What are the two methods of connecting the outputs from a  three-phase alternator to the load?

1 Answer

Answer :

Wye and Delta.

Related questions

Description : How many voltage outputs are available from a two-phase three-wire alternator?

Last Answer : Three.

Description : In a three-phase alternator, what is the phase relationship between the individual output voltages?

Last Answer : Each phase is displaced 120º from the other two

Description : at the terminal of a three-phase 6.6Kv alternator a load R=200 ohm is connected between two-phase and the third phase is opened. Z1=z2=5 ohm Zo=2 find out the fault current .

Last Answer : 32A

Description : A three-phase alternator is operating at 450 volts, 250 amps at 0.6 power factor. If the power factor increases to 0.8, the kw load potential will increase by _____________. A. 38.525 kw B. 116.91 kw C. 155.88 kw D. 194.85 kw

Last Answer : Answer: A

Description : Name the various methods for predetermining the voltage regulation of 3-phase Alternator.

Last Answer : The following are the three methods which are used to predetermine the voltage regulation of smooth cylindrical type Alternators · Synchronous impedance / EMF method · Ampere-turn / MMF method · Potier / ZPF method

Description : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is :  (A) capacitive (B) inductive (C) resistive (D) inductive and resistive

Last Answer : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is : capacitive 

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description : What are the methods of connecting 3-phase windings?

Last Answer : There are two methods. a. Star or wye (Y) connection. b. Delta or mesh connection.

Description : If the differential amplifier is configured with a single input and differential outputs, what will the output signals be?

Last Answer : Each output will be a sine wave with a peak-to-peak amplitude of 100 millivolts. The output signals will be 180 degrees out of phase with each other.

Description : How many inputs and outputs are possible with a differential amplifier?

Last Answer : Two inputs, two outputs.

Description : Circuits which maintain constant voltage or current outputs are called dc voltage or dc current ___.

Last Answer : Regulators.

Description : A receive tty set provides outputs in what formats?

Last Answer : Page-size copy paper and perforated tape.

Description : Outputs of instruction/data path in CU are. a. Reg R/W b. Load/Reg-Reg c. ALU function select d. Load control e. Read control f. IR Latch g. JUMP/Branch/Next PC h_ = All of these

Last Answer : h_ = All of these

Description : What two factors determine the frequency of the output voltage of an alternator?

Last Answer : Speed of rotation and number of poles.

Description : When paralleling two alternators using three synchronizing lamps, the flickering of all three lamps becomes progressively slower and slower. This means the ______________. A. frequency of the incoming ... the bus D. terminal voltage of the incoming alternator is approaching that of the bus

Last Answer : Answer: A

Description : What is the frequency of the output voltage of an alternator with four poles that is rotated at 3600 rpm?

Last Answer : 120 Hz.

Description : What type of prime mover requires a specially designed high-speed alternator?

Last Answer : Steam turbine.

Description : What is the main advantage of the rotating field alternator?

Last Answer : Output voltage is taken directly from the armature (not through brushes or slip rings).

Description : What is the part of an alternator in which the output voltage is generated?

Last Answer : Armature.

Description : A three-phase alternator operates at 450 volts with a power factor of 0.8. If the ammeter indicates 250 amperes, what should be the KW meter reading? A. 90.00 KW B. 127.27 KW C. 155.70 KW D. 194.85 KW

Last Answer : Answer: C

Description : A three-phase alternator is developing 300 amps, with a 0.8 power factor, at 450 volts. The true indicated power on the kilowatt meter, located on the main switchboard, will be ____________. A. 133 kw B. 155 kw C. 187 kw D. 212 kw

Last Answer : Answer: C

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter would then read ____________. A. 181.4 KW B. 186.8 KW C. 194.2 KW D. 201.4 KW

Last Answer : Answer: B

Description : For the illustrated wiring of a three phase alternator, which statement is true about the current? EL-0074 A. phase current is 1.73 times the line current B. line current is 1.73 times the ... . there is no relationship between phase current and line current D. line current is equal to phase current

