In a transformer the voltage regulation will be zero when it operates at
(A) unity p.f. (B) leading p.f.
 (C) lagging p.f. (D) zero p.f. leading.

1 Answer

Answer :

(B) leading p.f.

Related questions

Description : A transformer has negative voltage regulation when its load power factor is- (a) Zero (b) Unity (c) Leading (d) Lagging

Last Answer : Ans: C

Description : 51 A transformer has negative voltage regulation when its load power factor is A. Zero B. Unity C. Leading D. Lagging

Last Answer : C. leading

Description : A two-winding single phase transformer has a voltage regulation of 4.5% at full-load and unity power-factor. At full-load and 0.80 power-factor lagging load the voltage regulation will be (A) 4.5%. (B) less than 4.5%. (C) more than 4.5%. (D) 4.5% or more than 4.5%.

Last Answer : (C) more than 4.5%.

Description : When the voltage and the current developed in an AC circuit reach their peak values at the same time, the power factor is considered to be _____________. A. lagging B. leading C. unity D. infinity

Last Answer : Answer: C

Description : The power factor of industrial loads is generally (a) unity (b) lagging (c) leading (d) zero

Last Answer : (b) lagging

Description : A synchronous motor is operating on no-load at unity power factor. If the field current is increased, power factor will become (A) Leading & current will decrease (B) Lagging & current will increase. (C) Lagging & current will decrease. (D) Leading & current will increase.

Last Answer : Ans: A Initially synchronous motor is operating at no load and unity power factor. When field current increases, the excitation will increase. Therefore, p.f will be leading and current will be I CosΦ < I

Description : In a transformer the voltage regulation will be zero when it operates at (A) unity p.f. (B) leading p.f. (C) lagging p.f. D) zero p.f. leading.

Last Answer : In a transformer the voltage regulation will be zero when it operates at leading p.f.

Description : The voltage regulation of an alternator having 0.75 leading p.f. load, no-load induced e.m.f. of 2400V and rated terminal voltage of 3000V is —————————————  A) 20% B) —20% C) 150 D) -26.7

Last Answer : -20

Description : When is the power factor lagging , leading , unity ?

Last Answer : Power factor lagging in inductive load. Power factor leading in capacitive load is power factor unity in resistive load.

Description : When voltage and current developed in an AC circuit reach their peak values at the same time, the power factor is _____________. A. lagging B. leading C. maximum D. minimum

Last Answer : Answer: C

Description : An alternator is delivering rated current at rated voltage and 0.8 power-factor lagging case. If it is required to deliver rated current at rated voltage and 0.8 power-factor leading, the required excitation will be (A) less. (B) more. (C) more or less. (D) the same.

Last Answer : Ans: B Over excitation gives leading power factor and under excitation gives lagging p.f .

Description : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: (A) 4.5% (B) less than 4.5% (C) more than 4.5% (D) none of the above

Last Answer : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: more than 4.5%

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : $ The enzymes which joins short pieces DNA in the laggins strand is called ligase. ! Lagging strand and leading strand are formed due to replication f

Last Answer : $ The enzymes which joins short pieces DNA in the laggins strand is called ligase. ! Lagging strand and ... wrong D. If both As and R are wrong.

Description : What will be the efficiency when the transformer operates at unity power factor and 60% of full load 

Last Answer : What will be the efficiency when the transformer operates at unity power factor and 60% of full load 96.5%

Description : The arc voltage produced in A.C. circuit breaker is always (a) in phase with the arc current (b) lagging the arc current by 90" (c) leading the arc current by 90° (d) none of the above

Last Answer : (a) in phase with the arc current

Description : Explain lagging quantity and leading quantity, explain this concept with voltage and current waveform

Last Answer : When two alternating quantities attain their respective zero or peak values simultaneously, the quantities are said to be in-phase quantities. When the quantities do not attain their respective zero or ... current is leading the voltage or the voltage is said to be lagging behind the current.

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : If the excitation is increased to one of two alternators operating in parallel, the _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. kilowatt load will be greatly increased D. ampere load will be greatly decreased

Last Answer : Answer: A

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation of the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. type of alternator

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator

Last Answer : Answer: B

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : In a transformer, zero voltage regulation at full load is   (a)Not possible   (b) Possible at unity power factor load   (c) Possible at leading power factor load   (d) Possible at lagging power factor load

Last Answer : In a transformer, zero voltage regulation at full load is Possible at leading power factor load 

Description : What are the necessary tests to determine the efficiency, voltage regulation, and temperature rise of winding & insulation of transformer?

Last Answer : 1.Direct loading test 2.Open circuit test 3. Short circuit test 4. Sumpner's or back to back test

Description : Define the percentage voltage regulation and efficiency of a power transformer.  

Last Answer : Voltage regulation is the difference between no load voltage and full load voltage by no load voltage. Voltage regulation = No load voltage - Full load voltage / No load voltage. Voltage regulation is mentioned ... . % Efficiency = Output in watts * 100 / Output in watts + losses. 

