Which of the following processes is followed by unsaturated air (with

dry bulb temperature 12°C and relative humidity 47%) passing through

water spray washer (temperature of water being constant at 40°C?

(A) Humidification only

(B) Heating only

(C) Both heating and humidification

(D) Evaporative cooling

1 Answer

Answer :

(C) Both heating and humidification

Related questions

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : Which of the following psychrometric processes is followed by water vapour laden unsaturated air, when it is passed through solid or liquid adsorbent? (A) Cooling and dehumidification ... (C) Dehumidification with dry bulb temperature remaining constant (D) None of these

Last Answer : (B) Heating and dehumidification at almost constant wet bulb temperature

Description : Unsaturated air (with dry bulb temperature and dew point being 35°C and 18°C respectively) is passed through a water spray chamber maintained at 15°C. The air will be cooled (A) And ... (C) At the same relative humidity (D) And dehumidified with decrease in wet bulb temperature

Last Answer : (D) And dehumidified with decrease in wet bulb temperature

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these

Last Answer : (D) None of these

Description : Unsaturated air (with dry bulb and wet bulb temperatures being 45°C and 25°C respectively) is passed through a water spray chamber maintained at 23°C. The air will be cooled and (A) ... temperature decreasing B) Humidified at constant wet bulb temperature (C) Dehumidified (D) None of these

Last Answer : (A) Humidified with wet bulb temperature decreasing

Description : Air initially at 101. 3 kPa and 40°C and with a relative humidity of 50%, is cooled at constant pressure to 30°C. The cooled air has a (A) Higher dew point (B) Higher absolute (specific) humidity (C) Higher relative humidity (D) Higher wet bulb temperature

Last Answer : (C) Higher relative humidity

Description : During sensible heating of humid air (A) Relative humidity increases (B) Dew point remains constant (C) Dry bulb & wet bulb temperature increases (D) Both 'b' & 'c'

Last Answer : (D) Both 'b' & 'c'

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : Unsaturated air (with dry and wet bulb temperatures being 35 and 25°C respectively) is passed through water spray chamber maintained at 35°C. The air will be (A) Cooled (B) Humidified (C) Both (A) & (B) (D) Dehumidified

Last Answer : (B) Humidified

Description : An air-water vapour mixture has a dry bulb temperature of 60°C and a dew point temperature of 40°C. The total pressure is 101.3 kPa and the vapour pressure of water at 40°C and 60°C are 7.30 kPa and 19.91 kPa respectively ... air is: (A) 0.048 (B) 0.079 (C) 0.122 (D) 0.152

Last Answer : (D) 0.152

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : Evaporative cooling process employs a combination of cooling and humidification in which the (A) Sensible heat is added (B) Sensible heat is removed and the latent heat is added (C) Latent heat is removed (D) Sensible heat is added and latent heat is removed

Last Answer : Option B

Description : Humidification is the process of addition moisture in air at A. constant wet bulb temperature B. constant dry bulb temperature C. constant latent heat D. none of the above

Last Answer : ANSWER : B

Description : In sensible heating or cooling, A. work done remains constant B. dry bulb temperature or air remains constant C. both of the mentioned D. none of the mentioned

Last Answer : ANSWER : A

Description : During sensible cooling process (A) Relative humidity decreases (B) Relative humidity increases (C) Wet bulb temperature decreases (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in ... (A) Molal (B) Relative (C) Percentage (D) None of these

Last Answer : (A) Mola

Description : Which of the following can be calculated theoretically using steam table and Dalton's law of partial pressure; if the relative humidity and dry bulb temperature of moist air is known? (A) Dew point (B) Humidity ratio (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : The wet bulb temperature is lower in dry air than in wet air at the same temperature. A dry bulb thermometer registers a higher temperature than a wet bulb thermometer except at __________ percent relative humidity. (A) 0 (B) 100 (C) 50 (D) None of these

Last Answer : Option B

Description : The dew point of moist air becomes __________ with decrease in its relative humidity. (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) More than the dry bulb temperature (D) Equal to wet bulb temperature

Last Answer : Option A

Description : The dew point temperature lines on psychrometric charts are straight inclined sloping downwards to the right. When relative humidity of moist air is 100%, then (A) Wet bulb temperature=dry bulb temperature (B) ... temperature (C) Saturation temperature=dew point temperature (D) All 'a', 'b' & 'c

Last Answer : Option D

Description : When an unsaturated air-water mixture is heated at constant pressure, then (A) The partial pressure of water vapour increases (B) The specific humidity decreases (C) The relative humidity increases (D) The relative humidity decreases

Last Answer : D) The relative humidity decreases

Description : __________ temperature remains constant during adiabatic saturation process of unsaturated air. (A) Dew point (B) Dry bulb (C) Wet bulb (D) None of these

