The slenderness ratio of a vertical column of square cross- section of 10 cm side and 500 cm long,
is
(A) 117.2
(B) 17.3
(C) 173.2
(D) 137.2

1 Answer

Answer :

(C) 173.2

Related questions

Description : The slenderness ratio of a vertical column of a square cross-section of 2.5 cm sides and 300 cm  length, is  (A) 200  (B) 240  (C) 360  (D) 416

Last Answer : (D) 416

Description : The slenderness ratio of a vertical column of a square cross-section of 2.5 cm sides and 300 cm length, is (a) 240 (b) 416 (c) 360 (d) 400

Last Answer : (b) 416

Description : The slenderness ratio of a vertical column of a square cross-section of 2.5 cm sides and 300 cm length, is (a) 200 (b) 240 (c) 360 (d) 416

Last Answer : (d) 416

Description : Slenderness ratio of a long column, is  (A) Area of cross-section divided by radius of gyration  (B) Area of cross-section divided by least radius of gyration  (C) Radius of gyration divided by area of cross-section  (D) Length of column divided by least radius of gyration 

Last Answer : (D) Length of column divided by least radius of gyration 

Description : The most critical consideration in the design of a rolled steel column carrying axial loads is the (a) Percentage elongation at yield and the net cross-sectional area (b) Critical bending ... at ultimate load (d) Compressive strength based on slenderness ratio and gross cross-sectional area.

Last Answer : (d) Compressive strength based on slenderness ratio and gross cross-sectional area.

Description : A short masonry pillar is 60 cm x 60 cm in cross-section, the core of the pillar is a square whose side is (A) 17.32 cm (B) 14.14 cm (C) 20.00 cm (D) 22.36 cm

Last Answer : (B) 14.14 cm

Description : The slenderness ratio is the ratio of (a) Length of column to least radius of gyration (b) Moment of inertia to area of cross-section (c) Area of cross-section to moment of inertia (d) Least radius of gyration to length of the column

Last Answer : (a) Length of column to least radius of gyration

Description : The ratio of the effective length of a column and minimum radius of gyration of its cross-sectional area, is known (A) Buckling factor (B) Slenderness ratio (C) Crippling factor (D) None of these

Last Answer : (B) Slenderness ratio

Description : If the effective length of a 32 cm diameter R.C.C. column is 4.40 m, its slenderness ratio, is (A) 40 (B) 45 (C) 50 (D) 55

Last Answer : Answer: Option D

Description : A steel rod 1 metre long having square cross section is pulled under a tensile load of 8 tonnes. The  extension in the rod was 1 mm only. If Esteel = 2 × 106  kg/cm2 , the side of the rod, is  (A) 1 cm  (B) 1.5 cm  (C) 2 cm  (D) 2.5 cm 

Last Answer : (C) 2 cm 

Description : The ratio of the effective length of a column and minimum radius of gyration of its cross sectionalarea, is known (a) Buckling factor (b) Slenderness ratio (c) Crippling factor (d) None of these

Last Answer : (b) Slenderness ratio

Description : An R.C.C. column is treated as long if its slenderness ratio is greater than (A) 30 (B) 35 (C) 40 (D) 50

Last Answer : Answer: Option D

Description : The gravitational field at the surface of the moon is one sixth of that at the surface of the earth. A 72 kg man weighs on the surface of the moon a.137.7 N b.250 c.72 N d.420 N e.117.7 N

Last Answer : e. 117.7 N

Description : A short column (30 cm 20 cm) carries a load P1 at 4 cm on one side and another load P2at 8 cm on  the other side along a principal section parallel to longer dimension. If the extreme intensity on  either side is same, the ... to P2 will be  (A) 2/3  (B) 3/2  (C) 8/5  (D) 5/8 

Last Answer : (C) 8/5 

Description : square cross section b/h/h'=400/400/40mm with a reinforcement ratio of p=0.015 is loaded for action forces of axial load plus uniaxial bending.the column is to be made of C25/30 concrete & S-460 steel.check whether the column AB is short or long?

