What is difference between fuse and breaker?

1 Answer

Answer :

A: (i)  Fuse performs both detection and interruption  functions. Circuit breaker performs interruption function only. The detection of fault is made by relay system. (ii) The breaking capacity of fuse is very small compare to that of circuit breaker. (iii) The operating time of the fuse is smaller than operating time of CB. (iv) After every operation, replacement is required in the fuse. In case of circuit breaker, replacement is not required.

Related questions

Description : What is the difference between Isolator and Circuit Breaker?

Last Answer : A: Isolator is a off load device which is used for isolating the downstream circuits from upstream circuits for the reason of any maintenance on downstream circuits. it is manually operated ... specification 1) rated current 2) short circuit breaking capacity and 3) Instantaneous tripping current.

Description : Explain the working principle of the circuit breaker

Last Answer : A:Circuit Breaker is one which makes or breaks the circuit.It has two contacts namely fixed contact & moving contact. Under normal condition the moving contact comes in contact with fixed contact thereby forming ... . Arc is extinguished by the Arc Quenching media like air, oil, vacuum, SF6 gas etc.

Description : Why we use Vacuum Circuit Breaker in High Transmission System and not Air Circuit Breaker?

Last Answer : A:Vacuum has high arc quenching property compare to air . The dielectric strength of vacuum is equal to 8 times than air . Hence vacuum circuit breaker is used in High voltage line and air circuit breaker is used in low voltage lines.

Description : What is the difference between over voltage relay and over current relay?

Last Answer : A:The current increases not only for over voltages but also for under voltage(As most of the loads are non-linear in nature). So,the over voltage protection & over current protection are completely ... , for a better protection of the system.It should have both over voltage & over current relay.

Description : What is the difference between MCB & MCCB, Where it can be used?

Last Answer : A: MCB is miniature circuit breaker which is thermal operated for overload condition and magnetically operated for short circuit protection. It is available in small current rating. MCCB is moulded case ... frequency may be inbuilt. Normally it is used where normal current is more than 100 A.

Description : What is the difference between surge arrestor and lightning arrestor?

Last Answer : A:Lightning Arrestor is installed outside and the effect of lightning is grounded where as surge arrestor installed inside panels comprising of resistors which consumes the energy and nullify the effect of surge.

Description : What are the various types of tariff?

Last Answer : 1. Simple tariff 2. Flat rate tariff 3. Block rate tariff 4. Two-part tariff 5. Maximum demand tariff 6. Power factor tariff 7. Three-part tariff

Description : What is tariff?

Last Answer : The rate at which electrical energy is supplied to a consumer is known as tariff. The tariff should include the following items: (i) Recovery of cost of producing electrical energy at the power ... of cost of operation and maintenance of supply (iv) A suitable profit on the capital investment.

Description : How can we reduce the effect of corona?

Last Answer : 1. By increasing conductor size: By increasing conductor size, the voltage at which corona occurs is raised and hence corona effects are considerably reduced. 2. By increasing conductor spacing: ... , the voltage at which corona occurs is raised and hence corona effects can be eliminated.

Description : What is corona?

Last Answer : The phenomenon of violet glow, hissing noise and production of ozone gas in an overhead transmission line is known as corona.

Description : What is meant by Sag?

Last Answer : The difference in level between points of supports and the lowest point on the conductor is called sag.

Description : Which type of motor is used in trains, what is the rating of supply used?

Last Answer : A:Dc series is in the trains to get high starting torque while starting of the trains and operating voltage is 1500v dc.

Description : Why we use ac system in India why not dc ?

Last Answer : A:Firstly, the output of power stations comes from a rotary turbine, which by it's nature is AC and therefore requires no power electronics to convert to DC. Secondly it is much easier to ... the sine wave current will naturally tend to zero at some point making the current easier to interrupt.

Description : Why electricity in India is in the multiples of 11 like 11kv, 22kv, 33kv ?

