1 Answer

Answer :

The material used to make standard resistance is: Manganin

Related questions

Description : In a standard multimeter for measuring AC voltage, parameter of _____ voltage is measured

Last Answer : In a standard multimeter for measuring AC voltage, parameter of RMS voltage is measured

Description : A d.c. potentiometer is designed to measure up to about 2V with a slide wire of 800 mm. A standard cell of emf 1.18V obtains balance at 600 mm. A test cell is seen to obtain balance at 680 mm. The emf0fthe test cell is  A)1.00V B)1.34V C)1.50V D)1.70V 

Last Answer : A d.c. potentiometer is designed to measure up to about 2V with a slide wire of 800 mm. A standard cell of emf 1.18V obtains balance at 600 mm. A test cell is seen to obtain balance at 680 mm. The emf0fthe test cell is 1.34V

Description : A reading of 120 is obtained when a standard inductor was connected in the circuit of a Q-meter and the variable capacitor is adjusted to a value of 300 pF. A lossless capacitor of unknown value Cx is then connected in ... value of 200 pF. The value of Cx in pF is  A) 100 B) 200 C) 300 D) 500

Last Answer : A reading of 120 is obtained when a standard inductor was connected in the circuit of a Q-meter and the variable capacitor is adjusted to a value of 300 pF. A lossless capacitor of unknown value Cx is ... when the variable capacitor is readjusted to a value of 200 pF. The value of Cx in pF is 100 

Last Answer : The EMF of Weston standard cell is measured using Potentiometer.

Last Answer : For measuring emf of a standard cell we use: Potentiometer

Last Answer : Commonly used standard capacitor is concentric cylindrical type.

Last Answer : Standard resistor is made from maganin.

Description : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is A) Manganin wire of 20 m Ω B) Constantan wire of 20 m Ω C) Manganin wire of 25 m Ω D) Constantan wire of 25 m Ω

Last Answer : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is Manganin wire of 25 m Ω

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : An ammeter has a current change of 0-5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of  A) 0.8 ohm in series with the meter B) ... series with the meter C) 0.04 ohm in parallel with the meter D) 0.05 ohm in parallel with the meter

Last Answer : An ammeter has a current change of 0—5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of 0.05 ohm in parallel with the meter

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Description : Resistance grounding is normally used for :  (A) high voltage long over head transmission lines  (B) low voltage short over head transmission lines  (C) extra high voltage long over head transmission lines  (D) all the above

Last Answer : Resistance grounding is normally used for : low voltage short over head transmission lines

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Description : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because  (A) Cables have a low value of capacitance which draws a high ... high value of charging current (D) Cables have a low value of capacitance and initial resistance

Last Answer : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because Cables have a high value of capacitance which draws a high value of charging current

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Last Answer : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Description : The transducer with negative temperature co-efficient of resistance is (A) Thermistor (B) Resistance Thermometer (C) Strain Gauge (D) Thermocouple

Last Answer : The transducer with negative temperature co-efficient of resistance is Thermistor

Last Answer : Low resistance is measured by Kelvin’s double bridge.

Last Answer : The internal resistance of the ammeter should ideally be Zero.

Last Answer : The absolute measurement of resistance is done by Lorenz method.

Last Answer : The internal resistance of an ammeter should be Very small.

Description : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. What is the value of series resistor to be used?

Last Answer : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. 99.99 K ohms is the value of series resistor to be used.

Last Answer : The resistance can be measured most accurately by bridge method.

Last Answer : In a dynamo-meter type of moving coil instrument a swamping resistance is provided inorder to: Provide equal time constant for moving coil and fixed coil, when used for ac measurement

Last Answer : To measure a resistance with the help of a potentiometer it is not necessary to standardise the potentiometer.

Last Answer : For measuring a very high resistance we should use Meggar.

Description : When a capacitor was connected to the terminal of ohmmeter, the pointer indicated a low resistance initially and then slowly came to infinity position. This shows that capacitor is ?

Last Answer : When a capacitor was connected to the terminal of ohmmeter, the pointer indicated a low resistance initially and then slowly came to infinity position. This shows that capacitor is all right.

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Last Answer : Meggar is an instrument which measures the insulation resistance of an electric circuit relative to earth and one another.

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Last Answer : Yes ammeter has its own resistance Not only ammeter every electrical devices has there own resistance practicaly

Last Answer : Voltmeter is used to measure voltage in a circuit.Ohmmeter is used to measure the resistance of a component in a circuit.

Last Answer : Preferred material for permanent magnet is: Alnico