What is the difference between surge arrestor and lightning arrestor?

1 Answer

Answer :

A:Lightning Arrestor is installed outside and the effect of lightning is grounded where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Related questions

Description : Where should the lighting arrestor be placed in distribution lines?

Last Answer : A:Near distribution transformers and out going feeders of 11kv and incomming feeder of 33kv and near power transformers in sub-stations.

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : LA is installed outside and the effect of lightning is grounded, where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What Is The Difference Between Surge Arrestor And Lightning Arrestor?

Last Answer : LA is installed outside and the effect of lightning is grounded,where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : Lightning arrestor is installed outside and the effect of lightning is grounded, whereas surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What is difference between fuse and breaker?

Last Answer : A: (i) Fuse performs both detection and interruption functions. Circuit breaker performs interruption function only. The detection of fault is made by relay system. (ii) The breaking capacity of ... , replacement is required in the fuse. In case of circuit breaker, replacement is not required.

Description : What is the difference between over voltage relay and over current relay?

Last Answer : A:The current increases not only for over voltages but also for under voltage(As most of the loads are non-linear in nature). So,the over voltage protection & over current protection are completely ... , for a better protection of the system.It should have both over voltage & over current relay.

Description : What is the difference between MCB & MCCB, Where it can be used?

Last Answer : A: MCB is miniature circuit breaker which is thermal operated for overload condition and magnetically operated for short circuit protection. It is available in small current rating. MCCB is moulded case ... frequency may be inbuilt. Normally it is used where normal current is more than 100 A.

Description : What is the difference between Isolator and Circuit Breaker?

Last Answer : A: Isolator is a off load device which is used for isolating the downstream circuits from upstream circuits for the reason of any maintenance on downstream circuits. it is manually operated ... specification 1) rated current 2) short circuit breaking capacity and 3) Instantaneous tripping current.

Description : What are the various types of tariff?

Last Answer : 1. Simple tariff 2. Flat rate tariff 3. Block rate tariff 4. Two-part tariff 5. Maximum demand tariff 6. Power factor tariff 7. Three-part tariff

Description : What is tariff?

Last Answer : The rate at which electrical energy is supplied to a consumer is known as tariff. The tariff should include the following items: (i) Recovery of cost of producing electrical energy at the power ... of cost of operation and maintenance of supply (iv) A suitable profit on the capital investment.

Description : How can we reduce the effect of corona?

Last Answer : 1. By increasing conductor size: By increasing conductor size, the voltage at which corona occurs is raised and hence corona effects are considerably reduced. 2. By increasing conductor spacing: ... , the voltage at which corona occurs is raised and hence corona effects can be eliminated.

Description : What is corona?

Last Answer : The phenomenon of violet glow, hissing noise and production of ozone gas in an overhead transmission line is known as corona.

Description : What is meant by Sag?

Last Answer : The difference in level between points of supports and the lowest point on the conductor is called sag.

Description : Which type of motor is used in trains, what is the rating of supply used?

Last Answer : A:Dc series is in the trains to get high starting torque while starting of the trains and operating voltage is 1500v dc.

Description : Why we use ac system in India why not dc ?

Last Answer : A:Firstly, the output of power stations comes from a rotary turbine, which by it's nature is AC and therefore requires no power electronics to convert to DC. Secondly it is much easier to ... the sine wave current will naturally tend to zero at some point making the current easier to interrupt.

Description : Why electricity in India is in the multiples of 11 like 11kv, 22kv, 33kv ?

Last Answer : A:Transformer Induced voltage equation contains 4.44 factor. E -Induced emf per phase T -number of turns f -frequency Φ -maximum flux per pole From the equation we see that E is proportional to 4.4 and it is in turn multiple of 11.So always transmission voltage is multiple of 11

Description : When we connect the large capacitor bank in series ?

Last Answer : A :we connect large capacitor bank in series to improve the voltage power supply at the load end in balanced transmission line when there is considerable voltage drop along the balanced transmission line due ... - %6 )of the rated high terminal voltage )the large capacitor bank is used in series.

