Cleaning of electrical insulation should be _____________. A. done every six months B. accomplished every 12 months C. determined by need and not the calendar D. performed whenever the electrician is not otherwise busy

1 Answer

Answer :

Answer: C

Related questions

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : When maintenance personnel are working on electrical equipment, all supply switches should be secured in the open position and tagged specifically by the _____________. A. watch engineer B. chief engineer or first assistant C. chief electrician D. person performing the repair

Last Answer : Answer: D

Description : As part of a routine maintenance program for deck machinery, you should ___________. A. inspect electrical wiring and pushbutton switches for evidence of corrosion or burned insulation B. disassemble ... covers and ventilate as weather permits D. Check drum switch contact pressure every three months

Last Answer : Answer: A

Description : The need for insulation cleaning may be determined by _____. A. visual inspection for dirt accumulation B. high megger readings C. low operating temperature D. the time period since the last cleaning

Last Answer : Answer: A

Description : Which of the listed conditions could indicate the need for cleaning electrical insulation? A. Low ambient temperature B. Low operating temperature C. High dielectric strength D. Low megger readings

Last Answer : Answer: D

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : Electrical failures in motors are caused by the breakdown of insulation, which may be caused by _____________. A. penetration of moisture B. accumulation of dirt C. overheating D. all of the above

Last Answer : Answer: D

Description : Electrical insulation is classed by the _____________. A. International Association of Electrical Manufacturers B. approximate operating voltage and current expected C. U.S. Coast Guard D. temperature stability of the manufacturing material(s)

Last Answer : Answer: D

Description : The greatest detrimental effect on idle electrical equipment, such as cargo pump motors, is the _____________. A. loss of residual magnetism B. absorption of moisture in the insulation C. insulation varnish flaking D. dirt collecting on the windings

Last Answer : Answer: B

Description : Grounds occurring in electrical machinery as a result of insulation failure may result from _____________. A. deterioration through extended use B. excessive heat C. extended periods of vibration D. all of the above

Last Answer : Answer: D

Description : The insulation resistance of electric equipment and machinery should be tested for the lowest normal insulation values _____________. A. immediately after shutting down the machine B. every time the brush rigging is ... starting up the machine D. every 30 days whether the machine is in use or not

Last Answer : Answer: A

Description : To repair a small electrical motor that has been submerged in saltwater, you should _____________. A. wash it with fresh water and apply an external source of heat B. renew the windings ... electrical parts with a carbon tetrachloride cleaning solvent and then blow dry the motor with compressed air

Last Answer : Answer: A

Description : The electrician reports to you that he has obtained low (but above 1 megohm) megger readings on the windings of a deck winch motor. Upon checking the records of that motor, you find the readings have ... yea A. motor be replaced B. windings be dried C. windings be cleaned D. readings are acceptable

Last Answer : Answer: D

Description : The period of currency of IPO with second commission a) Three calendar month from the last day of the month the IPO was issued b) Six month from the last day of the month the IPO was issued c) 24 months d) 36 months

Last Answer : d) 36 months

Description : In order to safely carry out repairs to a generator circuit breaker, it must be isolated from the bus. This is accomplished by opening the _____________. A. reverse power relay B. bus disconnect link C. generator bus fuse connections D. power directional relay

Last Answer : Answer: B

Description : Equalization of the power factors of two alternators operating in parallel is accomplished _____________. A. manually, by adjusting the governor controls B. automatically, by automatic voltage regulators ... the output of current transformers D. automatically, by the designed action of the governors

Last Answer : Answer: B

Description : In a logic circuit, the NOT gate function _____________. A. does not alter a logical input B. serves to amplify a given signal level C. must be accomplished with a common collector transistor arrangement D. reverses an input logic condition

Last Answer : Answer: D

Description : Capacitors can be used in electric distribution systems to improve power factor. This is accomplished by seesawing energy between the capacitor and the _____________. A. generator B. inductive loads C. resistive loads D. all of the above

Last Answer : Answer: B

Description : The conversion of the throttle command voltage to the signal necessary to achieve the desired shaft RPM is accomplished by the _____________. A. ahead or astern function generator of the ... circuit C. operational amplifiers in the autorotation circuit D. long time constant amplifier circuit

Last Answer : Answer: A

Description : The standard procedure for maintaining the charge in an emergency diesel starting battery is to trickle charge the battery _____________. A. continuously B. at least once each week C. whenever the charge falls to 75% of full charge D. whenever the electrolyte specific gravity falls to 1.250 or lower

Last Answer : Answer: A

Description : An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR 199) require that each lifesaving appliance, including lifeboat equipment, must be inspected at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : Compressed air should not be used to clean motor controller equipment because ________________. A. it may force metallic particles into coil insulation B. the surrounding area may need additional cleaning C. the air blast dries out insulation quickly D. a mask and respirator would be required

Last Answer : Answer: A

Description : As shown in the illustration, what maintenance would be required of the circuit components? EL-0058 A. Change out both 'C' units monthly. B. Clean the glass surrounding 'E1' & 'E2' as needed. C. File ... upper end of 'G' every six months. D. Take megger readings on 'E1' & 'E2' windings quarterly.