Last Answer : Answer: D

Description : In the illustrated three phase alternator, line voltage is _________. EL-0074 A. 1.73 times the phase voltage B. equal to the phase voltage C. phase voltage divided by 1.73 D. unable to answer this question without knowing the line current

Last Answer : Answer: A

Description : The output voltage of a three-phase alternator is regulated by the _____________. A. AC voltage to the armature B. AC voltage to the field C. DC voltage to the armature D. DC voltage to the field

Last Answer : Answer: D

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter reading would increase by ___ A. 17.8 KW B. 23.2 KW C. 30.6 KW D. 37.8 KW

Last Answer : Answer: B

Description : The phase sequence of a three-phase alternator will reverse if  A) The field current is reversed keeping the direction of rotation same. B) The field current remains the same but the direction of ... The field current is reversed and also the direction of rotation is reversed D) None of the above

Last Answer : The phase sequence of a three-phase alternator will reverse if The field current remains the same but the direction of rotation is reversed 

Description : What are the excitation methods used in an alternator?*

Last Answer : Rotary : Using rotating diode rectifiers, primary exciter and main exciter. Static : Excitation given by brushes and slip rings.

Description : The connecting rod bolts are tightened up with the initial tension greater than external load so that (A) Failure of bolt will be static (B) The resultant load on bolt will not be affected by ... ) The bolt will not fail by fatigue although the external load is fluctuating (D) All the three

Last Answer : (D) All the three

Description : What do the dotted lines connecting C1, C2, C5, and C6 indicate?

Last Answer : The dotted lines indicate that these capacitors are "ganged" and are tuned together with a single control.

Description : What connecting link is used to transfer energy from a radio transmitter to its antenna located on

Last Answer : Transmission line.

Description : What term is used to identify the procedure of connecting one side of a circuit board with the other?

Last Answer : Interfacial connections.

Description : Why should you always use the highest range when connecting a voltmeter to a circuit?

Last Answer : To prevent excess current through the meter movement.

Description : What are the advantages of connecting ammeters in parallel when performing current measurements?

Last Answer : Decreased internal meter resistance, greater accuracy, and greater current range.

Description : Energy can be inserted or removed from a cavity by what three methods?

Last Answer : Probes, loops, and slots.

Description : What three methods are used to remove protective material?

Last Answer : Chemical, mechanical, and thermal.

Description : Name the three methods of interconnecting components in multilayer printed circuit boards.

Last Answer : Clearance hole, plated-through hole, and layer build-up

Description : What are the three most common methods of interconnections?

Last Answer : Conventional printed circuit boards, multilayer printed circuit boards and modular assemblies.

Description : What are the three most popular methods for encoding digital data onto magnetic disks?

Last Answer : a. Frequency modulation (FM). b. Modified frequency modulation (MFM). c. Run length limited (RLL).

Description : What are three methods for determining if a fuse is open?

Last Answer : Visual inspection, indicators, and using a meter

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A

Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.

Last Answer : Answer: D

Description : If the pointer of the synchroscope is rotating in the slow direction when you are preparing to parallel two alternators, the _____________. A. incoming machine is turning faster than the load alternator B ... alternator is ready to split D. incoming machine is beginning to pick up some of the load

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation of the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. type of alternator

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator

Last Answer : Answer: B

Description : Motorization of an alternator is undesirable because _____________. A. the alternator will be damaged B. it puts an additional load on the bus C. high voltage pulses are induced in the bus D. all of the above

Last Answer : Answer: B

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the ... C. the alternator was operating out of synchronism D. flashover at the alternator collector rings

Last Answer : Answer: C

Description : A circuit breaker for a 300 KW alternator is rated at 470 amperes of full continuous load. The amount of overcurrent allowed is 125%. Which of the following conditions will trip the breaker? A. ... 10 minutes. C. Momentary starting load of 550 amperes. D. Sustained current flow of 590 amperes.

Last Answer : Answer: D