A DC reactor is connected in series with each pole of a converter station in order to: A) prevent commutation failures in the inverter B) supply reactive power to the converter C) improve system stability D) increase the power transfer capability

1 Answer

Answer :

A DC reactor is connected in series with each pole of a converter station in order to:  prevent commutation failures in the inverter

Related questions

Description : A variable shunt, connected across the series field coils of a DC compound wound generator, to permit adjustment of the degree of compounding, is called a _____________. A. divider B. diverter C. converter D. rheostat

Last Answer : Answer: B

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : Which one of the following statements for a dc machine which is provided with inter pole winding (IW) as well as compensating winding (CW) is correct a) Both IW and CW are connected in ... parallel with Armature winding d) CW connected in series but IW is connected in parallel with Armature winding

Last Answer : Ans: Both IW and CW are connected in series with Armature winding

Description : The conversion for a first order liquid phase reaction. A → B in a CSTRis 50%. If another CSTR of the same volume is connected in series, then the % conversion at the exit of the second reactor will be (A) 60 (B) 75 (C) 90 (D) 100

Last Answer : (B) 75

Description : What is the proper procedure for suppressing electrical noise in a mobile station? A. Apply shielding and filtering where necessary B. Insulate a all plain sheet metal surfaces from each other C. ... -static spray liberally to all nonmetallic D. Install filter capacitors in series with all dc wiring

Last Answer : A. Apply shielding and filtering where necessary

Description : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians (A) Armature amp-conductors × (θ/360o) (B) Armature amp-turns × (θ/360o) (C) Armature amp-conductors × (1/4 - θ/360o) (D) Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians Armature amp-conductors × (1/8 - θ/360o)

Description : The number of parallel paths in armature winding of four pole wave winding connected dc machine having 22 coil sides is (1) 4 (2) 22 (3) 2 (4) 11 

Last Answer : Ans- Option (3) because wave winding always have 2 parallel paths

Last Answer : Req= (1/1200 +1/560 + 1/2.1)^-1        = 2.1 ohms RT= 2.1 + 7.8      = 9.9 ohms IT = V/R = 24/9.9                = 2.4 A Veq= R I =  2.1 2 ... 7.8         = 12.096 w                 = 44.928 w _________________________________________ By: Ellis-Junior Kamatjipose [email protected]

Description : A hydraulic turbine having rated speed of 250 rpm is connected to a synchronous generator. In order to produce power at 50 Hz, the number of poles required in the generator are (A) 6 (B) 12 (C) 16 (D) 24

Last Answer : A hydraulic turbine having rated speed of 250 rpm is connected to a synchronous generator. In order to produce power at 50 Hz, the number of poles required in the generator are 24

Description : Backmixing is most predominant in (A) A well stirred batch reactor (B) A plug-flow reactor (C) A single CSTR (D) CSTR's connected in series

Last Answer : (C) A single CSTR

Description : The purpose of a satellite station' in triangulation can be served by : (a) A Church spire' in order to secure a well- shaped triangle (b) A Flag pole' in order to secure a well- ... a well- shaped triangle (d) An Eccentric station' near the true station whereon the instrument cannot be setup

Last Answer : (d) An ‘Eccentric station’ near the true station whereon the instrument cannot be setup

Description : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the ... the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

Last Answer : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume ... the shaft. The accelerating torque in the generator in MNm at the time of fault will be 1.018 

Description : Which material is used in controlling chain reaction in a nuclear reactor?  A) Thorium B) Uranium C) Boron D)Beryllium

Last Answer : Which material is used in controlling chain reaction in a nuclear reactor?  A) Thorium B) Uranium C) Boron D)Beryllium

Description : What is a converter reactor ?

Last Answer : A reactor plant which is designed to produce more fuel than it consumes. The breeding is obtained by converting fertile material to fissile material.

Description : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is  (A) 96 V (B) 192 V (C) 384 V (D) 768 V

Last Answer : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is 384 V

Description : Two bulbs consume same energy when operated at `200 V and 300 V` , respectively . When these bulbs are connected in series across a dc source of `500

Last Answer : Two bulbs consume same energy when operated at `200 V and 300 V` , respectively . When these bulbs ... ratio of powers consumed across them is `2//3`

Description : Why is it dangerous yo supply power to an unloaded series connected dc motor?

Last Answer : Need answer

Description : A series wound DC motor has its armature and field connected in series with a resistor. When the motor is disconnected from its power supply, this motor will exemplify __________. A. the ... the proper connections for an automatic strip heater C. a reversing controller circuit D. dynamic braking

Last Answer : Answer: D

Description : Which of the methods listed is used to maintain the division of load between two compound-wound, DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt ... generators are connected in series. D. The equalizer connection parallels the series fields of all machines.

Last Answer : Answer: D

Description : The shunt of a DC ammeter should be connected in __________. A. series with the load and in parallel with the meter movement B. parallel with the load and in series with the meter movement C. ... and in parallel with the meter movement D. series with the load and in series with the meter movement

Last Answer : Answer: A

Description : A DC ammeter is always connected ______________. A. in series with a circuit B. in parallel with a circuit C. with internal shunts only D. without regard to polarity

Last Answer : Answer: A

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : Which of the methods listed is used to maintain equal load sharing between two compound wound DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt field rheostats ... are connected in series. D. The series fields of both generators are connected in parallel.

