1 Answer

Answer :

In series with the shunt winding

Related questions

Description : The number of parallel paths in armature winding of four pole wave winding connected dc machine having 22 coil sides is (1) 4 (2) 22 (3) 2 (4) 11 

Last Answer : Ans- Option (3) because wave winding always have 2 parallel paths

Description :  The number of parallel paths in the armature winding of a 4 -pole, wave connected d.c. machine having 28 coilside is : -  a) 28 b) 14 c) 4 d) 2

Last Answer : 2

Description : Which one of the following statements for a dc machine which is provided with inter pole winding (IW) as well as compensating winding (CW) is correct a) Both IW and CW are connected in ... parallel with Armature winding d) CW connected in series but IW is connected in parallel with Armature winding

Last Answer : Ans: Both IW and CW are connected in series with Armature winding

Description : Sparking of D.C. motor brushes can be caused by __________. A. an open commutating winding B. many mechanical, electrical or operating faults C. an open interpole D. all of the above

Last Answer : Answer: B

Description : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians (A) Armature amp-conductors × (θ/360o) (B) Armature amp-turns × (θ/360o) (C) Armature amp-conductors × (1/4 - θ/360o) (D) Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians Armature amp-conductors × (1/8 - θ/360o)

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : A three-phase, squirrel cage, induction motor will run hot due to a/an ______________. A. improper brush position B. reversed commutating pole C. shorted stator D. high power factor

Last Answer : Answer: C

Description : Relative to the direction of rotation, a D.C. motor commutating pole has the same polarity as the _____________. A. main pole following B. interpole following C. main pole preceding D. interpole preceding

Last Answer : Answer: C

Description : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is  (A) 24 (B) 18 (C) 12 (D) 0

Last Answer : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is 24 

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Description : Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is (A) 48 (B) 24 (C) 192 (D) 96

Last Answer : Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is 24

Description : To carry out an insulation resistance test, one terminal of the megohmmeter should be connected to the winding, with the other terminal being connected to the ____________________. A. power supply B. variable resistor C. frame of the machine D. armature

Last Answer : Answer: C

Description : A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is (A) 1000 kVA (B) 1100 kVA (C) 11000 kVA (D) 12100 kVA

Last Answer : A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is 12100 kVA

Description : Why shaded-pole single phase induction motor does not need any special starting technique like capacitors and auxiliary winding etc.

Last Answer : Because it is inherently self started motor. The construction of the poles is such that they give a sweep to the magnetic flux and motor starts rotating.

Description : In DC generators, armature reaction is produced actually by (A) Its field current. (B) Armature conductors. (C) Field pole winding. (D) Load current in armature.

Last Answer : Ans: D Because load current in armature gives rise to armature mmf which react with main field mmf.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : If only one brush on a commutator is sparking excessively, you should look for _____________. A. a high commutator bar B. copper imbedded in the brush C. a loose commutator bar D. flux in the commutating zone

Last Answer : Answer: B

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : In D.C. motor construction, commutating windings are wound on _________________. A. opposite main poles B. interpoles C. adjacent main poles D. the rotor core

Last Answer : Answer: B

Description : Basic electrical motor action depends on _______________. A. a conductor rotated within a magnetic field B. a current carrying conductor placed in a magnetic field C. the relative force of the commutator and commutating poles D. the relative force of the armature and interpoles

Last Answer : Answer: B

Description : An AC circuit has capacitance arranged in series. If the line voltage remains constant, the capacitive reactance value can be varied by changing the _____________. A. line frequency B. resistance C. number of commutating poles D. number of interpoles

Last Answer : Answer: A

Description : Modern DC generators are fitted with commutating poles to _____________. A. prevent motorizing B. reduce sparking C. reduce the load on the main poles D. reduce spring pressure on the brushes

Last Answer : Answer: B

Last Answer : The number of conductors of the compensating winding in a D.C. machine is always less than the number of armature conductors per pole.

Description : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is

Last Answer : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is 990.

Description : The function(s) of pole shoes in DC machine is/ are to : -  a) Support the field coils b) Reduce the reluctance of the magnetic path c) Spread out the flux to achieve uniform flux distribution in the air gap d) All of the above.

Last Answer : Support the field coils

Description : A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of the rotor is in the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be

Last Answer : A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of ... the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be 140 Hz.

