What is reverse power relay?

1 Answer

Answer :

A:Reverse Power flow relay are used in generating stations's protection. A generating stations is supposed to fed power to the grid and in case generating units are off,there is no generation in the plant then plant may take power from grid. To stop the flow of power from grid to generator we use reverse power relay.

Related questions

Description : What is the difference between over voltage relay and over current relay?

Last Answer : A:The current increases not only for over voltages but also for under voltage(As most of the loads are non-linear in nature). So,the over voltage protection & over current protection are completely ... , for a better protection of the system.It should have both over voltage & over current relay.

Description : Define IDMT relay?

Last Answer : It is an Inverse Definite Minimum Time relay. In IDMT relay its operating is inversely proportional and also a characteristic of minimum time after which this relay operates. It is inverse in the sense; the tripping time will decrease as the magnitude of fault current increase.

Description : What is buchholz relay and the significance of it in to the transformer?

Last Answer : A:Buchholz relay is a gas based relay which is used for the protection of transformer from its internal faults. whenever any internal fault occurs in a transformer, the buchholz relay at once gives an ... then it stop its sound itself other wise it trips the circuit by its own tripping mechanism.

Description : what is power factor? whether it should be high or low? why?

Last Answer : A:Power factor is the ratio of true power to apparent power. It has to be ideally 1. If it is too low then cable over heating & equipment overloading will occur. if it is greater than 1 then load will ... : 0.95 to meet actual power, load has to draw less current(V constant),result in less losses).

Description : What will happen when power factor is leading in distribution of power?

Last Answer : A:If their is high power factor, i.e if the power factor is close to one: 1.losses in form of heat will be reduced, 2.cable becomes less bulky and easy to carry, and very cheap to afford, & 3. it also reduces over heating of transformers.

Description : Describe the operation carried out in Thermal power stations?

Last Answer : A:The water is boiled in the boiler with the help of coal. This generates steam. This steam is allowed to hit the turbine hence the turbine rotates. The turbine is coupled with generator. So the mechanical energy of turbine is converted to electrical energy by Generator.

Description : What are the various types of tariff?

Last Answer : 1. Simple tariff 2. Flat rate tariff 3. Block rate tariff 4. Two-part tariff 5. Maximum demand tariff 6. Power factor tariff 7. Three-part tariff

Description : What is tariff?

Last Answer : The rate at which electrical energy is supplied to a consumer is known as tariff. The tariff should include the following items: (i) Recovery of cost of producing electrical energy at the power ... of cost of operation and maintenance of supply (iv) A suitable profit on the capital investment.

Description : How can we reduce the effect of corona?

Last Answer : 1. By increasing conductor size: By increasing conductor size, the voltage at which corona occurs is raised and hence corona effects are considerably reduced. 2. By increasing conductor spacing: ... , the voltage at which corona occurs is raised and hence corona effects can be eliminated.

Description : What is corona?

Last Answer : The phenomenon of violet glow, hissing noise and production of ozone gas in an overhead transmission line is known as corona.

Description : What is meant by Sag?

Last Answer : The difference in level between points of supports and the lowest point on the conductor is called sag.

Description : What is difference between fuse and breaker?

Last Answer : A: (i) Fuse performs both detection and interruption functions. Circuit breaker performs interruption function only. The detection of fault is made by relay system. (ii) The breaking capacity of ... , replacement is required in the fuse. In case of circuit breaker, replacement is not required.

Description : Which type of motor is used in trains, what is the rating of supply used?

Last Answer : A:Dc series is in the trains to get high starting torque while starting of the trains and operating voltage is 1500v dc.

Description : Why we use ac system in India why not dc ?

Last Answer : A:Firstly, the output of power stations comes from a rotary turbine, which by it's nature is AC and therefore requires no power electronics to convert to DC. Secondly it is much easier to ... the sine wave current will naturally tend to zero at some point making the current easier to interrupt.

Description : Why electricity in India is in the multiples of 11 like 11kv, 22kv, 33kv ?

Last Answer : A:Transformer Induced voltage equation contains 4.44 factor. E -Induced emf per phase T -number of turns f -frequency Φ -maximum flux per pole From the equation we see that E is proportional to 4.4 and it is in turn multiple of 11.So always transmission voltage is multiple of 11

Description : When we connect the large capacitor bank in series ?

Last Answer : A :we connect large capacitor bank in series to improve the voltage power supply at the load end in balanced transmission line when there is considerable voltage drop along the balanced transmission line due ... - %6 )of the rated high terminal voltage )the large capacitor bank is used in series.

Description : What is derating?

Last Answer : A:The current currying of cables will change depending upon the site temperature (location of site), type of run (it will run through duct, trench, buried etc.), number of tray, depth ... of cable reduce than current currying capacity (which given to cable Catalogue) this is called derating.

Description : Where should the lighting arrestor be placed in distribution lines?

Last Answer : A:Near distribution transformers and out going feeders of 11kv and incomming feeder of 33kv and near power transformers in sub-stations.

Description : What is the difference between MCB & MCCB, Where it can be used?

Last Answer : A: MCB is miniature circuit breaker which is thermal operated for overload condition and magnetically operated for short circuit protection. It is available in small current rating. MCCB is moulded case ... frequency may be inbuilt. Normally it is used where normal current is more than 100 A.

