During sensible cooling process

(A) Relative humidity decreases

(B) Relative humidity increases

(C) Wet bulb temperature decreases

(D) Both (B) and (C)

1 Answer

Answer :

(D) Both (B) and (C)

Related questions

Description : During sensible heating of humid air (A) Relative humidity increases (B) Dew point remains constant (C) Dry bulb & wet bulb temperature increases (D) Both 'b' & 'c'

Last Answer : (D) Both 'b' & 'c'

Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these

Last Answer : (D) None of these

Description : During sensible cooling of air, its wet bulb temperature (A) Decreases but dew point remains constant (B) Increases but dew point remains constant (C) Increases & the dew point decreases (D) Decreases & the dew point increases

Last Answer : (B) Increases but dew point remains constant

Description : In sensible cooling process the relative humidity: A. decreases B. increases C. remains constant D. none of the above

Last Answer : ANSWER : B

Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : Which of the following remains constant during sensible cooling process? (A) Specific humidity (B) Partial pressure of vapour (C) Both (A) and (B)

Last Answer : (C) Both (A) and (B)

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : Air initially at 101. 3 kPa and 40°C and with a relative humidity of 50%, is cooled at constant pressure to 30°C. The cooled air has a (A) Higher dew point (B) Higher absolute (specific) humidity (C) Higher relative humidity (D) Higher wet bulb temperature

Last Answer : (C) Higher relative humidity

Description : Unsaturated air (with dry bulb temperature and dew point being 35°C and 18°C respectively) is passed through a water spray chamber maintained at 15°C. The air will be cooled (A) And ... (C) At the same relative humidity (D) And dehumidified with decrease in wet bulb temperature

Last Answer : (D) And dehumidified with decrease in wet bulb temperature

Description : Which of the following can be calculated theoretically using steam table and Dalton's law of partial pressure; if the relative humidity and dry bulb temperature of moist air is known? (A) Dew point (B) Humidity ratio (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : At 100% relative humidity, the dew point temperature of moist air is (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) Equal to the wet bulb temperature (D) Equal to the ambient temperature

Last Answer : (B) More than the wet bulb temperature

Description : The wet bulb temperature is lower in dry air than in wet air at the same temperature. A dry bulb thermometer registers a higher temperature than a wet bulb thermometer except at __________ percent relative humidity. (A) 0 (B) 100 (C) 50 (D) None of these

Last Answer : Option B

Description : The dew point of moist air becomes __________ with decrease in its relative humidity. (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) More than the dry bulb temperature (D) Equal to wet bulb temperature

Last Answer : Option A

Description : The dew point temperature lines on psychrometric charts are straight inclined sloping downwards to the right. When relative humidity of moist air is 100%, then (A) Wet bulb temperature=dry bulb temperature (B) ... temperature (C) Saturation temperature=dew point temperature (D) All 'a', 'b' & 'c

Last Answer : Option D

Description : A sling psychrometer is used to measure : a) only dry bulb temperature b) only wet bulb temperature c) both a & b d) relative humidity

Last Answer : c) both a & b

Description : What is the relative humidity when the dry bulb temperature is 16 and the wet bulb is 14 celcius?

Last Answer : Feel Free to Answer

Description : Sling psychrometer is used to measure A. only dry bulb temperature B. only wet bulb temperature C. dry and wet bulb temperature D. relative humidity

Last Answer : ANSWER : C

Description : Wet-bulb temperature is: a. The temperature indicated by a thermometer whose bulb covered by a water-wetted wick and exposed to a rapidly moving stream of air b. The same as the dry-bulb ... point temperature d. Always less than the dry-bulb temperature e. Not required to find the relative humidity

Last Answer : Answer: A

Description : Dry-bulb temperature is: a. The absolute temperature corresponding to the atmospheric pressure b. The same as the wet-bulb temperature if the relative humidity is less than 100% c. Not required ... d. The temperature of the air measured with an ordinary thermometer e. The dew point temperature