Description : A synchronous motor operates at 0.8 pf lagging. If the field current of the motor is continuously increased  1. The power factor decreases upto a certain value of field current and thereafter it increases.  2. The armature current ... the correct answer is (a) 1, 2 (b) 3, 4 (c) 1, 3 (d) 2, 4

Last Answer : A synchronous motor operates at 0.8 pf lagging. If the field current of the motor is continuously increased  1. The power factor decreases upto a certain value of field current and thereafter it increases.  2. The armature current ... the correct answer is (a) 1, 2 (b) 3, 4 (c) 1, 3 (d) 2, 4

Description : What is the condition for zero voltage regulation?

Last Answer : Negative sign indicates zero voltage regulation. It occurs when load is capacitive and power factor is leading.

Description : Leading strand and lagging strand differences. -Biology

Last Answer : answer:

Description : During DNA replication, Okazaki fragments are used to elongate (a) the lagging strand towards replication fork (b) the leading strand away from replication fork (c) the lagging strand away from the replication fork (d) the leading strand towards replication fork.

Last Answer : (b) the leading strand away from replication fork

Description : [75] Two transformers are connected in parallel. These transformers do not have equal percentage impedance which results A. Short-circuiting of the secondaries B. Power factor of one of the ... have negligible core losses D. Loading of the transformers not in proportion to their kVA ratings.

Last Answer : D. Loading of the transformers not in proportion to their kVA ratings

Description : During DNA replication, Okazaki fragments are used to elongate: (1) The lagging strand towards replication fork. (2) The leading strand away from replication fork. (3) The lagging strand away from the replication fork. (4) The leading strand towards replication fork.

Last Answer : (3) The lagging strand away from the replication fork.

Description : Explain the concept of lagging and leading phase angle by waveform.

Last Answer : i) Leading phase angle :  When two ac quantities of same frequency do not attain their respective zero or peak values simultaneously, then the quantities are said to be out-of-phase quantities. The ... Similarly, in the second diagram, the voltage is said to be lagging the current by  Φ.

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the:   (A) squirrel cage induction motor (C) synchronous motor (B) wound rotor induction motor (D) DC shunt motor

Last Answer : A motor which can conveniently be operated at lagging as well as leading power factors is the: synchronous motor

Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.

Last Answer : (A) Both eddy current and hysteresis losses decreases.

Description : Why the earthing transformer primary voltage is 16.5 kV rated in main generator even though actual voltage during the E/F is root 3 times less?

Last Answer : The transformer should not saturate during E/F otherwise it will cause ferroresonance with the GT winding capacitance. Dangerous O/V and neutral shifting will occur. During loss of load or field ... saturation. Saturation can also occur due to point on wave of application causing flux doubling. 

Last Answer : A transformer can have regulation closer to zero on leading power factor.

Description : In conversion of 3-phase to 2-phase supply with T connection, the transformation ratio of the teaser will be__ times to that of main transformer: a) 1.732 b) 1.15 c) 0.866 d) Unity

Last Answer : Ans: C

Description : Define: (i) Efficiency (ii) Voltage regulation of transformer.

Last Answer : i) Efficiency : It is the ratio of output power to the input power of the transformer.It is denoted by η. ii) Voltage Regulation of transformer: The ratio of the change in Secondary Terminal ... So where, VNL = No Load Secondary voltage VFL = Full load secondary voltage

Description : State and justify which of the following two transformers is better:  Transformer A = 4% voltage regulation  Transformer B = 6% voltage regulation

Last Answer : Transformer A with 4% voltage regulation is better.  Justification: Voltage regulation refers to the percentage change in secondary voltage when load is changed from no-load to full-load with primary voltage ... 4% voltage regulation, which is less as compared to 6% of transformer B, it is better.

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : A good voltage regulation of a transformer means?

Last Answer : A good voltage regulation of a transformer means output voltage fluctuation from no load to full load is least.

Description : In a transformer, with closed magnetic coupling between primary and secondary __ will improve: a) Efficiency b) All day efficiency c) Regulation d) None of the above

Last Answer : Ans: C

Description : What is Meant by Regulation in a Transformer?

Last Answer : ANSWER: Voltage regulation in transformers is the difference between the no load voltage and the full load voltage. This is usually expressed in terms of percentage. For example: A transformer delivers 100 ... from 2% to 4%, depending on the size and the application for which they are used

Description : What is meant by regulation in a transformer?

Last Answer : A. Voltage regulation in transformers is the difference between the no load voltage and the full load voltage. This is usually expressed in terms of percentage. Example: A Transformer delivers 100 ... The regulation capacity varies depending on the size and the application for which they are used.

Description : What is Meant by Regulation in a Transformer?

Last Answer : Voltage regulation in transformers is the difference between the no load voltage and the full load voltage. This is usually expressed in terms of percentage. For example: A transformer delivers 100 volts ... voltage drop in transformer/ no load voltage of transformer V2>E2 for leading p.f load V2

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : Which of the following statements is true regarding the illustrated circuit? El-0069 A. This full wave bridge should never be used aboard ship because the ground on lead 'A' will show on ... be direct current suitable for electronic circuits requiring voltage regulation. D. All the above are true.

Last Answer : Answer: B

Description : The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ____________. A. droop B. drop C. dip D. regulation

Last Answer : Answer: C