A commercial power supply has a voltage regulation of: 

1. 1% 2.5% 3.20% 4.50% 

1 Answer

Answer :

A commercial power supply has a voltage regulation of: 1%

Related questions

Description : A resistor placed in parallel to the output of a power supply _____________. A. is a temperature compensator B. corrects power factor C. prevents excessive currents D. aids in output voltage regulation

Last Answer : Answer: D

Description : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: (A) 4.5% (B) less than 4.5% (C) more than 4.5% (D) none of the above

Last Answer : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: more than 4.5%

Description : If a power supply produces 20 volts with no load and 15 volts under full load, what is the percent of regulation?

Last Answer : 33.33%

Description : If the no load voltage of a certain generator is 220V and the rated load voltage is 200V, then the voltage regulation is: a. 1% b. 10% c. 20V d. 9%

Last Answer : If the no load voltage of a certain generator is 220V and the rated load voltage is 200V, then the voltage regulation is: a. 1% b. 10% c. 20V d. 9%

Description : Percentage voltage regulation = _______________________ x 100 ; (Where VNL=No Load Voltage, VFL=Full Load Voltage)

Last Answer : Percentage voltage regulation = _______________________ x 100 ; (Where VNL=No Load Voltage, VFL=Full Load Voltage) (VNL-VFL)/VFL or (VNL-VFL )/VNL

Description : A transformer has negative voltage regulation when its load power factor is- (a) Zero (b) Unity (c) Leading (d) Lagging

Last Answer : Ans: C

Description : Define the percentage voltage regulation and efficiency of a power transformer.  

Last Answer : Voltage regulation is the difference between no load voltage and full load voltage by no load voltage. Voltage regulation = No load voltage - Full load voltage / No load voltage. Voltage regulation is mentioned ... . % Efficiency = Output in watts * 100 / Output in watts + losses. 

Description : Load regulation is a measure of a power supplies ability keep a constant output under conditions of changing A) Line voltage B) Current demand C) Temperature D) Oscillator frequency.

Last Answer : A) Line voltage

Description : 51 A transformer has negative voltage regulation when its load power factor is A. Zero B. Unity C. Leading D. Lagging

Last Answer : C. leading

Description : A two-winding single phase transformer has a voltage regulation of 4.5% at full-load and unity power-factor. At full-load and 0.80 power-factor lagging load the voltage regulation will be (A) 4.5%. (B) less than 4.5%. (C) more than 4.5%. (D) 4.5% or more than 4.5%.

Last Answer : (C) more than 4.5%.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Last Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : Minimum voltage regulation occurs when the power factor of the load is?

Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Description : Which allows banks and other financial institution to auction residential or commercial properties to recover loans? A. Industrial Disputes Act 1947 B. Foreign Exchange Management Act, 1999 C. Banking Regulation Act, 1949 D. SARFAESI Act, 2002 E. None of the Above

Last Answer : D. SARFAESI Act, 2002 Explanation: The Securitisation and Reconstruction of Financial Assets and Enforcement of Security Interest Act, 2002 (also known as the SARFAESI Act) is an ... allows banks and other financial institution to auction residential or commercial properties to recover loans.

Description : Which statute governs external commercial borrowing? e) Foreign Exchange Maximization Act, 1972 f) Foreign Exchange Management Act, 1999 g) Foreign Exchange Minimization Act, 2004 h) Foreign Exchange Regulation Act, 1972

Last Answer : f) Foreign Exchange Management Act, 1999

Description : Water regulation require that cold water supply pipe from the cwsc to tap outlets and the hot water storage vessel be isolated, with what?

Last Answer : I found it out its a Full bore gate valve

Description : Two alternators rated are 200 KW at 4% regulation, 400 KW 5% regulation operating in parallel at 50HZ , when supply 600 KW the new frequency is a) 50 b) 49 c) 51.3 d) 47.7

Last Answer : Ans: 47.7

Last Answer : Req= (1/1200 +1/560 + 1/2.1)^-1        = 2.1 ohms RT= 2.1 + 7.8      = 9.9 ohms IT = V/R = 24/9.9                = 2.4 A Veq= R I =  2.1 2 ... 7.8         = 12.096 w                 = 44.928 w _________________________________________ By: Ellis-Junior Kamatjipose [email protected]

Description : …Hi,  When we supply the microcontroller we use  12V step down transformer> rectifier> filter> 5V voltage regulator. Why not use? 5V transformer> rectifier>filter only. And what voltage regulator will do in our microcontroller?

Last Answer : The powering supply voltage to a microcontroller is 5v if you use a 5v transformer if there is loss of power your output voltage will be drop in the rectifier and there will be change in voltage these can be overcome using a regulator it will give a constant output

Description : What is Voltage Regulation ?

Last Answer : Answer : Voltage regulation is the difference between the voltage at the receiving end of a transmission line when it is unloaded and reloaded.

Description : Why is it important to know voltage regulation ?

Last Answer : Knowing the voltage regulation, the voltage at the load end can be kept within the specified range by the line voltage control devices.

Description : Which of the following statements is true regarding the illustrated circuit? El-0069 A. This full wave bridge should never be used aboard ship because the ground on lead 'A' will show on ... be direct current suitable for electronic circuits requiring voltage regulation. D. All the above are true.

Last Answer : Answer: B

Description : The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ____________. A. droop B. drop C. dip D. regulation

Last Answer : Answer: C

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : Why is the MMF method of estimating the voltage regulation considered as the optimistic method?

Last Answer : In this method the actual value is more than the result obtained.

