Description : A molded-case breaker provides protection against short circuits by using a/an ____________. A. shading coil B. arc quencher C. electromagnet D. holding coil
Last Answer : Answer: C
Description : Protection against sustained overloads occurring in molded-case circuit breakers is provided by a/an __________. A. overvoltage release B. thermal acting trip C. thermal overload relay D. current overload relay
Last Answer : Answer: B
Description : How will a molded-case circuit breaker react after it has tripped, as a result of an overloaded circuit? A. The breaker will trip again if immediately reset. B. The breaker handle will lock in ... down. D. The breaker handle cannot be moved to the OFF position until the thermal element cools down.
Last Answer : Answer: A
Description : When the operating handle of a molded case circuit breaker is in the mid-position, it indicates the circuit breaker is _____________. A. in the 'opened' position B. in the 'closed' position C. tripped D. reset
Description : When the operating handle of a molded-case circuit breaker is in the mid-position, the circuit breaker is indicated as being ____________. A. in the 'closed' position B. in the 'opened' position C. tripped D. reset
Description : When the operating handle of a molded-case circuit breaker is in the mid-position, this indicates that the circuit breaker is _____________. A. on B. off C. reset D. tripped
Last Answer : Answer: D
Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage
Description : Electric circuits are protected against overloads and short circuits by means of a/an ______________. A. circuit breaker B. amplifier C. diode D. capacitor
Description : The arc resulting from the tripping of a circuit breaker is prevented from damaging the contacts by _____________. A. designing the contacts to open slowly B. directing the arc into an ... an inverse timed thermal trip for short circuit currents D. instantaneous magnetic trip for overload currents
Description : Electrical circuits are protected against overheating by means of a/an ______________. A. circuit breaker B. amplifier C. diode D. capacitor
Description : You can determine if a circuit breaker has tripped by ________________. A. examining the position of the handle B. checking for which of the breakers is warm C. looking for a burned-out link D. all of the above
Description : Fuses placed in series with a thermal trip-type circuit breaker are used for _____________. A. time-delay protection B. short-circuit protection C. short duration surge protection D. sustained overload protection
Description : A loud buzzing noise in an AC controller is probably caused by _____________. A. poor contact with the overload relay B. an incorrectly sized heater C. a broken shading coil D. abnormal starting current
Description : If the contacts of a motor starter or controller fail to drop out when the 'stop' button is depressed the ____________. A. contacts are carrying excessive current B. contacts have become welded together C. shading coil is broken D. shading coil is loose
Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload
Description : A shading coil used in an AC magnetic controller, functions to _____________. A. reduce vibration and noise in the contactor B. prevent flux buildup in the operating coil C. eliminate arcing when the contacts close D. energize the operating coil and 'pull in' the contacts
Description : Where a thermal-acting breaker is required to be used in an area of unusually high, low, or constantly fluctuating temperatures, an ambient compensating element must be used. This element consists of ... arm B. conical spring on the contact arm C. second bimetal element D. second electromagnet
Description : Motor controllers are seldom troubled by grounds because ________________. A. cabinet heaters always keep internal components dry B. special insulation is used on wire for vital circuits C. ... on controller panels greatly reduce vibration D. contactors and relays are mounted on nonconducting panels
Description : A circuit breaker and a fuse have a basic similarity in that they both _____________. A. can be reset to energize the circuit B. should open the circuit when overloaded C. will burn out when an over current flow develops D. all of the above
Description : The schematic diagram shown in the illustration uses symbol 'A' to represent a/an _________. EL-0011 A. non-renewable fuse link B. circuit breaker coil C. overload relay coil D. thermal overload heater
Description : The purpose of a main switchboard circuit breaker's reverse-power trip is to _____________. A. prevent main circuit overload B. protect the circuit breaker blowout coil C. prevent alternator motorization D. prevent low voltage tripout
Description : Component F in the illustrated device is for _________. EL-0033 A. short circut protection B. latching the trip unit closed after resetting the breaker C. overload protection D. providing a flexible connection between the input terminal G and the tripping unit E
Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above
Last Answer : (b) internal short-circuits
Description : H.R.C. fuses provide best protection against (a) overload (b) reverse current (c) open-circuits (d) short-circuits
Last Answer : (d) short-circuits
Description : Compressed air should not be used to clean motor controller equipment because ________________. A. it may force metallic particles into coil insulation B. the surrounding area may need additional cleaning C. the air blast dries out insulation quickly D. a mask and respirator would be required
Description : If many turns of an alternating current coil for a contactor become short circuited, the coil _____________. A. will continue to operate B. will probably burn out immediately C. will operate on reduced current D. temperature will drop
Description : If many turns of an alternating current coil for a contactor become short circuited, the coil _____________. A. temperature will drop B. will probably burn out immediately C. will continue to operate D. will operate on reduced current
Description : Where automatic restart does not present a hazard after a power failure, Coast Guard Regulations (46 CFR) require motor controllers for auxiliaries vital to the propelling equipment to be provided ... overload protection B. low voltage protection C. low voltage release D. reverse current protection
Description : Magnetic flux linked with a coil can be changed by using an: a. Permanent magnet b.Bar magnet c. Electromagnet d. Horseshoe magnet
Last Answer : b.Bar magne
Description : In the illustration, the purpose of part B is to _________. EL-0033 A. increase resistance in series with the contacts as they close to prevent arcing B. create a magnetic field in the steel ... event of an overload D. provide ventilation to the contact when the breaker is close to rated capacity
Description : How arc is quenched in Generator Field Breaker?