Last Answer : Answer: D

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : A 35 V dc supply is connected across a resistance of 600 ohm in series with an unknown resistance R. A voltmeter having a resistance of 1.2 kOhm is connected across 600 ohm resistances and reads 5 V. The value of resistance R shall be:

Last Answer : A 35 V dc supply is connected across a resistance of 600 ohm in series with an unknown resistance R. A voltmeter having a resistance of 1.2 kOhm is connected across 600 ohm resistances and reads 5 V. The value of resistance R shall be: 2.4 kOhm

Description : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be

Last Answer : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be 2.4 kOhm

Description : A DC voltage source is connected across a series RLC circuit. Under steady-state conditions, the applied DC voltage drops entirely across the

Last Answer : A DC voltage source is connected across a series RLC circuit. Under steady-state conditions, the applied DC voltage drops entirely across the C only

Description : At an industrial sub-station with a 4 MW load, a capacitor of 2 MVAR is installed to maintain the load power factor at 0.97 lagging. If the capacitor goes out of service, the load power factor becomes (A) 0.85 (B) 1.00 (C) 0.80 lag (D) 0.90 lag

Last Answer : At an industrial sub-station with a 4 MW load, a capacitor of 2 MVAR is installed to maintain the load power factor at 0.97 lagging. If the capacitor goes out of service, the load power factor becomes  0.80 lag

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Description : A generating station has a maximum demand of 50 Mw, a load factor of 60%, a plant capacity factor of 45% and if the plant while running as per schedule, were fully loaded. The daily energy produced will be

Last Answer : A generating station has a maximum demand of 50 Mw, a load factor of 60%, a plant capacity factor of 45% and if the plant while running as per schedule, were fully loaded. The daily energy produced will be 720 MW.

Description : A power station supplies the peak load of 60 Mw, 40 MW and 70 MW to three localities. The annual load factor is 0.50 p.u. and the diversity factor of the load at the station is 1.55. The maximum demand on the station and average load respectively will be 

Last Answer : A power station supplies the peak load of 60 Mw, 40 MW and 70 MW to three localities. The annual load factor is 0.50 p.u. and the diversity factor of the load at the station is 1.55. The maximum demand on the station and average load respectively will be 103.2 MW, 51.61 .

Description : High Voltage DC (HVDC) transmission is mainly used for  (A) bulk power transmission over very long distances (C) inter-connecting two systems with same nominal frequency (C) eliminating reactive power requirement in the operation (D) minimizing harmonics at the converter stations

Last Answer : High Voltage DC (HVDC) transmission is mainly used for bulk power transmission over very long distances 

Description : For an existing ac transmission line, the string efficiency is 80%, if dc voltage is supplied for the same setup, the string efficiency will be?

Last Answer : 100%

Description : In a DC transmission line?

Last Answer : In a DC transmission line there are no effects due to inductive and capacitive reactances.

Description : In order to improve the power factor ___ device is employed in the substation a) Synchronous condenser b) Synchronous reactor c) Series Capacitors d) None of the above

Last Answer : Ans: A

Description : N' plug flow reactors in series with a total volume 'V' gives the same conversion as a single plug flow reactor of volume 'V' for __________ order reactions. (A) First (B) Second (C) Third (D) Any

Last Answer : (D) Any

Description : The MIL is illuminated and a battery module deterioration diagnostic trouble code is stored the most like cause is a failed by a) High voltage battery b) High voltage inverter c) Motor/ generator d) DC/ DC converter

Last Answer : a) High voltage battery

Description : In practice, a current source inverter consists of an AC/ DC converter with a large inductance ‘L’ in the output. This inductance maintains a ……… …………through the switching devices over short interval of time. A) constant current B) constant voltage C) constant power D) none of the (A), (B), (C)

Last Answer : In practice, a current source inverter consists of an AC/ DC converter with a large inductance ‘L’ in the output. This inductance maintains a constant current through the switching devices over short interval of time. 

Description : A single-phase fully controlled thyristor bridge ac-dc converter is operating at a firing angle of 25o and an overlap angle of 10o with constant dc output current of 20 A. The fundamental power factor (displacement factor) at input ac mains is  (A) 0.78 (B) 0.827 (C) 0.866 (D) 0.9

Last Answer : A single-phase fully controlled thyristor bridge ac-dc converter is operating at a firing angle of 25o and an overlap angle of 10o with constant dc output current of 20 A. The fundamental power factor (displacement factor) at input ac mains is 0.78

Description : In which type of AC to DC converter efficiency is higher :

Last Answer : In which type of AC to DC converter efficiency is higher : solid state rectifier

Description : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor :  (A) can be operated in first quadrant (B) ... in first & second quadrants (C) can be operated in first & fourth quadrants (D) cannot be operated

Last Answer : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor : can be operated in first & fourth quadrants

Description : A 3 -phase, fully controlled, converter is feeding power into a DC load at a constant current of 150 A, the rms value of the current flowing through each thyristor of the converter is

Last Answer : Please show the solution for this question

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V

Last Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V

Description : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of ... the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

Last Answer : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, ... line. The voltage of the alternator neutral with respect to ground during the fault is 642.2 V

Description : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 ... load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

Last Answer : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/ ... MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be 36 

Description : The 'Equal area criterion' for the determination of transient stability of a synchronous machine connected to an infinite bus  (1) ignores line as well as synchronous machine resistance ... consideration the possibility of machine losing synchronism after it has survived during the first swing.

Last Answer : 1

Description : The sequence components of current of a single-phase load connected to a 3-phase system are (A) equal positive and negative sequence components (B) equal positive, negative and zero sequence components (C) vector sum of sequence currents is zero (D) algebraic sum of sequence currents is zero

Last Answer : The sequence components of current of a single-phase load connected to a 3-phase system are equal positive, negative and zero sequence components

Description : If non-linear loads are connected to the power system, then (A) displacement power factor is same as the total power factor (B) displacement power factor is not equal to the total power ... factor is due to harmonic currents (D) total power factor is due to fundamental component of current

Last Answer : If non-linear loads are connected to the power system, then displacement power factor is not equal to the total power factor

Description : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω

Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω