Please Log in or Register for more.


252 views

1 Answer

Answer :

In D.C. generators, current to the external circuit from armature is given through commutator commutator.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar

Show More

165 views 2 answers








Last Answer : In D.C. generators the polarity of the interpoles is the same as that of the main pole ahead.

Show More

138 views 1 answer








Last Answer : For the parallel operation of two or more D.C. compound generators, we should ensure that series fields of all generators should be either on positive side or negative side of the armature.

Show More

179 views 1 answer








Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

Show More

151 views 1 answer








Last Answer : D.C. generators are connected to the busbars or disconnected from them only under the floating condition to avoid sudden loading of the primemover, to avoid mechanicaljerk to the shaft, to avoid burning of switch contacts.

Show More

94 views 1 answer








Last Answer : In D.C. generators, the brushes on commutator remain in contact with conductors which lie under interpolar region.

Show More

223 views 1 answer








Last Answer : In D.C. generators the pole shoes are fastened to the pole core by counter sunk screws.

Show More

207 views 1 answer








Last Answer : D.C. generators are installed near the load centres to reduce line losses.

Show More

154 views 1 answer








Last Answer : D.C. generators are normally designed for maximum efficiency around full-load.

Show More

102 views 1 answer







The armature of D.C. generator is laminated to (a) reduce the bulk (b) provide the bulk (c) insulate the core (d) reduce eddy current loss

Show More

15 views 0 answers







DC GENERATORS MCQ
Last Answer : 101. Wave winding is composed of (a) any even number of conductors (b) any odd number of conductors (c) that even number which is exact multiple of poles + 2 (d) that even number ... increase the field resistance (c) increase the speed of primemover (d) check armature insulation resis¬tance Ans: a

Show More

105 views 3 answers







Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound
Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Show More

123 views 1 answer







In DC generators lamination core are generally made of?
Last Answer : In DC generators lamination core are generally made of silicon steel.

Show More

253 views 1 answer







The resistance of armature winding depends on (a) length of conductor (b) cross-sectional area of the conductor (c) number of conductors (d) all of the above

Show More

6 views 0 answers







The field coils of D.C. generator are usually made of (a) mica (b) copper (c) cast iron (d) carbon
Last Answer : Ans: b (b) copper

Show More

32 views 1 answer







Which of the following could be lamina-proximately the thickness of laminations of a D.C. machine ? (a) 0.005 mm (b) 0.05 mm (c) 0.5 m (d) 5 m

Show More

6 views 0 answers







Laminations of core are generally made of (a) case iron (b) carbon (c) silicon steel (d) stainless steel

Show More

3 views 0 answers








Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Show More

144 views 1 answer








Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Show More

158 views 1 answer








Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Show More

151 views 1 answer








Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Show More

121 views 1 answer







For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?
Last Answer : Wave winding

Show More

141 views 1 answer













How Generators Work
Last Answer : How Generators Work Generators are devices which produce electricity. They produce electricity by converting mechanical energy from power sources. Examples would be steam, water, wind and gasoline. These ... can also be used for recreational purposes. Examples would be camping, boating or fishing.

Show More

6 views 1 answer







Why are generators rated in kVA not in kW ?
Last Answer : Because It's rating of generator kva is apparent power. Kw is active power which we use. And one is kvar reactive power.

Show More

116 views 3 answers







Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done
Last Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

Show More

421 views 1 answer







Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz
Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Show More

114 views 1 answer








Last Answer : Large capacity generators are invariably hydrogen cooled.

Show More

95 views 1 answer








Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Show More

138 views 1 answer







In D.C. generators, current to the external circuit from armature is given through (a) commutator (b) solid connection (c) slip rings (d) none of above
Last Answer : Ans: a

Show More

30 views 1 answer








Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Show More

483 views 1 answer







Explain concept of back emf in DC machine. State how it governs armature current. 
Last Answer : Back emf: When the armature of DC machine rotates under the influence of driving torque, the armature conductors move in the magnetic field and cut it and hence emf is induced in them. The ... flow of armature current i.e. it automatically changes the armature current to meet load requirements.

Show More

189 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

329 views 1 answer








Last Answer : The current drawn by the armature of D.C. motor is directly proportional to the torque required.

Show More

582 views 1 answer








Last Answer : In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.

Show More

503 views 1 answer








Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Show More

366 views 1 answer








Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Show More

554 views 1 answer







If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?
Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Show More

277 views 1 answer








Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Show More

129 views 1 answer








Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Show More

251 views 1 answer








Last Answer : In a D.C. machine stray loss is the sum of iron loss and mechanical loss.

Show More

218 views 1 answer








Last Answer : A D.C. generator can be considered as rotating amplifier.

Show More

73 views 1 answer








Last Answer : To avoid formation of grooves in the commutator of a D.C. machine the brushes of opposite polarity should track each other.

Show More

3.0k views 1 answer








Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Show More

136 views 1 answer








Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Show More

95 views 1 answer








Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Show More

128 views 1 answer








Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Show More

226 views 1 answer








Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Show More

600 views 1 answer








Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Show More

785 views 1 answer








Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Show More

239 views 1 answer






Show More⇦ PreviousNext ⇨