How many voltage outputs are available from a two-phase  three-wire alternator?

1 Answer

Answer :

Three.

Related questions

Description : What are the two methods of connecting the outputs from a three-phase alternator to the load?

Last Answer : Wye and Delta.

Description : Circuits which maintain constant voltage or current outputs are called dc voltage or dc current ___.

Last Answer : Regulators.

Description : In a three-phase alternator, what is the phase relationship between the individual output voltages?

Last Answer : Each phase is displaced 120º from the other two

Description : What two factors determine the frequency of the output voltage of an alternator?

Last Answer : Speed of rotation and number of poles.

Description : When paralleling two alternators using three synchronizing lamps, the flickering of all three lamps becomes progressively slower and slower. This means the ______________. A. frequency of the incoming ... the bus D. terminal voltage of the incoming alternator is approaching that of the bus

Last Answer : Answer: A

Description : What is the frequency of the output voltage of an alternator with four poles that is rotated at 3600 rpm?

Last Answer : 120 Hz.

Description : What is the part of an alternator in which the output voltage is generated?

Last Answer : Armature.

Description : In the illustrated three phase alternator, line voltage is _________. EL-0074 A. 1.73 times the phase voltage B. equal to the phase voltage C. phase voltage divided by 1.73 D. unable to answer this question without knowing the line current

Last Answer : Answer: A

Description : The output voltage of a three-phase alternator is regulated by the _____________. A. AC voltage to the armature B. AC voltage to the field C. DC voltage to the armature D. DC voltage to the field

Last Answer : Answer: D

Description : The frequency of an alternator at a given RPM is determined by the _____________. A. number of turns of wire in the armature coil B. number of magnetic poles C. strength of the magnets used D. output voltage

Last Answer : Answer: B

Description : The frequency output of an operating alternator is controlled by the _____________. A. relative speed of the rotor poles B. number of turns of wire in the armature coil C. strength of the magnets used D. output voltage

Last Answer : Answer: A

Description : One factor that determines the frequency of an alternator is the ____________. A. number of turns of wire in the armature coil B. number of magnetic poles C. strength of the magnets used D. output voltage

Last Answer : Answer: B

Description : If the differential amplifier is configured with a single input and differential outputs, what will the output signals be?

Last Answer : Each output will be a sine wave with a peak-to-peak amplitude of 100 millivolts. The output signals will be 180 degrees out of phase with each other.

Description : How many inputs and outputs are possible with a differential amplifier?

Last Answer : Two inputs, two outputs.

Description : A receive tty set provides outputs in what formats?

Last Answer : Page-size copy paper and perforated tape.

Description : When paralleling two alternators the synchronizing lamps grow dim and are totally darkened as the synchroscope pointer approaches the 0° position. This indicates the ____________. A. alternator voltages ... alternator is in phase with the bus voltage D. synchroscope pointer is defective or broken

Last Answer : Answer: C

Description : Name the various methods for predetermining the voltage regulation of 3-phase Alternator.

Last Answer : The following are the three methods which are used to predetermine the voltage regulation of smooth cylindrical type Alternators · Synchronous impedance / EMF method · Ampere-turn / MMF method · Potier / ZPF method

Description : An alternator has a phase sequence of RYB for its phase voltage. In case the direction of rotation of alternator is reversed, the phase sequence will become?

Last Answer : An alternator has a phase sequence of RYB for its phase voltage. In case the direction of rotation of alternator is reversed, the phase sequence will become RBY.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : An electrical device which employs a stationary armature and a rotating electromagnetic field is used aboard ship as a ____________. A. magnetic amplifier B. ship's service alternator C. three-wire DC generator D. saturable core reactor

Last Answer : Answer: B

Description : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 

Last Answer : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 33%

Description : at the terminal of a three-phase 6.6Kv alternator a load R=200 ohm is connected between two-phase and the third phase is opened. Z1=z2=5 ohm Zo=2 find out the fault current .

Last Answer : 32A

Description : What type of prime mover requires a specially designed high-speed alternator?

Last Answer : Steam turbine.

Description : What is the main advantage of the rotating field alternator?

Last Answer : Output voltage is taken directly from the armature (not through brushes or slip rings).

