x

what is a pony motor ?

91 views

1 Answer

Answer :

pony motor is a small induction motor
Like 0 like

Please log in or register to answer this question.

Related Questions


What is pony motor starting?
Last Answer : In this method the rotor is made to rotate by some external device called pony motors. Once the rotor attains synchronous speed, the DC excitation to the rotor is switched on. Once synchronism is established the pony motor is decoupled. The synchronous motor continuously runs at synchronous speed.

Show More

2 views 1 answer



107 views 0 answers



A pony motor is basically a?
Last Answer : Pony motor is basically a small induction motor.

Show More

111 views 1 answer



The heating time constant of a totally enclosed motor is relatively Select one: a. higher b. lower c. independent of type of enclosure. d. small .
Last Answer : B

Show More

300 views 1 answer



The efficiency of a 3-phase, star connected synchronous motor is 95% and it takes 24A at full load and unity power factor. What will be the induced e.m.f. if total mechanical power developed at full load and 0.9 power factor leading is 14620W. The synchronous impedance per phase is (0.2+j2) Ω.

Show More

180 views 0 answers



Split phase induction motor
Last Answer : Split phase induction motor : There are two windings used in split phase induction motor. It is a type of single-phase induction motor. There are two winding one is called main winding and ... motor have low starting torque it is used for small fans, blowers, centrifugal pumps, grinders etc.

Show More

233 views 1 answer



Describe the reason of using dc series motor for electric trains.
Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Show More

142 views 1 answer



Which motor is generally used in Tap Recorders? A) universal motor B) reluctance motor C) split phase motor D) hysteresis motor
Last Answer : Which motor is generally used in Tap Recorders? A) universal motor B) reluctance motor C) split phase motor D) hysteresis motor

Show More

71 views 1 answer



A 200 V dc motor takes a field current of 2 A to generate a back emf of 180 V. If the field winding resistance is 80 Ω, the resistance of the shunt field regulator is (A) 10 Ω (B) 20 Ω (C) 100 Ω (D) 180 Ω

Show More

77 views 0 answers



As the speed increases, the torque developed by a dc servo motor (A) decrease with a negative slope (B) increases with a positive slope (C) remain constant (D) becomes unstable 

Show More

69 views 0 answers



The starting torque of a V/f controlled inverter-fed 3-phase induction motor operating at 25 Hz as compared with the same motor operating at 50 Hz is (A) more (B) double (C) equal (D) less 

Show More

62 views 0 answers



Regenerative breaking of ac-dc converter fed dc motor is possible when firing delay angle of SCRs is (A) 30° (B) 60° (C ) 90° (D) 120°

Show More

64 views 0 answers



In slip-energy recovery scheme of converter-fed 3-phase induction motor, super synchronous speeds are possible by (A) injecting voltage into the stator (B) injecting voltage into the rotor (C) extracting voltage from the stator (D) extracting voltage from the rotor. 

Show More

70 views 0 answers



Fast acceleration and high-speed cruising electric traction drive motor is (A) separately excited dc motor (B) DC series motor (C) AC series motor (D) 3-phase squirrel cage induction motor 

Show More

72 views 0 answers



 As compared to a split phase motor, a capacitor start motor has _____.
Last Answer :  As compared to a split phase motor, a capacitor start motor has higher starting torque.

Show More

147 views 1 answer



For very low speed and high power applications the best suited ac motor is:
Last Answer : For very low speed and high power applications the best suited ac motor is: synchronous motor

Show More

139 views 1 answer



If the current in the armature of do series motor is reduced to 5%, the torque of the motor will become: (1) 50% of the previous value (2) 25% of the previous value (3) 150% of the previous value (4) 125% of the previous value
Last Answer : If the current in the armature of do series motor is reduced to 5%, the torque of the motor will become: 25% of the previous value

Show More

1.2k views 1 answer



For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is  (A) 15 (B) 30 (C) 60 (D) 90
Last Answer : For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is 30 

Show More

505 views 1 answer



The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 ... .5 A from the same source will be  (A) 48.0% (B) 57.1% (C) 59.2% (D) 88.8%
Last Answer : The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 rpm drawing a current of 3.5 A from the same source will be 48.0%

Show More

502 views 1 answer



The following motor definitely has a permanent magnet rotor  (A) DC commutator motor (B) Brushless dc motor (C) Stepper motor (D) Reluctance motor
Last Answer : The following motor definitely has a permanent magnet rotor Stepper motor

Show More

304 views 1 answer



A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW
Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Show More

