The wet bulb temperature is lower in dry air than in wet air at the
same temperature. A dry bulb thermometer registers a higher temperature
than a wet bulb thermometer except at __________ percent relative
humidity.
(A) 0
(B) 100
(C) 50
(D) None of these

1 Answer

Answer :

Option B

Related questions

Description : Wet-bulb temperature is: a. The temperature indicated by a thermometer whose bulb covered by a water-wetted wick and exposed to a rapidly moving stream of air b. The same as the dry-bulb ... point temperature d. Always less than the dry-bulb temperature e. Not required to find the relative humidity

Last Answer : Answer: A

Description : Dry-bulb temperature is: a. The absolute temperature corresponding to the atmospheric pressure b. The same as the wet-bulb temperature if the relative humidity is less than 100% c. Not required ... d. The temperature of the air measured with an ordinary thermometer e. The dew point temperature

Last Answer : Answer: D

Description : The dew point of moist air becomes __________ with decrease in its relative humidity. (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) More than the dry bulb temperature (D) Equal to wet bulb temperature

Last Answer : Option A

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : Unsaturated air (with dry bulb temperature and dew point being 35°C and 18°C respectively) is passed through a water spray chamber maintained at 15°C. The air will be cooled (A) And ... (C) At the same relative humidity (D) And dehumidified with decrease in wet bulb temperature

Last Answer : (D) And dehumidified with decrease in wet bulb temperature

Description : At 100% relative humidity, the wet bulb temperature is A. lower than the dew point temperature B. higher than the dew point temperature C. equal to the dew point temperature D. none of the above

Last Answer : ANSWER : C

Description : Which of the following can be calculated theoretically using steam table and Dalton's law of partial pressure; if the relative humidity and dry bulb temperature of moist air is known? (A) Dew point (B) Humidity ratio (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : During sensible heating of humid air (A) Relative humidity increases (B) Dew point remains constant (C) Dry bulb & wet bulb temperature increases (D) Both 'b' & 'c'

Last Answer : (D) Both 'b' & 'c'

Description : The dew point temperature lines on psychrometric charts are straight inclined sloping downwards to the right. When relative humidity of moist air is 100%, then (A) Wet bulb temperature=dry bulb temperature (B) ... temperature (C) Saturation temperature=dew point temperature (D) All 'a', 'b' & 'c

Last Answer : Option D

Description : Air initially at 101. 3 kPa and 40°C and with a relative humidity of 50%, is cooled at constant pressure to 30°C. The cooled air has a (A) Higher dew point (B) Higher absolute (specific) humidity (C) Higher relative humidity (D) Higher wet bulb temperature

Last Answer : (C) Higher relative humidity

Description : Relative humidity is a) the ratio of water vapour in the air compared to the total amount water vapour the air could contain at a given temperature b) equal to the dry bulb temperature divided by the wet bulb ... of dry air e) the ratio of the mass of water vapour divided by the mass of wet air

Last Answer : ANSWER : A

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : With the help of suitable diagram, explain how humidity is measured with dry and wet bulb thermometer.

Last Answer : Explanation:- 1. A psychrometer, or wet-and-dry-bulb thermometer, consists of two thermometers, one that is dry and one that is kept moist with distilled water on a sock or ... , and in the HVAC industry for proper refrigerant charging of residential and commercial air conditioning systems. 

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : A psychrometer (pron: si-'kro-me-ter) is used to measure humidity. It consists of two thermometers, one of which is wetted. The water is allowed to evaporate. Which thermometer reads the higher temperature. w) the wet one x) the dry one 

Last Answer : ANSWER: X -- THE DRY ONE 

Description : Wet bulb and dry bulb temperatures becomes identical at __________ percent saturation curve. (A) 100 (B) 50 (C) 78 (D) None of these

Last Answer : (A) 100

Description : What is the relative humidity when the dry bulb temperature is 16 and the wet bulb is 14 celcius?

Last Answer : Feel Free to Answer

Description : Sling psychrometer is used to measure A. only dry bulb temperature B. only wet bulb temperature C. dry and wet bulb temperature D. relative humidity

Last Answer : ANSWER : C

Description : A sling psychrometer is used to measure : a) only dry bulb temperature b) only wet bulb temperature c) both a & b d) relative humidity

Last Answer : c) both a & b

Description : When dry bulb temperature & wet bulb temperature of moist air is the same, it means that the (A) Partial pressure of water vapour is less than the total pressure (B) Humidity is < 100% & dew ... Dew point temperature of air has not reached & air is not saturated fully (D) Air is fully saturated

Last Answer : (D) Air is fully saturated

Description : Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in ... (A) Molal (B) Relative (C) Percentage (D) None of these

