Description : Magnet chatter or 'pumping' occurring in a magnetic contactor can be caused by ______________. A. dirt or grease on pole faces B. mechanical interference in the contacts C. chattering contacts on the control relay D. magnetic lock out of the contacts
Last Answer : Answer: C
Description : Where is 2011 Ford Focus door lock relay location?
Last Answer : What is the answer ?
Description : Where is the power door lock relay switch on a 1992 f250?
Last Answer : A door lock relay can be located in four different places on a vehicle, including: Under the dash on the wall by the brake pedal. Under the dash in the middle of the cab behind the stereo. Under the dash behind the passenger air bag.
Description : What is the difference in action of lock out pressure signal on 6.6 kV and 220 kV breakers?
Last Answer : When lock out signal comes to 6.6 kV breakers the breaker will trip. Where as in case of 220 kV breakers the breaker will not trip. If the breaker is open it will be open only and can not be closed. If it is in closed condition it will be closed.
Description : How will a molded-case circuit breaker react after it has tripped, as a result of an overloaded circuit? A. The breaker will trip again if immediately reset. B. The breaker handle will lock in ... down. D. The breaker handle cannot be moved to the OFF position until the thermal element cools down.
Last Answer : Answer: A
Description : If you reverse both the field and the armature connections to a DC propulsion motor, _____________. A. the direction of motor rotation will change B. the brushes will become overheated C. a magnetic lock will occur in the motor D. the direction of motor rotation will remain the same
Last Answer : Answer: D
Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction
Last Answer : Answer: B
Description : What is phase lock mode?
Last Answer : The inverter continuously follows the frequency and phase angle of classIII bus supply.
Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.
Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed
Description : An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the ... C. the alternator was operating out of synchronism D. flashover at the alternator collector rings
Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay
Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed
Description : If a magnetic controller relay fails to drop out when the coil voltage is removed from the relay, the probable cause may be _____________. A. excessive spring tension B. overvoltage C. excessive current D. welded contacts
Description : As shown in the illustration, the circuit has been on the line for several days when component 'E1' burns out. The operator receives an alarm, switches over 'B' to energize the standby ... than required for the circuit therefore limiting the current through the alarm relay which will not pick up
Description : Action carried out by the relay and circuit breaker during fault condition?
Last Answer : Answer: After the relay sensing the fault condition, relay operates and close the trip coils. The effect of this will be circuit breaker operate to open the contacts.
Description : In accordance with Coast Guard Regulations (46 CFR), each battery operated relay-controlled lantern must _____________. A. be readily portable B. contain a dry cell battery having a minimum capacity of ... automatic battery charger to maintain the battery in a fully charged state D. all of the above
Description : As shown in the illustration, once the "LV" relay is energized for operation, what contacts must remain closed to maintain the "LV" relay energized when the control lever is moved away from the "off" or "stop" ... . B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.
Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner
Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater
Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'
Description : A diesel driven emergency generator is prevented from being paralleled with the ship's service generators by __________. A. an electrical interlock system B. an automatic paralleling trip switch C. the synchronizing oscilloscope D. the reverse current relay
Description : Which of the listed procedures is the best way to tell if a motor has become overloaded? A. Measure the current flow and compare it with the motor full load current flow as shown on the nameplate. ... Watch for telltale signs of smoke coming from the motor. D. Periodic opening of the O/L relay coil
Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.
Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.
Description : Which component is responsible for energizing solenoid 'B1-B2' and releasing the brake for the winch motor shown in the illustration? EL-0102 A. Contactor '3M' B. A spring not shown in the schematic diagram C. Resistor 'B2-R1' D. Relay 'FR-B.O.'
Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.
Description : In the illustrated motor controller circuit, which statment is true? EL-0023 A. The high and low speed lights operate at less than line voltage with a resistor in series. B. This controller can be ... . The wattage of the high speed light must be greater than the wattage of the low speed light.