Description : What is reverse power relay?

Last Answer : A:Reverse Power flow relay are used in generating stations's protection. A generating stations is supposed to fed power to the grid and in case generating units are off,there is no generation in the ... power from grid. To stop the flow of power from grid to generator we use reverse power relay.

Description : What is derating?

Last Answer : A:The current currying of cables will change depending upon the site temperature (location of site), type of run (it will run through duct, trench, buried etc.), number of tray, depth ... of cable reduce than current currying capacity (which given to cable Catalogue) this is called derating.

Description : Define IDMT relay?

Last Answer : It is an Inverse Definite Minimum Time relay. In IDMT relay its operating is inversely proportional and also a characteristic of minimum time after which this relay operates. It is inverse in the sense; the tripping time will decrease as the magnitude of fault current increase.

Description : Explain types of Earthing.

Last Answer : A:The two types of earthing are Equipment earthing and system earthing. In Equipment earthing: body ( non conducting part) of the equipment should be earthed to safegaurd the human beings ... . This type of earthing is further classified into directly earthed, Impedance earthing, resistive earthing.

Description : What is Ferranti effect?

Last Answer : A: When receiving end voltage is greater than the sending end voltage.

Description : What is buchholz relay and the significance of it in to the transformer?

Last Answer : A:Buchholz relay is a gas based relay which is used for the protection of transformer from its internal faults. whenever any internal fault occurs in a transformer, the buchholz relay at once gives an ... then it stop its sound itself other wise it trips the circuit by its own tripping mechanism.

Description : what is power factor? whether it should be high or low? why?

Last Answer : A:Power factor is the ratio of true power to apparent power. It has to be ideally 1. If it is too low then cable over heating & equipment overloading will occur. if it is greater than 1 then load will ... : 0.95 to meet actual power, load has to draw less current(V constant),result in less losses).

Description : Explain the working principle of the circuit breaker

Last Answer : A:Circuit Breaker is one which makes or breaks the circuit.It has two contacts namely fixed contact & moving contact. Under normal condition the moving contact comes in contact with fixed contact thereby forming ... . Arc is extinguished by the Arc Quenching media like air, oil, vacuum, SF6 gas etc.

Description : Why we use Vacuum Circuit Breaker in High Transmission System and not Air Circuit Breaker?

Last Answer : A:Vacuum has high arc quenching property compare to air . The dielectric strength of vacuum is equal to 8 times than air . Hence vacuum circuit breaker is used in High voltage line and air circuit breaker is used in low voltage lines.

Description : Why syn. generators are used for the production of electricity?

Last Answer : A:synchronous machines have capability to work on different power factor. Hence syn. generators are used for the production of electricity.

Description : What will happen when power factor is leading in distribution of power?

Last Answer : A:If their is high power factor, i.e if the power factor is close to one: 1.losses in form of heat will be reduced, 2.cable becomes less bulky and easy to carry, and very cheap to afford, & 3. it also reduces over heating of transformers.

Description : what is ACSR cable and where we use it?

Last Answer : A: ACSR means Aluminium conductor steel reinforced, this conductor is used in transmission & distribution.

Description : Describe the operation carried out in Thermal power stations?

Last Answer : A:The water is boiled in the boiler with the help of coal. This generates steam. This steam is allowed to hit the turbine hence the turbine rotates. The turbine is coupled with generator. So the mechanical energy of turbine is converted to electrical energy by Generator.

Description : What is "pu" in electrical engineering?

Last Answer : PU stands for per unit and this will be used in power system single line diagram there it is like a huge electrical circuit with no of components (generators, transformers, loads) with different ratings (in ... into this basis. Those values are called as pu values. (p.u=actual value/base value).

Description : What is Electric traction?

Last Answer : A:Electric traction means using the electric power for traction system to drive the locomotives.

Description : What is meant by synchronous condenser?

Last Answer : An over excited synchronous motor running on no load is known as synchronous condenser. It is used to improve the power factor of the system.