Last Answer : (A) Mola

Description : At 100% relative humidity, the dew point temperature of moist air is (A) Less than the wet bulb temperature (B) More than the wet bulb temperature (C) Equal to the wet bulb temperature (D) Equal to the ambient temperature

Last Answer : (B) More than the wet bulb temperature

Description : The temperature to which a vapour gas mixture must be cooled (at varying humidity) to become saturated is called the __________ temperature. (A) Dew point (B) Wet bulb (C) Dry bulb (D) None of these

Last Answer : (D) None of these

Description : The temperature of air recorded by thermometer when the bulb is covered by a cotton wick saturated by water is called as A. dry bulb temperature B. wet bulb temperature C. stream temperature D. psychrometric temperature

Last Answer : ANSWER : B

Description : When the difference in the temperature of the wet-bulb thermometer and dry-bulb thermometer is large, what does it indicate about the air? w) it is very dry x) it is nearly saturated y) it is very warm z) it is very cold

Last Answer : ANSWER: W -- IT IS VERY DRY

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these

Last Answer : (C) Wet bulb temperature

Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these

Last Answer : (D) None of these

Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : During sensible cooling process (A) Relative humidity decreases (B) Relative humidity increases (C) Wet bulb temperature decreases (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : High relative humidity decreases the evaporative process and as the temperature is increased, the relative humidity decreases. The comfort range for human body is the ambient temperature of 22 to 27°C with relative humidity ranging from __________ ... to 10 (B) 15 to 25 (C) 45 to 50 (D) 75 to 80

Last Answer : (C) 45 to 50

Description : For the case of flow of air past a wet bulb thermometer (air water vapour system), the approximate value of h2 /ky .Cz is around (A) 0.60 (B) 0.24 (C) 1 (D) 0.72

Last Answer : (C) 1

Description : What is the dew-point when the dry bulb temperature is 20C and the relative humidity is 17?

Last Answer : at 17% relative humidity the dew point is -5.8C at a dry bulb of20C

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : The Stevenson screen contains all of these EXCEPT: A. Wet bulb thermometer B. Maximum thermometer C. Ordinary thermometer D. Anemometer (Answer)

Last Answer : D. Anemometer (Answer)

Description : Dry bulb temperature of unsaturated air is more than its __________ temperature. (A) Dew point (B) Wet bulb (C) Both 'a' & 'b' (D) Neither 'a' nor 'b

Last Answer : (C) Both 'a' & 'b

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : Combination of Dry bulb and Wet bulb thermometer used for

Last Answer : Ans. Relative Humidity

Description : What is Psychrometer ? Explain dry bulb thermometer & wet bulb thermometer.

Last Answer : Psychrometers are instruments used for measuring relative humidity. Explanation:- A psychrometer, or wet-and-dry-bulb thermometer, consists of two thermometers, one that is dry and one ... thermometer and the difference in temperatures as shown by the wet-bulb and dry-bulb thermometers.

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : __________ temperature remains constant during adiabatic saturation process of unsaturated air. (A) Dew point (B) Dry bulb (C) Wet bulb (D) None of these

Last Answer : (C) Wet bulb

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : psychrometer does not measure the __________ temperature of moist air. (A) Dew point (B) Dry bulb (C) Wet bulb (D) None of these

Last Answer : Option A

Description : An air-water vapour mixture has a dry bulb temperature of 60°C and a dew point temperature of 40°C. The total pressure is 101.3 kPa and the vapour pressure of water at 40°C and 60°C are 7.30 kPa and 19.91 kPa respectively ... air is: (A) 0.048 (B) 0.079 (C) 0.122 (D) 0.152

Last Answer : (D) 0.152

Description : At a fixed pressure, the humidity depends upon the partial pressure of vapor in the mixture. Humidity of a vapour free gas is __________ percent. (A) 100 (B) 0 (C) 50 (D) Between 0 and 100

Last Answer : (B) 0

Description : . In chemical dehumidification of air (A) Both specific humidity & dry bulb temperature increases (B) Both specific humidity & dry bulb temperature decreases (C) Specific humidity decreases & dry bulb temperature increases (D) Specific humidity increases & dry bulb temperature decreases

Last Answer : (C) Specific humidity decreases & dry bulb temperature increases

Description : How Do You Measure Temperature In A Wet Bulb Thermometer?

Last Answer : Wet bulb temperature is measured in a wet bulb thermometer by covering the bulb with a wick and wetting it with water. It corresponds to the dew point temperature and relative humidity.

Description : Dry bulb temperature of the gas is __________ the wet bulb temperature. (A) Less than (B) More than (C) Equal to (D) None of these

Last Answer : (B) More than

Description : __________ is the temperature at which a gas-vapor mixture becomes saturated, when cooled at constant total pressure out of contact with a liquid. (A) Dew point (B) Bubble point (C) Dry bulb temperature (D) Wet bulb temperature

Last Answer : (A) Dew point