What term is used to identify the procedure of connecting  one side of a circuit board with the other?

1 Answer

Answer :

Interfacial connections.

Related questions

Description : Why should you always use the highest range when connecting a voltmeter to a circuit?

Last Answer : To prevent excess current through the meter movement.

Description : Multilayer printed circuit board repair is the responsibility of what 2M repair technician?

Last Answer : Microminiature repair technician.

Description : When does most printed circuit board damage occur?

Last Answer : During disassembly or repair.

Description : What term is used to identify each of the many field configurations that can exist in waveguides?

Last Answer : Mode of operation.

Description : What term is used to identify the forward progress velocity of wavefronts in a waveguide?

Last Answer : Group velocity.

Description : What is the term used to identify the amount of field strength required to cause the electrons to just miss the plate and return to the filament in a circular orbit?

Last Answer : The critical value of field strength

Description : What is the term used to identify the points of minimum current and minimum voltage on an antenna?

Last Answer : Current and voltage nodes.

Description : What is the term used to identify the points of high current and high voltage on an antenna?

Last Answer : Current and voltage loops.

Description : What do the dotted lines connecting C1, C2, C5, and C6 indicate?

Last Answer : The dotted lines indicate that these capacitors are "ganged" and are tuned together with a single control.

Description : What connecting link is used to transfer energy from a radio transmitter to its antenna located on

Last Answer : Transmission line.

Description : What are the advantages of connecting ammeters in parallel when performing current measurements?

Last Answer : Decreased internal meter resistance, greater accuracy, and greater current range.

Description : What are the two methods of connecting the outputs from a three-phase alternator to the load?

Last Answer : Wye and Delta.

Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield

Last Answer : Answer: B

Description : Identify the properties of material used for connecting rod with justification

Last Answer : Answer:  1. There are some materials that are commonly used in connecting rods such as alloys of steel, aluminum and titanium. Mostly connecting rods are made by forged steel. It is widely use ... times lighter than carbon steel. It is because density of Al360 is very less compared to carbon steel 

Description : Identify & explain any two difficulties faced while connecting WPP to the power grid.

Last Answer : Difficulties Faced while Connecting WPP to Power Grid: There are several technical issues associated with grid connected systems like power quality issues, power and voltage fluctuations, storage, protection ... that is out of phase with grid voltage and so provide power factor correction.

Description : What are two disadvantages of procedure oriented languages?

Last Answer : They require more space in memory and they process data at a slower rate than symbolic languages.

Description : What led to the development of procedure oriented languages?

Last Answer : The development of mnemonic techniques and macroinstructions.

Description : What procedure should you use when a power input to your equipment is missing?

Last Answer : Work backwards from the load to the source.

Description : Damaged or missing termination pads are replaced using what procedure?

Last Answer : Epoxy a replacement pad to the board, set an eyelet, and solder it.

Description : What procedure involves the use of finely braided copper wire to remove solder?

Last Answer : Wicking.

Description : Name the procedure used to reduce excessive arcing in a magnetron?

Last Answer : Baking in.

Description : What is the procedure for using a megger to check the insulation of a conductor?

Last Answer : Connect one lead to the insulation and one lead to the conductor. Turn the handcrank until it starts to slip. Note the reading

Description : What term is used to describe the frequency at which the filter circuit changes from the point of rejecting the unwanted frequencies to the point of passing the desired frequencies?

Last Answer : Frequency cutoff (fco).

Description : What is the term for the number of times per second that tank circuit energy is either stored in the inductor or capacitor?

Last Answer : Natural frequency or resonant frequency (f r).

Description : In an a.c. circuit that contains both an inductor and a capacitor, what term is used for the difference between the individual reactances?

Last Answer : Resultant reactance.

Description : What term is given to total opposition to ac in a circuit?

Last Answer : Impedance

Description : What term identifies a single resistor that represents total resistance of a complex circuit?

Last Answer : Equivalent resistor or Req.

