1 Answer

Answer :

The absolute measurement of resistance is done by Lorenz method.

Related questions

Description : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Last Answer : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Description : Which method can be used for absolute measurement of resistance? A. Ohm's law method B. Wheatstone bridge method C. Both A & B D. None of these. 

Last Answer : Wheatstone bridge method can be used for absolute measurement of resistance.

Description :  The absolute measurement of resistance involves the measurement of  a) Length and time b) Length and mass c) Velocity d) Either (a) or (c)

Last Answer :  The absolute measurement of resistance involves the measurement of   d) Either (a) or (c)

Last Answer : The power measurement in a balanced 3-phase circuit can be done by: One wattmeter method, Two wattmeter method, Three wattmeter method.

Description : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Last Answer : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : The function of measurement system is/are _____.

Last Answer : The function of measurement system are indicating, recording and controlling function.

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : The measurement range of an ammeter can be increased by using a:

Last Answer : The measurement range of an ammeter can be increased by using a: low resistance in shunt

Description : Clamp on ammeter is used for measurement of:

Last Answer : Clamp on ammeter is used for measurement of: large alternating currents

Description : Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is   (A)sinusoidal (B) square (C) rectangular (D) triangular

Last Answer : Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is sinusoidal 

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : Integrating principle in the digital measurement is the conversion of   (a) Voltage to time (b) Voltage to frequency (c) Voltage to current (d) Current to voltage

Last Answer : Integrating principle in the digital measurement is the conversion of Voltage to frequency

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is  (1) d,a,c,b (2) d, c, a, b (3) a, c, b, d (4) a, b, c, d

Last Answer : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is d,a,c,b

Description : Accurate measurement of very low resistances is possible with (A) Megger (B) Wheatstone Bridge (C) Kelvin’s Double Bridge (D) Wagner’s Earthing Device

Last Answer : Accurate measurement of very low resistances is possible with Kelvin’s Double Bridge

Last Answer : A measure of the reproducibility of measurement is known as Precision.

Last Answer : MISC meter not recommended for DC measurement because the error is high due to the hysteresis effect.

Last Answer : Ryall crest voltmeter is used for measurement of High AC voltage.

Last Answer : An instrument to be used for measurement and control should preferably have Linear output and fast response

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Last Answer : Kelvin double bridge is best suited for the measurement of: Low resistance

Last Answer : Megger is an instrument used for the measurement of: High resistance and insulation resistance

Last Answer : Hay’s Bridge is suitable for the measurement of: Inductances with Q>10.

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : For measurement of inductance having high value, we should use Hay's bridge.

Last Answer : For measurement of mutual inductance we can use Heaviside bridge.

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : Working principle of manometer comprises of balancing a coloumn of liquid against the pressure to be measured. Inclined tube manometer is especially used for the measurement of __________ pressure. (A) Small differential (B) Atmospheric (C) Absolute (D) Gage

Last Answer : (A) Small differential

Description : The absolute percentage error in the computed discharge over a rectangular weir corresponding to an absolute error of 1.5 % in the measurement of head over the sill of the weir would be : (a) 1.5 (b) 2.25 (c) 2.5 (d) 3.75

Last Answer : (b) 2.25

Description : An ordinal scale is: a. The simplest form of measurement b. A rank-order scale of measurement c. A scale with equal intervals between adjacent numbers d. A scale with an absolute zero point e. A categorical scale

Last Answer : b. A rank-order scale of measurement

Description : Define absolute pressure and gauge pressure. State the different units for pressure measurement.

Last Answer : Definition: Absolute pressure: Absolute pressure is defined as actual total pressure including atmospheric pressure actin On a surface. PAbsolute= PAtmospheric + PGauge Gauge pressure: Gauge pressure is defined ... mm of mercury column (blood pressure) inches of water Barmillibar (weather) Torr

Description : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is A) Manganin wire of 20 m Ω B) Constantan wire of 20 m Ω C) Manganin wire of 25 m Ω D) Constantan wire of 25 m Ω

Last Answer : A 10A DC Ammeter has a resistance of 0.1 Ω is to be extended to 50 A, the required shunt wire is Manganin wire of 25 m Ω

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : An ammeter has a current change of 0-5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of  A) 0.8 ohm in series with the meter B) ... series with the meter C) 0.04 ohm in parallel with the meter D) 0.05 ohm in parallel with the meter

Last Answer : An ammeter has a current change of 0—5A and its internal resistance is 0.2 ohm. In order to Change the range to 0-25 A, wear need to add a resistance of 0.05 ohm in parallel with the meter

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Description : Resistance grounding is normally used for :  (A) high voltage long over head transmission lines  (B) low voltage short over head transmission lines  (C) extra high voltage long over head transmission lines  (D) all the above

Last Answer : Resistance grounding is normally used for : low voltage short over head transmission lines

Description : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is (A) 2.5 W (B) 5 W (C) 32.5 W (D) 35 W

Last Answer : A 200 V, 5 A d.c. energy meter is tested at its marked ratings. The resistance of the pressure circuit is 8000 Ω and that of current coil is 0.1 Ω. The power consumed when testing the meter with phantom loading with current circuit excited by a 6 V battery is 35 W

Description : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because  (A) Cables have a low value of capacitance which draws a high ... high value of charging current (D) Cables have a low value of capacitance and initial resistance

Last Answer : When measuring insulation resistance of cables using d.c. source, the galvanometer used should be initially short circuited because Cables have a high value of capacitance which draws a high value of charging current

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : The transducer with negative temperature co-efficient of resistance is (A) Thermistor (B) Resistance Thermometer (C) Strain Gauge (D) Thermocouple

Last Answer : The transducer with negative temperature co-efficient of resistance is Thermistor

Last Answer : Low resistance is measured by Kelvin’s double bridge.

Last Answer : The internal resistance of the ammeter should ideally be Zero.

Last Answer : The internal resistance of an ammeter should be Very small.

Description : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. What is the value of series resistor to be used?

Last Answer : The full-scale deflection current of an ammeter is 1 mA and its internal resistance is 100Ohm. This is to have full deflection when 100V is measured. 99.99 K ohms is the value of series resistor to be used.

Last Answer : The resistance can be measured most accurately by bridge method.

Last Answer : The material used to make standard resistance is: Manganin

Last Answer : In a dynamo-meter type of moving coil instrument a swamping resistance is provided inorder to: Provide equal time constant for moving coil and fixed coil, when used for ac measurement