Last Answer : (C) Wet bulb

Description : Wet-bulb temperature is: a. The temperature indicated by a thermometer whose bulb covered by a water-wetted wick and exposed to a rapidly moving stream of air b. The same as the dry-bulb ... point temperature d. Always less than the dry-bulb temperature e. Not required to find the relative humidity

Last Answer : Answer: A

Description : Relative humidity is a) the ratio of water vapour in the air compared to the total amount water vapour the air could contain at a given temperature b) equal to the dry bulb temperature divided by the wet bulb ... of dry air e) the ratio of the mass of water vapour divided by the mass of wet air

Last Answer : ANSWER : A

Description : High relative humidity decreases the evaporative process and as the temperature is increased, the relative humidity decreases. The comfort range for human body is the ambient temperature of 22 to 27°C with relative humidity ranging from __________ ... to 10 (B) 15 to 25 (C) 45 to 50 (D) 75 to 80

Last Answer : (C) 45 to 50

Description : A sling psychrometer is used to measure : a) only dry bulb temperature b) only wet bulb temperature c) both a & b d) relative humidity

Last Answer : c) both a & b

Description : Dry-bulb temperature is: a. The absolute temperature corresponding to the atmospheric pressure b. The same as the wet-bulb temperature if the relative humidity is less than 100% c. Not required ... d. The temperature of the air measured with an ordinary thermometer e. The dew point temperature

Last Answer : Answer: D

Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these

Last Answer : (C) Spray chamber

Description : Sling psychrometer is used to measure A. only dry bulb temperature B. only wet bulb temperature C. dry and wet bulb temperature D. relative humidity

Last Answer : ANSWER : C

Description : The horizontal line in psychrometric chart joining the change of state of air represents A. humidification B. sensible cooling or heating C. sensible cooling or heating with humidification D. sensible cooling or heating with dehumidification

Last Answer : ANSWER : B

Description : When, H1 = Total heat of air entering the coil (heating or cooling) H2 = Total heat of air leaving the coil (heating or cooling) H3 = Total heat of air at the end of ... A. cooling and humidification B. cooling and dehumidification C. heating and humidification D. heating and dehumidification

Last Answer : ANSWER : C

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : Dry bulb temperature of unsaturated air is more than its __________ temperature. (A) Dew point (B) Wet bulb (C) Both 'a' & 'b' (D) Neither 'a' nor 'b

Last Answer : (C) Both 'a' & 'b

Description : In case of unsaturated air (A) Dew point < wet bulb temperature (B) Wet bulb temperature < dry bulb temperature (C) Both (A) and (B) (D) Neither (A) not (B)

Last Answer : (C) Both (A) and (B)

Description : What is the dew-point when the dry bulb temperature is 20C and the relative humidity is 17?

Last Answer : at 17% relative humidity the dew point is -5.8C at a dry bulb of20C

Description : What is the relative humidity when the dry bulb temperature is 16 and the wet bulb is 14 celcius?

Last Answer : Feel Free to Answer

Description : With increase in absolute humidity, the dew point of an unsaturated mixture of air and water vapor (at constant pressure and temperature). (A) Increases (B) Remains unchanged (C) Decreases (D) Decreases linearly

Last Answer : (A) Increases

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : At 100% relative humidity, the dew point temperature of moist air is (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) Equal to the wet bulb temperature (D) Equal to the ambient temperature

Last Answer : (B) More than the wet bulb temperature

Description : . In chemical dehumidification of air (A) Both specific humidity & dry bulb temperature increases (B) Both specific humidity & dry bulb temperature decreases (C) Specific humidity decreases & dry bulb temperature increases (D) Specific humidity increases & dry bulb temperature decreases

Last Answer : (C) Specific humidity decreases & dry bulb temperature increases

Description : For __________ drying, the effects of velocity, temperature and humidity of the gas and the thickness of the solid are the same. (A) Unsaturated surface (B) Constant rate (C) Both (A) and (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) and (B)

Description : When dry bulb temperature & wet bulb temperature of moist air is the same, it means that the (A) Partial pressure of water vapour is less than the total pressure (B) Humidity is < 100% & dew ... Dew point temperature of air has not reached & air is not saturated fully (D) Air is fully saturated

Last Answer : (D) Air is fully saturated

Description : Which of the following terms is used to describe animals that maintain a constant body temperature by producing heat by metabolic oxidations (muscle contractions) and losing excess heat by evaporative cooling? a) poikilotherms b) heterotherms c) homeotherms d) none of these

Last Answer : ANSWER: C -- HOMEOTHERMS

Description : __________ temperature is the steady state temperature attained by a small amount of liquid evaporating into a large quantity of unsaturated gas￾vapor mixture. (A) Dry bulb (B) Wet bulb (C) Dew point (D) None of these

Last Answer : (B) Wet bulb

Description : Steady state temperature reached by a small amount of liquid evaporating into a large amount of unsaturated vapour-gas mixture is called the __________ temperature. (A) Dry-bulb (B) Wet-bulb (C) Dew point (D) Adiabatic saturation

Last Answer : (B) Wet-bulb