What are the types of lighting?

1 Answer

Answer :

a. Direct lighting: light directly comes from the source to the surface. b. Indirect lighting: light reflects from the wall, reflector or ceilings etc. c. Semi direct lighting: light comes through the shade.

Related questions

Description : Which of the listed types of lighting circuits does the diagram shown in the illustration represent? EL-0081 A. High pressure sodium B. Low voltage quartz C. Mercury vapor D. Standard fluorescent

Last Answer : Answer: D

Description : What types of lighting fittings are used in the battery room?

Last Answer : Flame proof acid resistant  

Description : When supplying emergency lighting loads, the storage battery initial voltage must not exceed the standard system voltage by more than _____________. A. 2% B. 3% C. 5% D. 10%

Last Answer : Answer: C

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : Which of the following statements is/are true regarding requirements for receptacle outlets aboard vessels? A. Each receptacle outlet operating at 100 volts or more must have a grounding pole. B. Outlets ... machinery with a portable light having a 50 foot flexible cord. D. All of the above.

Last Answer : Answer: A

Description : Coast Guard Regulations (46 CFR) require that lighting fixture globes must be protected by guards if the fixtures are located in the ____________. A. steering gear room B. galley C. living quarters D. wheelhouse

Last Answer : Answer: A

Description : The source of emergency lighting and power at loss of normal ship's power on a cargo vessel should be obtained from the ______________. A. emergency generator supply to the emergency ... switchboard C. battery supply to the main switchboard D. turbogenerator supply to the emergency switchboard

Last Answer : Answer: A

Description : The purpose of the automatic bus transfer shown in the illustration is to ___________. EL-0014 A. stepdown voltage to the lighting distribution panel B. provide emergency power to ... emergency switchboard from the main switchboard D. provide overcurrent protection to the lighting distribution panel

Last Answer : Answer: B

Description : The electrical schematic shown in the illustration indicates the lighting feeder circuit is _____________. EL-0014 A. three phase, 450 volt, and 60 cycle B. three phase, 120 volt, and 60 cycle C. single phase, 120 volt, and 60 cycle D. not specified

Last Answer : Answer: A

Description : In the lighting distribution circuit shown in the illustration, if all switches are closed and fuse 'F2' were to open, all lights on branches ____________. EL-0013 A. '1', '2', and '3' would go out B. '1' ... and '3' would burn dimly D. '1' and '3' would go out, while branch '2' would remain lit

Last Answer : Answer: D

Description : If the voltage supplied to the lighting circuit is 110 volts, how much current is used by a 100 watt light bulb? A. 0.08 amps B. 0.91 amps C. 1.10 amps D. 90.9 amps

Last Answer : Answer: B

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, Federal Regulations (46 CFR) require the maximum fuse rating for that branch to be _________. EL-0013 A. 80% of the connected load B. 15 amps C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : In the illustration if BRANCH NO. 1 is a lighting circuit for crew's berthing, 46 CFR requires the maximum fuse rating for that branch to be _________. EL-0013 A. 15 amps B. 80% of the connected load C. 20 amps D. 30 amps

Last Answer : Answer: C

Description : If the illustrated lighting branch distribution box is not for cargo or deck lighting, the Coast Guard Regulations (46 CFR) requires the designed load attached to Branch NO.2 to be no more than _________. EL-0013 A. 5 amps B. 16 amps C. 30 amps D. 50 amps

Last Answer : Answer: B

Description : Due to the operating characteristics of the system, time lag fuses (or dual-element fuses) are necessary for use in _____________. A. main lighting circuits B. motor starting circuit C. emergency lighting circuits D. general alarm circuits

Last Answer : Answer: B

Description : Transformers are used onboard ships with AC generators to _____________. A. change frequency B. increase power output to modulating frequency controllers C. decrease power output to modulating frequency ... D. permit higher voltage for electric motor operation and low voltage for lighting circuits

Last Answer : Answer: D

Description : Handheld phase sequence indicators are useful when ________. A. preparing to parallel alternators B. connecting lighting branch circuits C. troubleshooting DC motors D. connecting shore power lines to the ship

Last Answer : Answer: D

Description : Which of the following components are used to assemble a fluorescent lighting system? A. Lamp B. Starter C. Ballast D. All of the above

Last Answer : Answer: D

Description : Time delayed or delayed action-type fuses are designed to _____________. A. prevent grounds in branch circuits B. prevent opens in motor circuits C. permit momentary overloads without melting D. guard lighting and electronic circuits

Last Answer : Answer: C

Description : A delayed-action fuse is most frequently used in which of the listed circuits? A. Lighting circuit B. Motor circuit C. Electric heater circuit D. Radar circuit

Last Answer : Answer: B

Description : The diagram shown in the illustration represents a _________. EL-0058 A. dual speed, 2-winding motor controller B. navigation running light circuit C. single phase, 2-motor selectable starter D. common fluorescent lighting circuit

Last Answer : Answer: B

Description : Where should the lighting arrestor is placed in distribution lines?

Last Answer : Near distribution transformers and out going feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Description : Why Delta Star Transformers are used for Lighting Loads?

Last Answer : A. For lighting loads, neutral conductor is must and hence the secondary must be star winding.This lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star transformer is used for lighting loads.

Description : Why Delta Star transformer Are Used For Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding. and this lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star trformer is used for lighting loads.

Description : Where should the lighting arrestor be placed in distribution lines?

Last Answer : A:Near distribution transformers and out going feeders of 11kv and incomming feeder of 33kv and near power transformers in sub-stations.

Description : Where are the lighting arrestors placed in distribution lines?

Last Answer : Near distribution transformers and outgoing feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Description : Why lighting isolation transformer is req.? 

Last Answer : a) 3 wire to 4 wire conversion, since neutral is required for lighting load. b) Prevents transfer of E/F currents c) Reduces the fault level on secondary side and permits use of small sized cables / CB’s / fuses.

Description : What are the lighting systems adopted in KGS?

Last Answer : There are two systems.  a. Normal lighting with class IV power supply.  b. Emergency lighting with class II power supplies and in control room with class I power supplies. 

Description : Why Delta Star Transformers are used for Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding and this lighting load is always unbalanced in all three phases.  To minimize the current unbalance in the primary we use delta winding in the primary So delta / star transformer is used for lighting loads.

Description : Types of House Lighting?

Last Answer : There are several different types of lighting. In addition to natural lighting, which is a very important part of providing good lighting for your home, there is of course electrical lighting. When ... give the entire room a background level of light. Accent lighting serves a very different purpose

Description : State the different types of outdoor flood lighting and where are they used.

Last Answer : There are three types of projectors used for flood lighting :  a) Narrow beam Projector b) Medium angle Projector c) Wide angle Projector a) Narrow beam Projectors: - Light beam with such ... yards, stadiums, car parking area etc. 3) It is used for illuminating advertisements, boarding's etc.

Description : State the purpose of lighting control. List the different types of dimmer.