Description : Which of the following statments is true of the illustrated motor controller? EL-0023 A. The low speed is used for starting the motor and when the controller automaticly shifts to High speed. B. The HOL relay ... D. If the overload relay opens for high speed the motor can still be run in low speed.
Description : When paralleling two AC generators, the synchroscope selector switch and frequency meter switch should be set up to sense the frequency of the _____________. A. bus B. generator on the line C. oncoming generator D. bus transfer relay
Description : The motor starts when the start button in the illustration is pushed, but stops when the button is released the trouble is _________. EL-0007 A. the incorrect thermal overload coil B. a faulty 'M' coil C. a dirty contact on the Disc.Sw. at 'L3' D. a faulty holding relay contact
Description : The contacts operated by the D.C. relay coil shown in the illustration are located in the schematic diagram prints at coordinates ____________. EL-0100 A. '41Y' on this page B. '52M52M' and '52H35M' C. '57R' on this page D. '52N' on page '57R'
Description : The operating torque of the upper induction disc-type element, or timer element, of an AC reverse power relay is obtained from ____________. A. the main bus B. a separate battery source C. line voltage D. electromagnets
Description : When the series field relay "FR" of the winch circuit shown in the illustration is energized during dynamic braking the _______________. EL-0102 A. shunt Field Relay "FR-B.O." is de-energized and contacts ... . shunt Field Relay "FR-B.O." opposes the series coil's flux and sets the mechanical brake
Description : The purpose of the reverse power relay, provided on a ship's service alternator panel, is to trip the circuit in the event of ______________. A. main circuit overload B. high power transfer C. generator overspeeding D. alternator motorization
Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield
Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker
Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers
Description : As shown in the illustrations of console schematic diagrams, each circuit card and component, such as a relay or indicating lamp, has an identifier attached. This identifier, which is composed of ... where the item may actually be found on the console by section, surface and possible subassembly
Description : The timer element of a reverse power relay cannot be energized unless _____________. A. the power flow is the same as the tripping direction B. the power flow is the opposite to the tripping direction C. the movement of the disk is damped by a permanent magnet D. one generator is motorized
Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals
Description : When troubleshooting a motor controller, all indications are that a relay coil should be energized. If there were no magnetic pull, with rated voltage measured across the coil, the most probable cause ... open C. auxiliary contact in series with the coil is defective D. relay armature is stuck
Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding
Description : The devices located at coordinates '49W' in the illustration represents a/an _________. EL-0100 A. A.C. motor B. A.C. relay coil C. D.C. motor D. D.C. buzzer
Description : Vessel pitch can be controlled by either the 'bridge or engine room thrust lever' shown in the illustration; but only with one engine on the line whether in 'cruise or maneuver' mode. The cause is most likely a faulty relay _____________. EL-0095 A. #1 B. #2 C. #3 D. #4
Description : The device at coordinates '63/1' in the illustration represents a/an _____________. EL-0100 A. A.C. buzzer B. A.C. motor C. D.C. motor D. D.C. relay coil
Description : If Relay #5 changed contact position grounding the 'auto' input to the 'pitch controller module', pitch control would be effected by the _________________. EL-0095 A. pitch feedback potentiometer B. Engine room thrust split potentiometer C. Engine room thrust lever only D. Bridge thrust lever only
Description : 'A-1', as shown in the illustration, is/are ____________. EL-0017 A. normally-closed overload relay contacts B. a double pole knife switch C. normally-open overload relay contacts D. a single pole knife switch
Description : Power necessary to operate the horn relay shown in the illustration ____________. EL-0093 A. comes from each station's magneto B. is supplied from a 115 volt source C. is conducted through the relay's contacts D. also lights lamps 'R' and 'T'
Description : Equal power factors on paralleled AC generators are maintained by an automatic _____________. A. voltage regulator B. reverse power relay C. reverse current relay D. governor control switch