Last Answer : By magnetic blow out coils, arc is elongated very fastly, so resistance of arc increases, soon becoming unstable and quenched by arc chutes.
Last Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.
Description : The main difference between a motor control circuit containing low voltage protection and low voltage release is that the latter contains _____________. A. a magnetic operating coil B. normally open line contacts C. thermal-overload protection D. a momentary-contact start button
Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.
Description : Two paralleled alternators are operating near rated load. If one trips out mechanically, which of the listed actions should be taken FIRST? A. Restart the tripped machine immediately. B. Strip the board ... circuits. C. Start the emergency generator. D. Transfer all vital loads to the emergency bus.
Description : Electric strip heaters are used in motor controllers to _____________. A. prevent freezing of movable contacts B. keep the components at their design ambient temperature C. prevent condensation of moisture D. minimize resistance in internal circuits
Description : Arc in a circuit breaker is interrupted at (a) zero current (b) maximum current (c) minimum voltage (d) maximum voltage
Last Answer : (a) zero current
Description : The arc voltage produced in A.C. circuit breaker is always (a) in phase with the arc current (b) lagging the arc current by 90" (c) leading the arc current by 90° (d) none of the above
Last Answer : (a) in phase with the arc current
Description : In a circuit breaker the basic problem is to (a) maintain the arc (b) extinguish the arc (c) transmit large power (d) emit the ionizing electrons
Last Answer : (c) transmit large power
Description : The voltage appearing across the contacts after opening of the circuit breaker is called______voltage. (a) recovery (b) surge (c) operating (d) arc (e) none of the above
Last Answer : (a) recovery
Description : Which of the following medium is employed for extinction of arc in air circuit breaker ? (a) Water (b) Oil (c) Air (d) SF6
Last Answer : (c) Air
Description : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6
Last Answer : Which of the following medium is employed for extinction of arc in air circuit breaker ?(a) Water (b) Oil(c) Air (d) SF6
Description : The arc temperature in Oil Circuit Breaker may reach up to_______. (A) 5,000° K (B) 8,000° K (C) 10,000° K (D) None of the above
Last Answer : The arc temperature in Oil Circuit Breaker may reach up to 5,000° K
Description : The arc voltage in a circuit breaker is :
Last Answer : The arc voltage in a circuit breaker is : in phase with the arc current
Description : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above
Last Answer : Which of the following is used in a circuit breaker as the medium in which the arc forms? A) Insulating gas B) Insulating oil C) Vacuum D) All the above
Last Answer : Arc in a circuit breaker is interrupted at zero current.
Last Answer : The arc voltage produced in A.C. circuit breaker is always in phase with the arc current.
Description : Circuit breakers are essentially (a) current carrying contacts called electrodes (b) arc extinguishers (c) circuits to break the system (d) transformers to isolate the two systems (e) any of the above
Last Answer : (a) current carrying contacts called electrodes
Description : When working on electrical circuits containing large capacitors, in addition to deenergizing the circuit, which of the listed precautions should also be taken? A. Keep all radio equipment ... capacitor insulation resistance. C. Ground the capacitor terminals. D. Check capacitor circuit polarity.
Description : When a fluorescent lamp has reached the end of its useful life, it should be replaced immediately, or the resultant flashing may _____________. A. blow the lamp's circuit breaker B. explode, ... fly in all directions C. short circuit the ballast transformer D. damage the starter and the ballast