehumidification with dry bulb temperature remaining constant (D) None of these

Last Answer : (B) Heating and dehumidification at almost constant wet bulb temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : Which of the following parameters remains constant during chemical dehumidification? (A) Dry bulb temperature (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (A) Dry bulb temperature

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : During sensible heating of humid air (A) Relative humidity increases (B) Dew point remains constant (C) Dry bulb & wet bulb temperature increases (D) Both 'b' & 'c'

Last Answer : (D) Both 'b' & 'c'

Description : On a day when the partial pressure of water vapor remains constant, what happens as the temperature rises?  a. the relative humidity increases  b. the relative humidity decreases  c. the relative humidity remains constant  d. the air would eventually become saturated

Last Answer : the relative humidity decreases

Description : __________ temperature remains constant during adiabatic saturation process of unsaturated air. (A) Dew point (B) Dry bulb (C) Wet bulb (D) None of these

Last Answer : (C) Wet bulb

Description : With increase in absolute humidity, the dew point of an unsaturated mixture of air and water vapor (at constant pressure and temperature). (A) Increases (B) Remains unchanged (C) Decreases (D) Decreases linearly

Last Answer : (A) Increases

Description : In chemical dehumidification process (A) Wet bulb temperature increases (B) Dry bulb temperature remains constant (C) Dew point temperature increases (D) Dry bulb temperature increases

Last Answer : Option B

Description : Which of the following can be calculated theoretically using steam table and Dalton's law of partial pressure; if the relative humidity and dry bulb temperature of moist air is known? (A) Dew point (B) Humidity ratio (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : Unsaturated air (with dry bulb temperature and dew point being 35°C and 18°C respectively) is passed through a water spray chamber maintained at 15°C. The air will be cooled (A) And ... (C) At the same relative humidity (D) And dehumidified with decrease in wet bulb temperature

Last Answer : (D) And dehumidified with decrease in wet bulb temperature

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : During sensible cooling process (A) Relative humidity decreases (B) Relative humidity increases (C) Wet bulb temperature decreases (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : When an unsaturated air-water mixture is heated at constant pressure, then (A) The partial pressure of water vapour increases (B) The specific humidity decreases (C) The relative humidity increases (D) The relative humidity decreases

Last Answer : D) The relative humidity decreases

Description : When dry bulb temperature & wet bulb temperature of moist air is the same, it means that the (A) Partial pressure of water vapour is less than the total pressure (B) Humidity is < 100% & dew ... Dew point temperature of air has not reached & air is not saturated fully (D) Air is fully saturated

Last Answer : (D) Air is fully saturated

Description : During sensible cooling of air, its wet bulb temperature (A) Decreases but dew point remains constant (B) Increases but dew point remains constant (C) Increases & the dew point decreases (D) Decreases & the dew point increases

Last Answer : (B) Increases but dew point remains constant

Description : Air initially at 101. 3 kPa and 40°C and with a relative humidity of 50%, is cooled at constant pressure to 30°C. The cooled air has a (A) Higher dew point (B) Higher absolute (specific) humidity (C) Higher relative humidity (D) Higher wet bulb temperature

Last Answer : (C) Higher relative humidity

Description : Which of the following remains constant during sensible cooling process? (A) Specific humidity (B) Partial pressure of vapour (C) Both (A) and (B)

Last Answer : (C) Both (A) and (B)

Description : . In chemical dehumidification of air (A) Both specific humidity & dry bulb temperature increases (B) Both specific humidity & dry bulb temperature decreases (C) Specific humidity decreases & dry bulb temperature increases (D) Specific humidity increases & dry bulb temperature decreases

Last Answer : (C) Specific humidity decreases & dry bulb temperature increases

Description : The wet bulb temperature is lower in dry air than in wet air at the same temperature. A dry bulb thermometer registers a higher temperature than a wet bulb thermometer except at __________ percent relative humidity. (A) 0 (B) 100 (C) 50 (D) None of these

Last Answer : Option B

Description : The dew point of moist air becomes __________ with decrease in its relative humidity. (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) More than the dry bulb temperature (D) Equal to wet bulb temperature

Last Answer : Option A

Description : The dew point temperature lines on psychrometric charts are straight inclined sloping downwards to the right. When relative humidity of moist air is 100%, then (A) Wet bulb temperature=dry bulb temperature (B) ... temperature (C) Saturation temperature=dew point temperature (D) All 'a', 'b' & 'c

Last Answer : Option D

Description : High relative humidity decreases the evaporative process and as the temperature is increased, the relative humidity decreases. The comfort range for human body is the ambient temperature of 22 to 27°C with relative humidity ranging from __________ ... to 10 (B) 15 to 25 (C) 45 to 50 (D) 75 to 80