363 views 1 answer



In a stepper motor, the detent torque means  (A) minimum of the static torque with the phase winding excited (B) maximum of the static torque with the phase winding excited (C) minimum of ... torque with the phase winding unexcited (D) maximum of the static torque with the phase winding unexcited
Last Answer : In a stepper motor, the detent torque means maximum of the static torque with the phase winding unexcited

Show More

752 views 1 answer



The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A
Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Show More

458 views 1 answer



In case of split phase motor, the phase shift between currents in the two windings is around  A) 30° B) 70° C) 90° D) 120°
Last Answer : In case of split phase motor, the phase shift between currents in the two windings is around  30°

Show More

200 views 1 answer



Which type of motor is most suitable for computerprinter drive?  A) Reluctance motor B) Hysteresis motor C) Shaded pole motor D) Stepper motor
Last Answer : Stepper motor type of motor is most suitable for computer printer drive?.

Show More

173 views 1 answer



The torque speed characteristic of a repulsion motor resembles which of the following d.c. motor characteristics  A) Separately excited B) Shunt C) Series D) Compound
Last Answer : The torque speed characteristic of a repulsion motor resembles which of the following d.c. motor characteristics Series 

Show More

590 views 1 answer



In a Synchronous motor, the magnitude of stator back e.m.f (Eb) depends on
Last Answer : In a Synchronous motor, the magnitude of stator back e.m.f (Eb) depends on DC excitation only

Show More

174 views 1 answer



When running under no-load condition and with over excitation, armature current Ia drawn by a synchronous motor
Last Answer : When running under no-load condition and with over excitation, armature current Ia drawn by a synchronous motor Leads the applied voltage

Show More

539 views 1 answer



A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Show More

489 views 1 answer



Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Show More

88 views 1 answer



In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Show More

137 views 1 answer



A change of 4% in the supply voltage to an induction motor will produce a change of approximately
Last Answer : A change of 4% in the supply voltage to an induction motor will produce a change of approximately 8% in the rotor torque

Show More

491 views 1 answer



A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

343 views 1 answer



In an induction motor if the flux density is reduced to one-half, of its normal value then the torque will  (1) reduce to one-half (2) reduce to one-fourth (3) remain unchanged (4) increase four times
Last Answer : In an induction motor if the flux density is reduced.to one-half, of its normal value then the torque will reduce to one-fourth

Show More

374 views 1 answer



The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above
Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Show More

239 views 1 answer



The number of poles of 8/6 stepper motor can be :
Last Answer : The number of poles of 8/6 stepper motor can be : 4

Show More

286 views 1 answer



In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :
Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Show More

112 views 1 answer



For using regenerative breaking, the most suitable motor is :  (A) DC series motor  (B) Slip ring induction motor  (C) Squirrel cage induction motor  (D) Synchronous motor
Last Answer : For using regenerative breaking, the most suitable motor is : Slip ring induction motor

Show More

93 views 1 answer



Slip test is performed to determine :  (A) Slip in an induction motor  (B) Xd and Xq in a salient pole alternator  (C) Synchronous impedance in an alternator  (D) Positive and negative sequence impedances of an alternator
Last Answer : Slip test is performed to determine :  Xd and Xq in a salient pole alternator 

Show More

163 views 1 answer



Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be
Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Show More

435 views 1 answer



The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 
Last Answer : The slip of 400 V, three phase, 4 -pole induction motor when rotating at 1440 rpm is 4 percent

Show More

365 views 1 answer



A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for
Last Answer : A 400 V, 50 Hz three-phase induction motor rotates at 1440 rpm on full -load. The motor is wound for 4 poles

Show More

311 views 1 answer



The function of a brush and commutator arrangement in a dc motor is to  (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking
Last Answer : The function of a brush and commutator arrangement in a dc motor is to produce unidirectional torque

Show More

2.5k views 1 answer



The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm
Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Show More

158 views 1 answer



In a split-phase induction motor, the resistance/reactance ratios of windings are such that (A) current in the auxiliary winding leads the current in the main winding (B) current in the ... (C) both windings develop the same starting torque (D) both windings develop high starting current
Last Answer : In a split-phase induction motor, the resistance/reactance ratios of windings are such that current in the auxiliary winding leads the current in the main winding

Show More

107 views 1 answer



In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor
Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Show More

95 views 1 answer



The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu
Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Show More

100 views 1 answer



The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.
Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Show More

575 views 1 answer



A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60
Last Answer : 0

Show More

2.1k views 2 answers



An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW
Last Answer : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is 83.33 kW

Show More

180 views 1 answer