Description : What are the test data required for predetermining the voltage regulation of an Alternator by MMF method?

Last Answer : Data required for MMF method are : · Effective resistance per phase of the 3-phase winding R · Open circuit characteristic (OCC) at rated speed/frequency · Short circuit characteristic (SCC) at rated speed/frequency

Description : Why is the synchronous impedance method of estimating voltage regulation considered as pessimistic method?

Last Answer : Compared to other methods, the value of voltage regulation obtained by the synchronous impedance method is always higher than the actual valuei.e actual value is lower than the results obtained and therefore this method is called the pessimistic method.

Description : What are the advantages and disadvantages of estimating the voltage regulation of an Alternator by EMF method?

Last Answer : Advantages: · Simple no load tests (for obtaining OCC and SCC) are to be conducted · Calculation procedure is much simpler Disadvantages: · The value of voltage regulation obtained by this method is always higher than the actual value

Description : Name the various methods for predetermining the voltage regulation of 3-phase Alternator.

Last Answer : The following are the three methods which are used to predetermine the voltage regulation of smooth cylindrical type Alternators · Synchronous impedance / EMF method · Ampere-turn / MMF method · Potier / ZPF method

Description : What is the necessity for predetermination of voltage regulation?

Last Answer : Most of the Alternators are manufactured with large power rating , hundreds of kW or MW, and also with large voltage rating upto 33kV. For Alternators of such power and voltage ratings ... performance like voltage regulation then can be predetermined at any desired load currents and power factors.

Description : Define the term voltage regulation of Alternator.

Last Answer : The voltage regulation of an Alternator is defined as the change in terminal voltage from no-load to load condition expressed as a fraction or percentage of terminal voltage at load condition ; the speed and excitation conditions remaining same.

Description : What are the necessary tests to determine the efficiency, voltage regulation, and temperature rise of winding & insulation of transformer?

Last Answer : 1.Direct loading test 2.Open circuit test 3. Short circuit test 4. Sumpner's or back to back test

Description : What are the factors affecting voltage regulation?

Last Answer : Load current Equivalent resistance Equivalent reactance power factor

Description : What is the condition for maximum voltage regulation?

Last Answer : It occurs when load is inductive and power factor is lagging.

Description : What is the condition for zero voltage regulation?

Last Answer : Negative sign indicates zero voltage regulation. It occurs when load is capacitive and power factor is leading.

Description : In a transformer the voltage regulation will be zero when it operates at (A) unity p.f. (B) leading p.f. (C) lagging p.f. (D) zero p.f. leading.

Last Answer : (B) leading p.f.

Description : Define: (i) Efficiency (ii) Voltage regulation of transformer.

Last Answer : i) Efficiency : It is the ratio of output power to the input power of the transformer.It is denoted by η. ii) Voltage Regulation of transformer: The ratio of the change in Secondary Terminal ... So where, VNL = No Load Secondary voltage VFL = Full load secondary voltage

Description : State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation

Last Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Description : The diode oftenly used for voltage regulation in electronic circuits is (a) Zener (b) Varactor (c) Silicon (d) Germanium

Last Answer : The diode oftenly used for voltage regulation in electronic circuits is  Zener.

Description : In a transformer the voltage regulation will be zero when it operates at (A) unity p.f. (B) leading p.f. (C) lagging p.f. D) zero p.f. leading.

Last Answer : In a transformer the voltage regulation will be zero when it operates at leading p.f.

Description : In a transformer, zero voltage regulation at full load is   (a)Not possible   (b) Possible at unity power factor load   (c) Possible at leading power factor load   (d) Possible at lagging power factor load

Last Answer : In a transformer, zero voltage regulation at full load is Possible at leading power factor load 

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Description : The voltage regulation of an alternator having 0.75 leading p.f. load, no-load induced e.m.f. of 2400V and rated terminal voltage of 3000V is —————————————  A) 20% B) —20% C) 150 D) -26.7

Last Answer : -20

Last Answer : The voltage regulation in magnetic amplifier type voltage regulator is effected by varying the reactance.

Description : Negative voltage regulation is indicative that the load is?

Last Answer : Negative voltage regulation is indicative that the load is capacitive.

Description : A good voltage regulation of a transformer means?

Last Answer : A good voltage regulation of a transformer means output voltage fluctuation from no load to full load is least.

Description : Classify hydro-electric power plants according to water flow regulation and explain in brief.

Last Answer : Classification of hydro-electric power plants according to water flow regulation of water flow:-  1. Large reservoir power plant 2. Run-off river (ROR) power plant with poundage 3. Run-off River ... depends upon rate of flow of water Initial cost is less Its purpose is to generate electricity.

Description : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is

Last Answer : For a short transmission line with r/x ratio of is 1.0, the regulation will be zero when the load power factor is 0.707 lead

Last Answer : Supply Voltage Rejection Ratio: It is defined as the ratio of change of input offset voltage to the change in one supply voltage while keeping other supply voltage constant. Ideally, SVRR=0 Output ... that an OPAMP can produce. Since the quiescent output is ideally zero, the ac output voltage

Description : State the following, 1) Position of head light 2) Supply voltage for flasher light 3) Colours used for marker light 4) Frequencies for engine horn. 

Last Answer : Ans: 1) Position of head light: Head light is located at center near roof level. 2) Supply voltage for flasher light: Nominal 110 V. dc, range 70 V to 140 V. 3) Colours used for marker light: ... indicates parking light 4) Frequencies for engine horn: For HT horn - 660 Hz For LT horn - 330 Hz