Description : a. Define the term "working voltage" of a capacitor. b. What should be the working voltage of a capacitor in a circuit that is operating at 600 volts?

Last Answer : a. It is the maximum voltage the capacitor can work without risk of damage. b. 900 volts.

Description : How is board damage caused by technicians?

Last Answer : Repairs by untrained personnel and technicians using improper tools.

Description : How do you prevent excessive heat buildup on an area of a board when soldering multilead components?

Last Answer : Use a skipping pattern

Description : When a lead is soldered to a pad without passing through the board, it is known as what type of termination?

Last Answer : On-the-board termination.

Description : Modules or submodules attached to a mother board are what packaging level?

Last Answer : Level I.

Description : List five precautions to take when installing fiber optic systems on board naval ships.

Last Answer : a. Never bend an optical fiber or cable at a radius of curvature less than the minimum bend radius. b. Never pull fiber optic cables tight or fasten them over or through sharp corners or ... the hardware. e. Allow only trained, authorized personnel to install or repair fiber optic systems.

Description : Which of the following steps would you consider first for an effective communication? (a) Select the channel of communication (b) Plan the evaluation procedure (c) Specify the objectives of communication (d) Identify various media of communication

Last Answer : (c) Specify the objectives of communication

Description : The device in figure 'B' shown in the illustration can be used to control an AC load yet maintain its high gain by ______________. EL-0091 A. connecting the load to the output side of the ... connecting the load to the input side of the bridge D. reversing the current flow through the bias winding

Last Answer : Answer: C

Description : An open shunt field in a direct current machine may be located by connecting the field circuit to an external power source, equal to the rated field voltage or less, and tested with a voltmeter from ... C. any suitable ground to any available line lead D. any field pole to each field coil lead

Last Answer : Answer: A

Description : The proper method of connecting an ammeter in a circuit is demonstrated by which of the diagrams shown in the illustration? EL-0041 A. A B. B C. C D. All of the above

Last Answer : Answer: D

Description : A special service circuit connecting two private branch exchanges (PBX). A. Phantom line B. Private line C. Tie trunk D. Tandem trunk

Last Answer : C. Tie trunk

Description : The local loop of the telephone system is understood to be A. a single piece of wire connecting the subscriber's telephone set to another telephone set in an adjacent room B. a two-wire or four- ... a facsimile machine to a computer D. a group of wires connecting a telephone set to a modem

Last Answer : B. a two-wire or four-wire communication circuit between the customer’s premise and central office

Description : Which one of the following is the advantage of connecting two dry cells in parallel instead of in series? Is it because the parallel arrangement: w) gives twice the EMF of one dry cell x) has no ... circuit half as fast as would a single cell z) has half the internal resistance of a single cell

Last Answer : ANSWER: Z -- HAS HALF THE INTERNAL RESISTANCE OF A SINGLE CELL 

Description : Mention the precautions to be taken while connecting CT and PT in the circuit. 

Last Answer : Precautions to be taken while using instrument transformers: 1. Secondary of CT is never kept open circuited when it is energized. 2. Secondary of PT is never kept short circuited when it ... of the instrument transformers unless they are properly grounded. 8. Never connect to DC circuits.

Description : The purpose of connecting a capacitor in fluorescent tube circuit is • To increase switching on time • To decrease switching off time • To increase power factor • To decrease power consumption

Last Answer : The purpose of connecting a capacitor in fluorescent tube circuit is To increase power factor

Last Answer :  What should be observed when connecting a voltmeter into a DC circuit? A.  rms B.  resistance C.  polarity D.  power factor

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Last Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Description : What system is currently used by all branches of the military to identify test equipment?

Last Answer : Joint Electronics Type Designation System (JETDS).

Description : What type of electrical diagram is used to identify the components of a system?

Last Answer : A pictorial diagram.

Description : What does the cable number identify?

Last Answer : ndividual cable in a specific circuit.

Description : Optical fibers or cables should never be bent at a radius of curvature smaller than a certain value. Identify this radius of curvature

Last Answer : Minimum bend radius.