The need for insulation cleaning may be determined by _____. A. visual inspection for dirt accumulation B. high megger readings C. low operating temperature D. the time period since the last cleaning

1 Answer

Answer :

Answer: A

Related questions

Description : Which of the listed conditions could indicate the need for cleaning electrical insulation? A. Low ambient temperature B. Low operating temperature C. High dielectric strength D. Low megger readings

Last Answer : Answer: D

Description : Which of the conditions listed will indicate the need to clean the insulation on the windings of an electric motor? A. Higher than normal operating temperature. B. Excessive vibration at normal speed. C. Sparking at the brushes. D. High megger readings.

Last Answer : Answer: A

Description : Electrical failures in motors are caused by the breakdown of insulation, which may be caused by _____________. A. penetration of moisture B. accumulation of dirt C. overheating D. all of the above

Last Answer : Answer: D

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Description : Routine maintenance of dry-type transformers should include ______________. A. preventing the entrance of water from broken pipe lines steam lines B. keeping protective surfaces and insulating bushings free of ... debris C. periodic testing of insulation resistance with a megger D. all of the above

Last Answer : Answer: D

Description : Electrical machinery insulation will break down more rapidly due to _________________. A. low loading of motors and generators B. frequent megger testing C. high temperatures and vibration D. high operating frequencies

Last Answer : Answer: C

Description : The electrician reports to you that he has obtained low (but above 1 megohm) megger readings on the windings of a deck winch motor. Upon checking the records of that motor, you find the readings have ... yea A. motor be replaced B. windings be dried C. windings be cleaned D. readings are acceptable

Last Answer : Answer: D

Description : Routine maintenance of a ship's service alternator should include ______________. A. changing the pedestal bearing insulation yearly B. megger testing of all rectifying diodes C. lubricating excitation slip rings D. periodic cleaning of the air filters or screens

Last Answer : Answer: D

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : Aboard ship, a grounded field coil in an AC motor can be determined by using a _________________. A. portable growler B. galvanometer C. visual inspection D. megohmmeter

Last Answer : Answer: D

Description : Cleaning of electrical insulation should be _____________. A. done every six months B. accomplished every 12 months C. determined by need and not the calendar D. performed whenever the electrician is not otherwise busy

Last Answer : Answer: C

Description : As shown in the illustration, what maintenance would be required of the circuit components? EL-0058 A. Change out both 'C' units monthly. B. Clean the glass surrounding 'E1' & 'E2' as needed. C. File ... upper end of 'G' every six months. D. Take megger readings on 'E1' & 'E2' windings quarterly.

Last Answer : Answer: B

Description : As a general rule, the first troubleshooting action to be taken in checking faulty electric control devices is to _____________. A. draw a one line diagram of the circuitry B. test all fuses and measure the line voltage C. take megger readings D. insulate the apparatus from ground

Last Answer : Answer: B

Description : Routine A.C. motor maintenance should include periodic ______________. A. thermometer readings at normal loads to detect abnormal temperature rises B. inspection of the motor's internals for loose rotor bars ... C. bearing replacement each year using sealed units if available D. all of the above

Last Answer : Answer: A

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : In addition to testing the calibration of a circuit breaker, maintenance should include all of the following EXCEPT ______________. A. changing out of magnetic elements and thermal heaters yearly B. ... for loose or missing parts D. making sure foreign matter does not block tripping element

Last Answer : Answer: A

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : During its operation, loud buzzing and resultant welding of contacts of a magnetic relay may be caused by __________. A. overheating of the contactor coil B. low voltage on the operating coil C. low insulation resistance to ground D. lubrication of the contact bearing points

Last Answer : Answer: B

Description : Air gap readings should be taken periodicly on electrical generation equipment to __________. A. determine the amount of varnish that can be applied to correct insulation problems B. determine the ... field coil bolts and correct lateral adjustment of the field coils D. increase machine efficiency

Last Answer : Answer: B

Description : Before using a volt-ohmmeter to measure resistance readings, you should _____________. A. replace all batteries B. test the insulation resistance of the leads C. make sure the test leads do not touch D. hold the leads together and 'zero' the meter

Last Answer : Answer: D

Description : Compressed air should not be used to clean motor controller equipment because ________________. A. it may force metallic particles into coil insulation B. the surrounding area may need additional cleaning C. the air blast dries out insulation quickly D. a mask and respirator would be required