Last Answer : 10001/999900

Description : A column is said to be of medium size if its slenderness ratio is between (A) 20 and 32 (B) 32 and 120 (C) 120 and 160 (D) 160 and 180

Last Answer : (B) 32 and 120

Description : An R.C.C. column is treated as short column if its slenderness ratio is less than (A) 30 (B) 35 (C) 40 (D) 50

Last Answer : Answer: Option D

Description : According to IS: 4561978, minimum slenderness ratio for a short column is (A) Less than 12 (B) Less than 18 (C) Between 18 and 24 (D) More than 24

Last Answer : Answer: Option A

Description : According to IS 456, minimum slenderness ratio for a short concrete column is (a) Less than 12 (b) Between 12 and 18 (c) Between 18 and 24 (d) More than 24

Last Answer : (a) Less than 12

Description : When a column is supported throughout its length either by masonry walls or by construction on all the sides, then its slenderness ratio is (a) Infinite (b) Zero (c ) Reasonably high (d) Low

Last Answer : (b) Zero

Description : According to IS:456-2000, the minimum slenderness ratio for a short column is [ A ] Less than 12 [ B ] Between 12 and 18 [ C ] Less than 18 [ D ] Must be greater than 18

Last Answer : [ A ] Less than 12

Description : A Column is said to be short, when the slenderness ratio is [ A ] Less than 6 [ B ] Less than 12 [ C ] Less than 18 [ D ] None of the above

Last Answer : [ B ] Less than 12

Description : Slenderness ratio of the column is the ratio of [ A ] the effective length to width of column [ B ] the effective length to depth of column [ C ] the effective length to least lateral design [ D ] none of the above

Last Answer : [ C ] the effective length to least lateral design

Description : The length of a column, having a uniform circular cross-section of 7.5 cm diameter and whose ends are hinged, is 5 m. If the value of E for the material is 2100 tonnes/cm2 , the permissible maximum crippling load will be (A) 1.288 tonnes (B) 12.88 (C) 128.8 tonnes (D) 288.0

Last Answer : (B) 12.88

Description : A short column 20 cm 20 cm in section is reinforced with 4 bars whose area of cross section is 20 sq. cm. If permissible compressive stresses in concrete and steel are 40 kg/cm2 and 300 kg/cm2 , the Safe load on ... should not exceed (A) 4120 kg (B) 41,200 kg (C) 412,000 kg (D) None of these

Last Answer : Answer: Option B

Description : If the slenderness ratio for a column is 100, then it is said to be a __________ column. (a) Long (b) medium (c)short (d) big

Last Answer : (a) Long

Description : A steel column is a long column when the slenderness ratio is (a) >120 (b) 30 (d) None

Last Answer : (a) >120

Description : A column whose slenderness ratio is greater than 120 is known as (a) Short column (b) Long column (c) Medium column (d) Composite column

Last Answer : (b) Long column

Description : Best side slope for most economical trapezoidal section in open channel flow, wherein side slopes are defined by : X horizontal to 1 vertical, is when X equals : (a) 0.404 (b) 0.500 (c) 0.577 (d) 0.673

Last Answer : (c) 0.577

Description : A column is said to be of medium size if its slenderness ratio is between (a) 20 and 32 (b) 32 and 120 (c) 120 and 160 (d) 160 and 180

Last Answer : (b) 32 and 120

Description : A steel column is a medium column when the slenderness ratio is (a) >120 (b) 30 (d) None

Last Answer : (c) >30

Description : A steel column is a short column when the slenderness ratio is (a) >120 (b) 30 (d) None

Last Answer : (b)

Description : Euler’s formula is not valid for mild steel column when slenderness ratio is (a) More than 100 (b) Less than 100 (c) Less than 80 (d)More than 80

Last Answer : (c) Less than 80

Description : The moment of inertia of a hollow circular section whose external diameter is 8 cm and interial diameter is 6 cm about the axis passing through its centre is a.66.8 cm4 b.137.5 cm4 c.550 cm4 d.33.4 cm4 e.275 cm4

Last Answer : b. 137.5 cm4

Description : The polar moment of inertia of a hollow circular section whose external diameter is 8 cm and internal diameter of 6 cm will be a.137.5 cm4 b.107 dynes c.275 cm4 d.550 cm4 e.1100 cm4