Last Answer : A:Transformer Induced voltage equation contains 4.44 factor. E -Induced emf per phase T -number of turns f -frequency Φ -maximum flux per pole From the equation we see that E is proportional to 4.4 and it is in turn multiple of 11.So always transmission voltage is multiple of 11

Description : When we connect the large capacitor bank in series ?

Last Answer : A :we connect large capacitor bank in series to improve the voltage power supply at the load end in balanced transmission line when there is considerable voltage drop along the balanced transmission line due ... - %6 )of the rated high terminal voltage )the large capacitor bank is used in series.

Description : What is reverse power relay?

Last Answer : A:Reverse Power flow relay are used in generating stations's protection. A generating stations is supposed to fed power to the grid and in case generating units are off,there is no generation in the ... power from grid. To stop the flow of power from grid to generator we use reverse power relay.

Description : What is derating?

Last Answer : A:The current currying of cables will change depending upon the site temperature (location of site), type of run (it will run through duct, trench, buried etc.), number of tray, depth ... of cable reduce than current currying capacity (which given to cable Catalogue) this is called derating.

Description : Define IDMT relay?

Last Answer : It is an Inverse Definite Minimum Time relay. In IDMT relay its operating is inversely proportional and also a characteristic of minimum time after which this relay operates. It is inverse in the sense; the tripping time will decrease as the magnitude of fault current increase.

Description : Where should the lighting arrestor be placed in distribution lines?

Last Answer : A:Near distribution transformers and out going feeders of 11kv and incomming feeder of 33kv and near power transformers in sub-stations.

Description : Explain types of Earthing.

Last Answer : A:The two types of earthing are Equipment earthing and system earthing. In Equipment earthing: body ( non conducting part) of the equipment should be earthed to safegaurd the human beings ... . This type of earthing is further classified into directly earthed, Impedance earthing, resistive earthing.

Description : What is Ferranti effect?

Last Answer : A: When receiving end voltage is greater than the sending end voltage.

Description : What is buchholz relay and the significance of it in to the transformer?

Last Answer : A:Buchholz relay is a gas based relay which is used for the protection of transformer from its internal faults. whenever any internal fault occurs in a transformer, the buchholz relay at once gives an ... then it stop its sound itself other wise it trips the circuit by its own tripping mechanism.

Description : what is power factor? whether it should be high or low? why?

Last Answer : A:Power factor is the ratio of true power to apparent power. It has to be ideally 1. If it is too low then cable over heating & equipment overloading will occur. if it is greater than 1 then load will ... : 0.95 to meet actual power, load has to draw less current(V constant),result in less losses).

Description : Why syn. generators are used for the production of electricity?

Last Answer : A:synchronous machines have capability to work on different power factor. Hence syn. generators are used for the production of electricity.

Description : What will happen when power factor is leading in distribution of power?

Last Answer : A:If their is high power factor, i.e if the power factor is close to one: 1.losses in form of heat will be reduced, 2.cable becomes less bulky and easy to carry, and very cheap to afford, & 3. it also reduces over heating of transformers.

Description : what is ACSR cable and where we use it?

Last Answer : A: ACSR means Aluminium conductor steel reinforced, this conductor is used in transmission & distribution.

Description : Describe the operation carried out in Thermal power stations?

Last Answer : A:The water is boiled in the boiler with the help of coal. This generates steam. This steam is allowed to hit the turbine hence the turbine rotates. The turbine is coupled with generator. So the mechanical energy of turbine is converted to electrical energy by Generator.

Description : What is "pu" in electrical engineering?

Last Answer : PU stands for per unit and this will be used in power system single line diagram there it is like a huge electrical circuit with no of components (generators, transformers, loads) with different ratings (in ... into this basis. Those values are called as pu values. (p.u=actual value/base value).

Description : What is Electric traction?

Last Answer : A:Electric traction means using the electric power for traction system to drive the locomotives.

Description : What is meant by synchronous condenser?

Last Answer : An over excited synchronous motor running on no load is known as synchronous condenser. It is used to improve the power factor of the system.

Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater

Last Answer : Answer: D

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : If an electric motor fails to start, you should FIRST check the _____________. A. phase sequence B. ampere load C. fuse or circuit breaker D. line frequency

Last Answer : Answer: C

Description : When an AC or a DC motor fails to start, the FIRST step in troubleshooting should be to check the ____________. A. motor windings for obvious opens B. motor controller leads for continuity C. fuse or circuit breaker D. motor controller leads for grounds

Last Answer : Answer: C

Description : A circuit breaker differs from a fuse in that a circuit breaker _____________. A. melts and must be replaced B. is enclosed in a tube of insulating material with metal ferrules at each end C. gives no visual indication of having opened the circuit D. trips to break the circuit and may be reset

Last Answer : Answer: D

Description : A circuit breaker and a fuse have a basic similarity in that they both _____________. A. can be reset to energize the circuit B. should open the circuit when overloaded C. will burn out when an over current flow develops D. all of the above

Last Answer : Answer: B

Description : Differentiate between a fuse and a circuit breaker.

Last Answer : Fuse is a low current interrupting device. It is a copper or an aluminium wire. Circuit breaker is a high current interrupting device and it act as a switch under normal operating conditions.

Description : What is the difference between a fuse and a circuit breaker ?

Last Answer : Fuse : It is a type of soft metal wire which, when more than the required current flows through the wire, burns it, disconnects the electrical circuit from the source and protects the valuable ... or fault in the power supply line . This breaks the static contact and protects it from accidents.

Description : Why will too many electrical devices operating at one time after blow a fuse or trip a circuit breaker?

Last Answer : The load exceeds the limit of the breaker or fuse. For example a20 amp breaker on a 120 volt circuit will handle 2400 watts. Exceedthat wattage and the breaker will trip or the fuse will blow.

Description : Which of the following is the least expensive protection for overcurrent is low voltage system ? (a) Rewireable fuse (b) Isolator (c) Oil circuit breaker (d) Air break circuit breaker (e) None of the above

Last Answer : (a) Rewireable fuse

Description : What is the difference between Isolator and Circuit Breaker?

Last Answer : Isolator is an off load device which is used for isolating the downstream circuits from upstream circuits for the reason of any maintenance on downstream circuits. It is manually operated and does ... is rated current and 2 is short circuit breaking capacity and 3 is instantaneous tripping current.

Description : What is the difference between circuit breaker and isolator?

Last Answer : Isolator is a disconnecting switch which is not having the making and breaking capacity. Bus coupler - 2000A Feeders - 1600 A

Description : What is the difference between a contactor and a breaker?

Last Answer : Contactor is not designed to open on short circuit condition (fuse will take care of this situation). Breaker is having complicated mechanism for closing and tripping. 

Description : Which one of the following applications software’s is used to obtain an accurate root locus for? a) LISP b) MATLAB c) dBase d) Oracle Ans: B 6.Lenz devised a rule to find out direction of a)current induced in a circuit b)electromagneticdifference c)potential difference d)flow of power in fuse

Last Answer : Ans: A

Description : Which of the following busbar arrangement is generally employed in distribution system: a) One-and-half breaker arrangement b) Main and transfer arrangement c) Ring main distribution system d) Single busbar arrangement system

Last Answer : Ans: C

Description : Coast Guard Regulations (46 CFR) require each switchboard to have ___________. A. non-conductive deck covering at the frount B. non-conductive deck coverings at the rear C. a name plate for each circuit breaker D. all the above

Last Answer : Answer: D

Description : Before any work on electrical or electronic equipment is performed, which of the following precautions should be carried out? A. De-energize the applicable switchboard bus. B. Bypass the interlocks. C. ... supply circuit breaker in the open position. D. Station a man at the circuit supply switch.

Last Answer : Answer: C

Description : Which of the synchroscope illustrations depicts the appropriate direction of rotation and position for closing the circuit breaker when paralleling AC generators? EL-0053 A. A B. B C. C D. D

Last Answer : Answer: D