121 views

1 Answer

Answer :

If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

Like 0 like

Please log in or register to answer this question.

Related questions

308 views

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

1 answer
203 views

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

1 answer
582 views

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

1 answer
106 views

Description : The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

0 answers
227 views

Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

1 answer
158 views

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

1 answer
176 views

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

1 answer
106 views

Description : In a synchronous motor which losses varies with load?

Last Answer : In a synchronous motor, copper losses varies with load.

1 answer
249 views

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

1 answer
517 views

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

1 answer
77 views

Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

1 answer
101 views

Last Answer : Slip-rings in a synchronous motor carry direct current.

1 answer
176 views

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

1 answer
125 views

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

1 answer
118 views

Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

1 answer
260 views

Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

1 answer
150 views

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

1 answer
200 views

Last Answer :  The size of a synchronous motor decreases with the increase in flux density.

1 answer
154 views

Last Answer : The duration of sudden short-circuit test on a synchronous motor is usually about one second.

1 answer
87 views

Last Answer : The construction of a synchronous motor resembles an alternator.

1 answer
264 views

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

1 answer
111 views

Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

1 answer
97 views

Description : Which motor have more efficiency, synchronous motor or induction motor?

Last Answer : Synchronous motor has more efficiency.

1 answer
108 views

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

1 answer
310 views

Description : How can we reverse the direction of rotation of synchronous motor?

Last Answer : By reversing supply phase sequence we can reverse the direction of rotation of synchronous motor.

1 answer
1.5k views

Description : What is the maximum value of torque angle in synchronous motor?

Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

1 answer
101 views

Description : Hunting in synchronous motor cannot be due to?

Last Answer : Hunting in synchronous motor cannot be due to windage friction.

1 answer
162 views

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

1 answer
507 views

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

1 answer
170 views

Description : An unexcited single phase synchronous motor is ?

Last Answer : An unexcited single-phase synchronous motor is reluctance motor.

1 answer
132 views

Description : A synchronous motor can be made self starting by providing?

Last Answer : A synchronous motor can be made self-starting by providing damper bar.

1 answer
70 views

Description : The back emf of synchronous motor depends on?

Last Answer : The back emf of synchronous motor depends on load angle.

1 answer
95 views

Description : Synchronous motor always runs at which speed?

Last Answer : Synchronous motor always runs at synchronous speed.

1 answer
92 views

Description : Can we use the synchronous motor as the synchronous capacitor?

Last Answer : Yes, we can use the synchronous motor as the synchronous capacitor when the synchrnous motor is overexcited.

1 answer
377 views

Description : what will happen when excitation of an unloaded salient pole synchronous motor suddenly gets disconnected?

Last Answer : When excitation of an unloaded salient pole synchronous motor suddenly gets disconnected the motor will stop.

1 answer
97 views

Description : Three phase synchronous motor will have how many sliprings?

Last Answer : Three phase synchronous motor will have two sliprings.

1 answer
173 views

Last Answer : If the supply frequency to the transformer is increased, the iron loss will increase.

1 answer
9 views

Description : microproject on synchronised UJT triggring circuit

0 answers
571 views

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

2 answers
169 views

Description : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of?

Last Answer : In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of less than 15A.

1 answer
438 views

Description : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then (A) It would over-run the other alternator (B) Its rotor ... (C) Its portion of share in load will increase (D) Its power factor would be decreased.

Last Answer : While keeping the excitation constant, if the steam supply of an alternator running in parallel with another identical alternator is increased, then Its portion of share in load will increase

1 answer
116 views

Description : In an actual transformer the iron loss remains practically constant from no load to full load because?

Last Answer : In an actual transformer the iron loss remains practically constant from no load to full load because core flux remains practically constant.

1 answer
132 views

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

1 answer
354 views

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

1 answer
794 views

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Last Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

1 answer
113 views

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

1 answer
100 views

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

1 answer
504 views

Description : A change of 4% in the supply voltage to an induction motor will produce a change of approximately

Last Answer : A change of 4% in the supply voltage to an induction motor will produce a change of approximately 8% in the rotor torque

1 answer
92 views

Last Answer : If a D.C. series motor is operated on A.C. supply, it will spark excessively, have poor efficiency, have poor power factor.

1 answer
...