Last Answer : c. 275 cm4

Description : Which one of the following is the correct ratio of plastic moment to yield moment for a simply supported beam of uniform square cross section throughout the span (a) 1.5 (b) 1.7 (c) 2.0 (d) 2.34

Last Answer : (a) 1.5

Description : The length of a column, having a uniform circular cross-section of 7.5 cm diameter and whose endsare hinged, is 5 m. If the value of E for the material is 2100 tonnes/cm2, the permissible maximumcrippling load will be (a) 1.288 tonnes (b) 12.88 (c) 128.8 tonnes (d) 288.0

Last Answer : (b) 12.88

Description : 15 17 21 29 45 77 ? a) 109 b) 125 c) 141 d) 173 e) None of these

Last Answer : 15 + 2 = 17 17 + 4 = 21 21 + 8 = 29 29 + 16 = 45 45 + 32 = 77 77 + 64 = 141 Answer: c)

Description : The slenderness ratio for masonry walls should not be more than (A) 10 (B) 20 (C) 30 (D) 40

Last Answer : Answer: Option B

Description : A simply supported wooden beam 150 cm long and having a cross section 16 cm × 24 cm carries a  concentrated load, at the centre. If the permissible stress ft = 75 kg/cm2  and fs= 10 kg/cm2  the safe  load is  (A) 3025 kg  (B) 3050 kg  (C) 3075 kg  (D) 3100 kg 

Last Answer : (C) 3075 kg 

Description : The ratio of the section modulus of a square section of side B and that of a circular section of  diameter D, is  (A) 2 /15  (B) 3 /16  (C) 3 /8  (D) /16

Last Answer : (B) 3 /16 

Description : A square surface 3 m × 3 m lies in a vertical line in water pipe its upper edge at water surface. The hydrostatic force on square surface is (A) 9,000 kg (B) 13,500 kg (C) 18,000 kg (D) 27,000 kg

Last Answer : Answer: Option B

Description : If permissible working stresses in steel and concrete are respectively 1400 kg/cm2 and 80 kg/cm2 and modular ratio is 18, in a beam reinforced in tension side and of width 30 cm and having effective depth 46 cm, the lever arms of the section, is (A) 37 cm (B) 38 cm (C) 39 cm (D) 40 cm

Last Answer : Answer: Option D

Description : For a binary mixture with low relative volatility, continuous rectification to get pure products will require (A) Low reflux ratio (B) Less number of trays (C) Small cross-section column (D) High reflux ratio

Last Answer : (D) High reflux ratio

Description : What is the square foot of 173 x 143 inches?

Last Answer : It is: (173/12) times (143/12) = 172 square feet rounded to thenearest whole number

Description : What is the square foot of 173 x 143 inches?

Last Answer : It is: (173/12) times (143/12) = 172 square feet rounded to thenearest whole number

Description : If a concrete column 200 200 mm in cross-section is reinforced with four steel bars of 1200  mm2  total cross-sectional area. Calculate the safe load for the column if permissible stress in  concrete is 5 N/mm2 ... 15 Ec (A) 264 MN  (B) 274 MN  (C) 284 MN  (D) 294 MN 

Last Answer : (C) 284 MN 

Description : The region of the cross-section of a column in which compressive load may be applied without producing any tensile stress, is known as the core of the cross-section. In circular columns the radius of the core, ... One-third of the radius (C) One-quarter of the radius (D) One-fifth of the radius

Last Answer : (C) One-quarter of the radius

Description : Columns of given length, cross-section and material have different values of buckling loads for different end conditions. The strongest column is one whose (A) One end is fixed and other end is hinged (B) Both ... (C) One end is fixed and the other end entirely free (D) Both the ends are fixed

Last Answer : (D) Both the ends are fixed

Description : The greatest eccentricity which a load W can have without producing tension on the cross-section of a short column of external diameter D and internal diameter d, is (A) 4W/ (D² - d²) (B) (D² - d²)/32D (C) (D² + d²)/8D (D) (D² - d²)/8D

Last Answer : (C) (D² + d²)/8D