Description : Explain types of Earthing.

Last Answer : A:The two types of earthing are Equipment earthing and system earthing. In Equipment earthing: body ( non conducting part) of the equipment should be earthed to safegaurd the human beings ... . This type of earthing is further classified into directly earthed, Impedance earthing, resistive earthing.

Description : What is Ferranti effect?

Last Answer : A: When receiving end voltage is greater than the sending end voltage.

Description : What is the difference between Isolator and Circuit Breaker?

Last Answer : A: Isolator is a off load device which is used for isolating the downstream circuits from upstream circuits for the reason of any maintenance on downstream circuits. it is manually operated ... specification 1) rated current 2) short circuit breaking capacity and 3) Instantaneous tripping current.

Description : Explain the working principle of the circuit breaker

Last Answer : A:Circuit Breaker is one which makes or breaks the circuit.It has two contacts namely fixed contact & moving contact. Under normal condition the moving contact comes in contact with fixed contact thereby forming ... . Arc is extinguished by the Arc Quenching media like air, oil, vacuum, SF6 gas etc.

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : A:Lightning Arrestor is installed outside and the effect of lightning is grounded where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : Why we use Vacuum Circuit Breaker in High Transmission System and not Air Circuit Breaker?

Last Answer : A:Vacuum has high arc quenching property compare to air . The dielectric strength of vacuum is equal to 8 times than air . Hence vacuum circuit breaker is used in High voltage line and air circuit breaker is used in low voltage lines.

Description : Why syn. generators are used for the production of electricity?

Last Answer : A:synchronous machines have capability to work on different power factor. Hence syn. generators are used for the production of electricity.

Description : what is ACSR cable and where we use it?

Last Answer : A: ACSR means Aluminium conductor steel reinforced, this conductor is used in transmission & distribution.

Description : What is "pu" in electrical engineering?

Last Answer : PU stands for per unit and this will be used in power system single line diagram there it is like a huge electrical circuit with no of components (generators, transformers, loads) with different ratings (in ... into this basis. Those values are called as pu values. (p.u=actual value/base value).

Description : What is Electric traction?

Last Answer : A:Electric traction means using the electric power for traction system to drive the locomotives.

Description : What is meant by synchronous condenser?

Last Answer : An over excited synchronous motor running on no load is known as synchronous condenser. It is used to improve the power factor of the system.

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed

Last Answer : Answer: D

Description : An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the ... C. the alternator was operating out of synchronism D. flashover at the alternator collector rings

Last Answer : Answer: C

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.

Last Answer : Answer: D

Description : The operating torque of the upper induction disc-type element, or timer element, of an AC reverse power relay is obtained from ____________. A. the main bus B. a separate battery source C. line voltage D. electromagnets

Last Answer : Answer: D

Description : The purpose of the reverse power relay, provided on a ship's service alternator panel, is to trip the circuit in the event of ______________. A. main circuit overload B. high power transfer C. generator overspeeding D. alternator motorization

Last Answer : Answer: D

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : The timer element of a reverse power relay cannot be energized unless _____________. A. the power flow is the same as the tripping direction B. the power flow is the opposite to the tripping direction C. the movement of the disk is damped by a permanent magnet D. one generator is motorized

Last Answer : Answer: A

Description : Equal power factors on paralleled AC generators are maintained by an automatic _____________. A. voltage regulator B. reverse power relay C. reverse current relay D. governor control switch

Last Answer : Answer: A

Description : The timer element of a reverse power relay cannot be energized unless _____________. A. one generator is fully motorized B. the movement of the disk is damped by a permanent magnet C. the power flow is the same as the tripping direction D. the power flow is the opposite to the tripping direction

Last Answer : Answer: C

Description : The timer element found in a reverse power relay obtains its operating torque via _____________. A. line voltage B. the main bus C. electromagnets D. a separate battery source

Last Answer : Answer: C

Description : A generator is prevented from becoming motorized by the use of a/an _____________. A. overspeed trip B. reverse power relay C. back pressure trip D. governor controls

Last Answer : Answer: B

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : What is reverse power relay?

Last Answer : Reverse Power flow relay are used to stop the flow of power from grid to station generator when the generating units are off.

Description : Why low forward power relay used in parallel to reverse power relay?

Last Answer : A small steam leak through CIES valves will keep the machine floating on to grid at low power. So even if turbine trip, relay picks up, there is no trip actually. So low forward power relay (0.54%) used to detect the condition. 

Description : What is reverse power relay?

Last Answer : Reverse Power flow relay are used in generating stations' protection.  A generating station is supposed to feed power to the grid and in case generating units are off, there is no generation in the ... power from grid. To stop the flow of power from grid to generator we use reverse power relay.

Description : A diesel driven emergency generator is prevented from being paralleled with the ship's service generators by __________. A. an electrical interlock system B. an automatic paralleling trip switch C. the synchronizing oscilloscope D. the reverse current relay

Last Answer : Answer: A

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : what is reverse power relay?

Last Answer : Thereverse powerrelay is a directional protective relay that prevents power from flowing in the reverse direction. Read our article going back ... it all to be up to date. And if you do, read it anyway just to check if youreallydo!