Last Answer : (C) 45 to 50

Description : _________is the partial pressure of water vapor at the existing temperature divided by the equilibrium vapor pressure of water at the existing temperature.  a. vacuum pressure  b. relative humidity  c. absolute pressure  d. vapor pressure

Last Answer : relative humidity

Description : __________ is the temperature at which a gas-vapor mixture becomes saturated, when cooled at constant total pressure out of contact with a liquid. (A) Dew point (B) Bubble point (C) Dry bulb temperature (D) Wet bulb temperature

Last Answer : (A) Dew point

Description : Dry-bulb temperature is: a. The absolute temperature corresponding to the atmospheric pressure b. The same as the wet-bulb temperature if the relative humidity is less than 100% c. Not required ... d. The temperature of the air measured with an ordinary thermometer e. The dew point temperature

Last Answer : Answer: D

Description : Dry bulb temperature of unsaturated air is more than its __________ temperature. (A) Dew point (B) Wet bulb (C) Both 'a' & 'b' (D) Neither 'a' nor 'b

Last Answer : (C) Both 'a' & 'b

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : Unsaturated air (with dry bulb and wet bulb temperatures being 45°C and 25°C respectively) is passed through a water spray chamber maintained at 23°C. The air will be cooled and (A) ... temperature decreasing B) Humidified at constant wet bulb temperature (C) Dehumidified (D) None of these

Last Answer : (A) Humidified with wet bulb temperature decreasing

Description : At 100% relative humidity, the dew point temperature of moist air is (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) Equal to the wet bulb temperature (D) Equal to the ambient temperature

Last Answer : (B) More than the wet bulb temperature

Description : Wet-bulb temperature is: a. The temperature indicated by a thermometer whose bulb covered by a water-wetted wick and exposed to a rapidly moving stream of air b. The same as the dry-bulb ... point temperature d. Always less than the dry-bulb temperature e. Not required to find the relative humidity

Last Answer : Answer: A

Description : Relative humidity is a) the ratio of water vapour in the air compared to the total amount water vapour the air could contain at a given temperature b) equal to the dry bulb temperature divided by the wet bulb ... of dry air e) the ratio of the mass of water vapour divided by the mass of wet air

Last Answer : ANSWER : A

Description : In sensible cooling process the relative humidity: A. decreases B. increases C. remains constant D. none of the above

Last Answer : ANSWER : B

Description : A sling psychrometer is used to measure : a) only dry bulb temperature b) only wet bulb temperature c) both a & b d) relative humidity

Last Answer : c) both a & b

Description : Dew point of an air-water vapor mixture (A) Decreases with decrease in pressure (B) At constant humidity & total pressure is fixed (C) Corresponding to any point on the humidity chart is obtained by projecting a ... to the temperature axis and to the saturation curve (D) All 'a', 'b' & 'c'

Last Answer : (D) All 'a', 'b' & 'c'

Description : At a fixed pressure, the humidity depends upon the partial pressure of vapor in the mixture. Humidity of a vapour free gas is __________ percent. (A) 100 (B) 0 (C) 50 (D) Between 0 and 100

Last Answer : (B) 0

Description : gas which is collected over water becomes moistened due to water vapor, exerts its own partial pressure at the gas temperature, which is termed as its (A) Aqueous tension (B) Saturated humidity (C) Vapor pressure

Last Answer : Option A

Description : What is the relative humidity when the dry bulb temperature is 16 and the wet bulb is 14 celcius?

Last Answer : Feel Free to Answer

Description : Sling psychrometer is used to measure A. only dry bulb temperature B. only wet bulb temperature C. dry and wet bulb temperature D. relative humidity

Last Answer : ANSWER : C

Description : At 100% relative humidity, the wet bulb temperature is A. lower than the dew point temperature B. higher than the dew point temperature C. equal to the dew point temperature D. none of the above

Last Answer : ANSWER : C

Description : Unsaturated air (with dry and wet bulb temperatures being 35 and 25°C respectively) is passed through water spray chamber maintained at 35°C. The air will be (A) Cooled (B) Humidified (C) Both (A) & (B) (D) Dehumidified

Last Answer : (B) Humidified

Description : __________ temperature is the steady state temperature attained by a small amount of liquid evaporating into a large quantity of unsaturated gas￾vapor mixture. (A) Dry bulb (B) Wet bulb (C) Dew point (D) None of these

Last Answer : (B) Wet bulb

Description : Steady state temperature reached by a small amount of liquid evaporating into a large amount of unsaturated vapour-gas mixture is called the __________ temperature. (A) Dry-bulb (B) Wet-bulb (C) Dew point (D) Adiabatic saturation

Last Answer : (B) Wet-bulb