Last Answer : Answer: A

Description : Air gap readings should be taken on electrical generation machinery periodicly to _________. I. determine the need for cleaning II. check the condition of the bearings A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: B

Description : Air gap readings should be taken on electrical generation equipment periodicly to ________. I. check machine effeciency II. determine the need for cleaning A. I only B. II only C. both I and II D. neither I or II

Last Answer : Answer: D

Description : The greatest detrimental effect on idle electrical equipment, such as cargo pump motors, is the _____________. A. loss of residual magnetism B. absorption of moisture in the insulation C. insulation varnish flaking D. dirt collecting on the windings

Last Answer : Answer: B

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : The most effective method of locating a loose commutator bar in a D.C. motor is by _____________. A. visual inspection B. jiggling each by hand C. sounding each bar with a light weight hammer D. checking with a calibrated torque wrench

Last Answer : Answer: C

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : Which of the listed precautions should be observed before spraying liquid solvent on the insulation of an electric motor? A. Slow the motor down to low speed. B. Disconnect the motor from the power source. C. Secure all ventilation in the area. D. Preheat the insulation to assist in cleaning.

Last Answer : Answer: B

Description : If the pointer on a megger fails to return to 'zero' when not being used, the _____________. A. megger is out of calibration B. megger is operating normally C. hairsprings are burned out D. pointer probably stuck in that position

Last Answer : Answer: B

Description : If the pointer fails to return to zero when a megger is disconnected, the _____________. A. pointer is stuck B. hair springs are burned out C. megger is out of calibration D. megger is operating normally

Last Answer : Answer: D

Description : If deck machinery is expected to be idle for an extended period of time you should____________. A. have electrical safety gloves available in case of electrical shock before running B. perform ... run at regular intervals to inusre correct operation and to renew the internal coating of lubrication

Last Answer : Answer: D

Description : What is a normal indication on a megger when checking insulation?

Last Answer : Infinity.

Description : What is the procedure for using a megger to check the insulation of a conductor?

Last Answer : Connect one lead to the insulation and one lead to the conductor. Turn the handcrank until it starts to slip. Note the reading

Description : What is the normal indication on a megger when checking insulation?

Last Answer : infinity

Description : Why is a Megger used for insulation test and not a multi meter?

Last Answer : With a megger,a voltage of not less than 500 volts DC is used for testing the insulation resistance of windings. With a multi-meter, the voltage used is not more than 3-volts DC. Megger uses high impedance testing and is therefore more accurate than a multi-meter

Description : A megger is to measure insulation resistance of a cable. The cable should be connected to   (a) Battery (b) DC supply (c) AC supply (d) No supply  

Last Answer : majorly in DC as well as AC......but ans is Battery

Description : To measure insulation resistance of equipments of voltage rating upto 440 V the megger generator must generate   (a) 220 V (b) 440 V (c) 500 V (d) None of these 

Last Answer : 500 V

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : When you check the specific gravity of the battery electrolyte with a hydrometer, it should be kept in mind that ____________. A. the battery is fully charged when the indicator floats low in ... taken immediately after water is added to the cell D. temperature has no effect on hydrometer readings

Last Answer : Answer: C

Description : Which of the listed classes of electrical insulation is suited for the highest operating temperature? A. Class 90 (O) B. Class 105 (A) C. Class 130 (B) D. Class 180 (H)

Last Answer : Answer: D

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : The life expectancy of electrical insulation, is approximately halved for an increased operating temperature of _______________. A. 10°C B. 25°C C. 50°C D. 100°C

Last Answer : Answer: A

Description : The most accurate way to evaluate the effectiveness of root planning is by: A. Inspect the root surface with an instrument for root smoothness B. Use air for visual inspection C. Activate a ... the appointment for a decrease oedema and bleeding E. Evaluate the soft tissues 10 to 14 days later.

Last Answer : E. Evaluate the soft tissues 10 to 14 days later.

Description : A low voltage source is being used for testing armature coils. A coil short circuit will be indicated by a _______. A. high voltage reading, while the other coil readings will have an ... the other coil readings are steady D. steady voltmeter reading, while the other coil readings are fluctuating

Last Answer : Answer: B

Description : When troubleshooting electronic equipment, you should use a high impedance multimeter ________________. A. to prevent excess current flow through the meter that would damage it B. for AC measurements only ... being tested D. so as not to load down the circuit and obtain erroneous voltage readings

Last Answer : Answer: D