Description : The hook-on AC volt-ammeter consists essentially of a split-core and a rectifiertype instrument connected to the secondary winding of a _____________. A. potential transformer B. control transformer C. current transformer D. reactance transformer

Last Answer : Answer: C

Description : A megohmmeter is connected to each end of an individual motor winding. A low ohm reading indicates ____________. A. an open coil B. a loose coil C. good continuity D. a dirty coil

Last Answer : Answer: C

Description : If you obtain a low resistance reading with a megohmmeter connected between terminals 'A' and 'C' of the three-phase, wye-connected winding shown in the illustration, there is __________. EL-0074 A. no open circuit ... 'B' C. an open circuit between 'A' and 'C' D. an open circuit in both windings

Last Answer : Answer: A

Description : Which of the two main types of rotors can have either a single winding or three Y-connected windings?

Last Answer : The drum or wound rotor.

Description : In a capacitor start single-phase induction motor, the capacitor is connected (A) in series with main winding. (B) in series with auxiliary winding. (C) in series with both the windings. (D) in parallel with auxiliary winding.

Last Answer : Ans: B To make single phase motor self start. We split the phases at 90 degree. Hence, motor behaves like a two phase motor.

Description : On large generators, space heaters are used to ____________. A. keep the machine at ambient tmperature of the machinery space B. maintain rotor and stator winding temperatures above the dew point ... C. prevent condensation in the lube oil D. prevent electrolysis due to condensation in the bearings

Last Answer : Answer: B

Description : The purpose of a cage rotor winding placed on the rotor of a synchronous motor is to _____________. A. provide excitation to the DC field B. start the machine as an induction motor C. contribute extra torque at synchronous speed D. prevent the machine from falling out of step

Last Answer : Answer: B

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : Electrode that is connected to the posi- tive pole of the battery is called?

Last Answer : Anode

Description : Why totem pole outputs cannot be connected together.

Last Answer : Totem pole outputs cannot be connected together because such a connection might produce excessive current and may result in damage to the devices.

Description : A DC reactor is connected in series with each pole of a converter station in order to: A) prevent commutation failures in the inverter B) supply reactive power to the converter C) improve system stability D) increase the power transfer capability

Last Answer : A DC reactor is connected in series with each pole of a converter station in order to:  prevent commutation failures in the inverter

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : A three phase, salient pole synchronous motor is connected to an infinite bus. It is operated at no load a normal excitation. The field excitation of the motor is first reduced to zero ... First increases and then decreases steeply (C) First decreases and then increases steeply (D) Remains constant

Last Answer : B

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : In a dc generator why does total flux per pole decrase if the load on the machine increases even thought the field current is constsn?

Last Answer : Due to armature reaction

Description : An open shunt field in a direct current machine may be located by connecting the field circuit to an external power source, equal to the rated field voltage or less, and tested with a voltmeter from ... C. any suitable ground to any available line lead D. any field pole to each field coil lead

Last Answer : Answer: A

Description : A three-phase, induction-type motor experiences an open in one phase. Which of the listed automatic protective devices will prevent the machine from being damaged? A. Overspeed trip B. Thermal overload relay C. Three-pole safety switch D. Magnetic blowout coil

Last Answer : Answer: B

Description : In a salient pole synchronous machine (usual symbols are used): (A) xq > xd (B) xq = xd (C) xq < xd (D) 0

Last Answer : Ans: C Since reluctance on the q axis is higher, owing to the larger air gap, hence xq < xd

Description : In a four-pole D.C. machine (a) all the four poles are north poles (b) alternate poles are north and south (c) all the four poles are south poles (d) two north poles follow two south poles

Last Answer : Ans: b

Description : A pole pitch in electrical machine is: (1) Equal to 180° electrical (2) Equal to 180° mechanical (3) Less than 180° electrical (4) Greater Than 180° electrical

Last Answer : A pole pitch in electrical machine is: Equal to 180° electrical

Description : A separately excited d.c. machine is coupled to a 50 Hz, three-phase, 4-pole induction machine as shown in the figure. The Dc machine is energized first and the machines rotate at 1 600 ... three phase source, the phase sequence being consistent with the direction of rotation. In steady state

Last Answer : A separately excited d.c. machine is coupled to a 50 Hz, three-phase, 4-pole induction machine as shown in the figure. The Dc machine is energized first and the machines rotate at 1 600 1pm. ... rotation. In steady state DC machine acts as a motor and the induction machine acts as a generator