Description : A three-phase alternator is operating at 450 volts, 250 amps at 0.6 power factor. If the power factor increases to 0.8, the kw load potential will increase by _____________. A. 38.525 kw B. 116.91 kw C. 155.88 kw D. 194.85 kw

Last Answer : Answer: A

Description : A three-phase alternator operates at 450 volts with a power factor of 0.8. If the ammeter indicates 250 amperes, what should be the KW meter reading? A. 90.00 KW B. 127.27 KW C. 155.70 KW D. 194.85 KW

Last Answer : Answer: C

Description : A three-phase alternator is developing 300 amps, with a 0.8 power factor, at 450 volts. The true indicated power on the kilowatt meter, located on the main switchboard, will be ____________. A. 133 kw B. 155 kw C. 187 kw D. 212 kw

Last Answer : Answer: C

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter would then read ____________. A. 181.4 KW B. 186.8 KW C. 194.2 KW D. 201.4 KW

Last Answer : Answer: B

Description : For the illustrated wiring of a three phase alternator, which statement is true about the current? EL-0074 A. phase current is 1.73 times the line current B. line current is 1.73 times the ... . there is no relationship between phase current and line current D. line current is equal to phase current

Last Answer : Answer: D

Description : A three-phase alternator is operating at 450 volts with the switchboard ammeter indicating 300 amps. The kw meter currently indicates 163.6 KW, with a power factor of 0.7. If the power factor increases to 0.8, the KW meter reading would increase by ___ A. 17.8 KW B. 23.2 KW C. 30.6 KW D. 37.8 KW

Last Answer : Answer: B

Description : The phase sequence of a three-phase alternator will reverse if  A) The field current is reversed keeping the direction of rotation same. B) The field current remains the same but the direction of ... The field current is reversed and also the direction of rotation is reversed D) None of the above

Last Answer : The phase sequence of a three-phase alternator will reverse if The field current remains the same but the direction of rotation is reversed 

Description : The battery has following three major functions to perform: a) To provide a source of current for engine starting, lighting and use of horn. b) To help control the voltage in the electrical system. c ... the current produced by dynamo/alternator and to furnish the current d) all of the above. Ans. d

Last Answer : ans d

Description : What wire on goes wher on alternator on 4.3 CHEV?

Last Answer : Need answer

Description : What is the phase relationship between current and voltage in an inductor?

Last Answer : Current lags voltage by 90° (ELI).

Description : Name two of the three described uses of a two-wire open line.

Last Answer : Power lines, rural telephone lines, and telegraph lines

Description : When paralleling two alternators, the synchronizing lamps remain lit as the synchroscope pointer approaches the 0°. This indicates the _____________. A. incoming alternator is running too fast B. alternator ... apart C. synchroscope is defective or broken D. alternator power factors are in phase

Last Answer : Answer: C

Description : Which of the following problems will occur if the circuit breaker of the incoming alternator is closed and it is 180° out of phase with the loaded alternator when paralleling? A. The rotor of the ... The rotor of the incoming alternator will stop. D. Both alternators will parallel 180° out of phase.

Last Answer : Answer: B

Description : Explain negative phase sequence protection of alternator.

Last Answer : Negative phase sequence protection of alternator: Unbalanced loading on alternator mainly causes the negative sequence currents which generate the negative sequence components of magnetic fields. These fields ... components due to unbalance and operates the relay which further operates CB.

Description : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, j0.1 and j0.04 respectively. The neutral of ... the fault is  (A) 513.8 V (B) 889.9 V (C) 1112.0 V (D) 642.2 V

Last Answer : A 20-MVA, 6.6-kV, 3-phase alternator is connected to a 3-phase transmission line. The per unit positive-sequence, negative-sequence and zero-sequence impedances of the alternator are j0.1, ... line. The voltage of the alternator neutral with respect to ground during the fault is 642.2 V

Description : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is :  (A) capacitive (B) inductive (C) resistive (D) inductive and resistive

Last Answer : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is : capacitive 

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description : During 3-phase short circuit on a unloaded alternator, the dc component may be zero in (1) One phase only (2) Any two phases (3) All three phases (4) None of the above 

Last Answer : 1

Description : A full adder logic circuit will have (A) Two inputs and one output. (B) Three inputs and three outputs. (C) Two inputs and two outputs. (D) Three inputs and two outputs.

Last Answer : Ans: D A full adder circuit will add two bits and it will also accounts the carry input generated in the previous stage. Thus three inputs and two outputs (Sum and Carry) are there.

Description : The three outputs x1x2x3 from the 8x3 priority encoder are used to provide a vector address of the form 101x1x2x300. What is the second highest priority vector address in hexadecimal if the vector addresses are starting from the one with the highest priority? (A) BC (B) A4 (C) BD (D) AC

Last Answer : Answer: B

Description : Motorization of an alternator is undesirable because _____________. A. the alternator will be damaged B. it puts an additional load on the bus C. high voltage pulses are induced in the bus D. all of the above

Last Answer : Answer: B

Description : Which of the following actions must be carried out prior to closing the alternator circuit breaker according to the graph shown in the illustration? EL-0002 A. Increase the alternator voltage. B. Decrease the line voltage. C. Increase the line voltage. D. Decrease the line frequency.

Last Answer : Answer: A

Description : An open occurring within the field rheostat of an AC generator can be detected by short circuiting its terminals and observing a ____________. A. negative deflection of the wattmeter pointer B. ... of the wattmeter pointer C. buildup of alternator voltage D. low, but constant alternator voltage

Last Answer : Answer: C

Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure

Last Answer : Answer: D