Last Answer : Answer: D

Description : Relative humidity is a) the ratio of water vapour in the air compared to the total amount water vapour the air could contain at a given temperature b) equal to the dry bulb temperature divided by the wet bulb ... of dry air e) the ratio of the mass of water vapour divided by the mass of wet air

Last Answer : ANSWER : A

Description : At 100% relative humidity, the wet bulb temperature is A. lower than the dew point temperature B. higher than the dew point temperature C. equal to the dew point temperature D. none of the above

Last Answer : ANSWER : C

Description : . In chemical dehumidification of air (A) Both specific humidity & dry bulb temperature increases (B) Both specific humidity & dry bulb temperature decreases (C) Specific humidity decreases & dry bulb temperature increases (D) Specific humidity increases & dry bulb temperature decreases

Last Answer : (C) Specific humidity decreases & dry bulb temperature increases

Description : In sensible heating or cooling, A. work done remains constant B. dry bulb temperature or air remains constant C. both of the mentioned D. none of the mentioned

Last Answer : ANSWER : A

Description : An indication of sensible heat content in air-water vapour mixture is a) wet bulb temperature b) dew point temperature c) density of air d) dry bulb temperature

Last Answer : d) dry bulb temperature

Description : If the temperature of a piece increases suddenly, the relative humidity– (1) increases (2) decreases (3) remains constant (4) fluctuates

Last Answer : (2) decreases Explanation: Relative humidity is the ratio of the partial pressure of water vapour in a airwater mixture to the saturated vapour pressure of water at a specific temperature.

Description : If the temperature of a place increases suddenly, the relative humidity – (1) Increases (2) Decreases (3) Remains constant (4) Fluctuates

Last Answer : (2) Decreases Explanation: Relative humidity is the ratio of the partial pressure of water vapor in an airwater mixture to the saturated vapor pressure of water at a prescribed ... of the system decreases because the saturated vapor pressure of water increases with increasing temperature.

Description : On a day when the partial pressure of water vapor remains constant, what happens as the temperature rises?  a. the relative humidity increases  b. the relative humidity decreases  c. the relative humidity remains constant  d. the air would eventually become saturated

Last Answer : the relative humidity decreases

Description : If the temperature of a place increases suddenly, the relative humidity (1) Increases (2) Decreases (3) Remains constant (4) Fluctuates

Last Answer : Decreases

Description : The temperature to which a vapour gas mixture must be cooled (at varying humidity) to become saturated is called the __________ temperature. (A) Dew point (B) Wet bulb (C) Dry bulb (D) None of these

Last Answer : (D) None of these

Description : When dry bulb temperature & wet bulb temperature of moist air is the same, it means that the (A) Partial pressure of water vapour is less than the total pressure (B) Humidity is < 100% & dew ... Dew point temperature of air has not reached & air is not saturated fully (D) Air is fully saturated

Last Answer : (D) Air is fully saturated

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : High relative humidity decreases the evaporative process and as the temperature is increased, the relative humidity decreases. The comfort range for human body is the ambient temperature of 22 to 27°C with relative humidity ranging from __________ ... to 10 (B) 15 to 25 (C) 45 to 50 (D) 75 to 80

Last Answer : (C) 45 to 50

Description : When an unsaturated air-water mixture is heated at constant pressure, then (A) The partial pressure of water vapour increases (B) The specific humidity decreases (C) The relative humidity increases (D) The relative humidity decreases

Last Answer : D) The relative humidity decreases

Description : Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in ... (A) Molal (B) Relative (C) Percentage (D) None of these

Last Answer : (A) Mola

Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these

Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower

Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high

Last Answer : (B) No

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these

Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : Which of the following psychrometric processes is followed by water vapour laden unsaturated air, when it is passed through solid or liquid adsorbent? (A) Cooling and dehumidification ... (C) Dehumidification with dry bulb temperature remaining constant (D) None of these

Last Answer : (B) Heating and dehumidification at almost constant wet bulb temperature

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : In chemical dehumidification process (A) Wet bulb temperature increases (B) Dry bulb temperature remains constant (C) Dew point temperature increases (D) Dry bulb temperature increases