Last Answer : Answer: B

Description : Prilling of urea should be accomplished (in a sprayer) just above the melting point of urea with minimum of retention time, otherwise it will result in (A) Low bulk density product (B) Biuret formation (C) Non-spherical prills (D) Substantially wet non-flowing and sticky product

Last Answer : (B) Biuret formation

Description : The delivery of goods by one person to another for some purpose, upon a contract and that they shall, when the purpose is accomplished, be returned or otherwise disposed of by accounting to the ... then it is called: A. Contingent contract B. Bailment C. Pledge D. Contract of indemnity

Last Answer : B. Bailment

Description : Routine maintenance of a ship's service alternator should include ______________. A. changing the pedestal bearing insulation yearly B. megger testing of all rectifying diodes C. lubricating excitation slip rings D. periodic cleaning of the air filters or screens

Last Answer : Answer: D

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : Which of the listed precautions should be observed before spraying liquid solvent on the insulation of an electric motor? A. Slow the motor down to low speed. B. Disconnect the motor from the power source. C. Secure all ventilation in the area. D. Preheat the insulation to assist in cleaning.

Last Answer : Answer: B

Description : The emergency electrical power source on tank vessels over 500 GT on an international voyage, should be capable of continuous operation under emergency load for _____________. A. 6 hours B. 12 hours C. 18 hours D. 24 hours

Last Answer : Answer: C

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : The insulation of electric generators during short idle periods should be _____________. A. allowed to cool slowly to ambient temperatures B. flashed with direct current to remove any residual ... using strip or space heaters D. relieved of all capacitive charge by grounding the conductors

Last Answer : Answer: C

Description : When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is _____________. A. grounded B. good C. shorted D. dirty

Last Answer : Answer: B

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter pointer _____________. A. fluctuating around a ... slightly downscale as voltage is applied D. continually rising as the test voltage is applied

Last Answer : Answer: C

Description : When a megohmmeter is used to test the dielectric strength of wire insulation, the initial dip of the pointer toward 'zero' is caused by _____________. A. good insulation B. the leakage of ... of dirty insulation C. the capacitance of the circuit D. the dielectric absorption effect of the insulation

Last Answer : Answer: C

Description : Before using a volt-ohmmeter to measure resistance readings, you should _____________. A. replace all batteries B. test the insulation resistance of the leads C. make sure the test leads do not touch D. hold the leads together and 'zero' the meter

Last Answer : Answer: D

Description : The existing resistance of a conductor is dependent upon its length, cross-sectional area, _____________. A. temperature and insulation B. material and insulation C. resistive coefficient and material D. material and temperature

Last Answer : Answer: D

Description : When the current flow through a copper wire increases, its _____________. A. resistance will decrease B. insulation will burn C. temperature will increase D. conductivity will increase

Last Answer : Answer: C

Description : When a megohmmeter is being used to test insulation resistance, current leakage along the surface of the insulation is indicated by the megohmmeter's pointer _____________. A. dipping toward ... kicking slightly down scale as voltage is applied D. fluctuating around a constant resistance reading

Last Answer : Answer: C

Description : When using a megohmmeter to test insulation, good insulation will be indicated by _____________. A. slight kicks of the needle down scale B. a downward dip followed by a gradual climb to the true resistance ... C. a gradual rise in the pointer reading at the outset D. the initial dip of the pointer

Last Answer : Answer: B

Description : When a megohmmeter is used to test insulation, the gradual rise of the pointer reading as a result of continued cranking, is caused by _____________. A. good conductor resistance B. the ... insulation C. the inductive reactance of the windings D. the dielectric-absorption effect of the insulation

Last Answer : Answer: D

Description : On tank vessels with an electrically-driven capstan, the motor should be meggered periodically to test _____________. A. insulation resistance B. eddy currents C. capacitance D. armature reactance

Last Answer : Answer: A

Description : The period of cleaning of a slow sand filter, is usually (A) 5 to 10 days (B) Two weeks to three weeks (C) One month to three months (D) Three months to six months

Last Answer : (C) One month to three months

Description : An audit plan is a a. Detailed plan of analytical procedures and all substantive tests to be performed in the course of the audit. b. Document that provides an overview of the company and a ... process. d. Budget of the time that should be necessary to complete each phase of the audit procedure

Last Answer : Document that provides an overview of the company and a general plan for the audit work to be accomplished, timing of the work, and other matters of concern to the audit.

Description : An audit program is a. A generic document that auditing firms have developed to lead the process of the audit through a systematic and logical process. b. An overview of the company and a general ... d. A budget of the time that should be necessary to complete each phase of the audit procedures

Last Answer : The detailed plan of audit procedures to be performed in the course of the audit.

Description : Which of the following statements concerning electrical cables is correct? A. Where they pass through watertight bulkheads, they should be fitted with watertight stuffing boxes. B. Electric cable coverings should ... , or glued in place where nonmetallic insulation is used. D. All of the above.

Last Answer : Answer: A

Description : The removal of paint from electrical equipment, such as generators, should be cautiously undertaken because ____________. A. the mechanical shock of paint removal lessens the dielectric strength ... phase windings frequently become isolated from each other due to dust interference at the terminals

Last Answer : Answer: B

Description : On some electrical generating equipment one outboard bearing pedestal is insulated from the bedplate. To check this insulation with the machine assembled you should use a____________. A. millivolt meter and a jumper B. ohmmeter C. megohm meter D. high potential tester

Last Answer : Answer: A