Description : What is the type of Lightning Arrestor?

Last Answer : Station type, heavy duty, gap less zinc oxide.  

Description : What is the purpose of lightning arrestor? 

Last Answer : Due to lightning and switching surges high voltages are induced in the lines. If equipment's. Connected is subjected to this high voltage the insulation will fail. In order to avoid the failure of ... current to the earth. (It will divert the over voltages to earth and protect the substation)  

Description : For a fault in switchyard lightning arrestor, what protection will act?

Last Answer : Bus bar differential protection.  

Description : Give the details of switchyard 220 kV CB, Isolator, CT, CVT and lightning arrestor.  

Last Answer : 220 kV SF6 Circuit Breaker 1. Make - ABB 2. Air pressure blocking a. Close Block - 17.3 bar. b. Open block - 16.7 bar. c. Auto reclose block - 19 bar. 3. SF6 pressure block a. Alarm - 5. ... , storage and erection. Rated voltage : 216 kV rms. Operating voltage : 184 kV rms. 

Description : What is the type of lightning arrestor for GT? 

Last Answer : Zn O (zinc oxide) types.  

Description : In 220 kV switchyard why lightning arrestor should be properly grounded?

Last Answer : a. During lightning, surges should be discharged to ground, otherwise it will puncture the equipment insulation and it is possible only when lightning arrestor is grounded properly.  b. In order to make it effective ... kV. Soil resistivity a should be minimum and may be it is 3.5 ohm per meter.  

Description : Write types of lightning arrestor.

Last Answer : a. Horn gap lightning arrestor. b. Oxide film lightning arrestor. c. Pellet lightning arrestor. d. Thyrite lightning arrestor.

Description : What is the difference between the lightning arrester and surge absorber?

Last Answer : Lightning arrester limits the duration and amplitude of the follow current while a surge absorber reduces the steepness of the wave front for a particular surge

Description : How does a lightning arrestor work?

Last Answer : ANSWER I: Lightning, is a form of visible discharge of electricity between rain clouds or between a rain cloud and the earth. The electric discharge is seen in the form of a brilliant arc, ... a cone of protection, which has a ground radius approximately, equal to its height above the ground.

Description : What is meant by Lightning arrester or surge diverter?

Last Answer : A Surge Diverter is a device that is connected between line and earth, i.e, in parallel with the equipment under protection at the substation. It limits the duration and amplitude of the follow current

Description : Which of the following devices will receive voltage surge first travelling on the transmission line ? (a) Lightning arresters (b) Relays (c) Step-down transformer (d) Switchgear

Last Answer : (a) Lightning arresters

Description : Which of the following statements is incorrect? (a) Station batteries are used to operate relay only (b) The lightning arresters are basically surge diverters (c) An impedance relay has maximum fault current when fault occurs near the relay (d) A high speed relay has an operation of 1 to 2 cycles

Last Answer : (a) Station batteries are used to operate relay only

Description : Where should the lighting arrestor is placed in distribution lines?

Last Answer : Near distribution transformers and out going feeders of 11kv and incoming feeder of 33kv and near power transformers in sub-stations.

Description : What is the difference between flash back arrestor and check valve? 

Last Answer : A check valve allows flow in one direction only. This prevents oxygen reaching acetylene cylinder and acetylene reaching oxygen cylinder in the event of blockage in the torch or line or pressure variations.

Description : When insulation failure produces a low resistance current path between two conductors, the resulting condition is known as ____________. A. an open B. a short circuit C. a ground D. a surge

Last Answer : Answer: B

Description : What is the function of the interpoles installed in DC motors? A. To provide greater torque by strengthening the main field. B. To provide sparkless commutation without having to shift the brushes. C. To limit the production of counter-electromotive force. D. To limit the starting surge current.

Last Answer : Answer: B

Description : Fuses placed in series with a thermal trip-type circuit breaker are used for _____________. A. time-delay protection B. short-circuit protection C. short duration surge protection D. sustained overload protection

Last Answer : Answer: B