What term applies to the use of two or more generators to  supply a common load?

1 Answer

Answer :

Parallel operation.

Related questions

Description : What term applies to the voltage variation from no-load to full-load conditions and is expressed as a percentage?

Last Answer : Voltage regulation.

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Description : How is a wave defined as it applies to wave propagation?

Last Answer : A wave is a disturbance which moves through a medium

Description : If a power supply produces 20 volts with no load and 15 volts under full load, what is the percent of regulation?

Last Answer : 33.33%

Description : If the load requirement consists of both positive and negative voltages, what technique is used in the voltage divider to supply the loads from a single voltage source?

Last Answer : The ground (reference point) is placed in the proper point in the voltage divider so that positive and negative voltages are supplied

Description : What are the two classifications of wave generators according to their output waveshapes?

Last Answer : Sinusoidal and nonsinusoidal.

Description : What are report program generators used for?

Last Answer : To generate programs to print detail and summary reports of data files.

Description : What is the basic difference between the primaries of ac and dc rate generators?

Last Answer : The method of primary excitation (ac and permanent magnet).

Description : Motors, switches, voltage regulators, generators, etc., are a few examples of emi sources. What type of emi comes from these sources?

Last Answer : Man-made.

Description : Range-marker generators produce pulses based on what radar constant?

Last Answer : The radar mile (12.36 microseconds).

Description : What is the main disadvantage of series generators?

Last Answer : Output voltage varies as the load varies

Description : What are the three classifications of dc generators?

Last Answer : Series-wound, shunt-wound, and compound-wound

Description : Lap windings are used in generators designed for what type of application?

Last Answer : Higher load currents are possible

Description : Why are drum-type armatures preferred over the Gramme ring armature in modern dc generators?

Last Answer : Drum-type armatures are more efficient, because flux lines are cut by both sides of each coil.

Description : Generators convert mechanical motion to electrical energy using what principle?

Last Answer : Magnetic induction

Description : In signal generators, what device is used to regulate the voltage of the output signal?

Last Answer : Attenuator.

Description : Ships’ generators produce 450-volt, three-phase, ac power; however, most equipment uses 117-volt, single-phase power What transformers and connections are used to convert 450- volt, threephase power to 117-volt, single-phase power?

Last Answer : A method of generating oscillations, a method of turning the oscillations on and off (keying), and an antenna to radiate the energy.

Description : At yield point' of a copper wire A. the load hasn't exceeded the elastic limit yet; so, Hooke's law applies B. the load has already exceeded the elastic limit and the material has become ... stage has passed and the wire has snapped already D. Like Brass and Bronze, Copper has no yield poin

Last Answer : the load has already exceeded the elastic limit and the material has become plastic

Description : AC and DC generators are similar in that they _____________. A. both generate alternating voltages B. both rectify the voltage before delivery C. are constructed at the same physical size for the same kilowatt rating D. both supply three-phase power

Last Answer : Answer: A

Description : All the following are associated with hemolytic disease of the newborn except: a. It is one of the most common diseases among Americans. b. It may occur if an Rh (-) female conceives a child who ... antibodies. d. It can be prevented by using rhogam. 16 Which one of the following applies to the

Last Answer : b. It may occur if an Rh (-) female conceives a child who is Rh (+).

Description : Have you ever been in a situation where the term "I was young and needed the money" applies?

Last Answer : no, guess i was lucky

Description : The term "relative humidity" applies to a) the percentage of moisture in the air as compared to the amount of moisture the air can hold at a specific temperature b) the weight of the moisture in the air c) ... of the air d) the amount of moisture in the air e) the amount of humidity in the air

Last Answer : ANSWER : A

Description : The term responsivity as it applies to a light detector is best described as ∙ A. the time required for the signal to go from 10 to 90 percent of maximum amplitude ∙ B. the ratio of the diode ... . the ratio of the input power to output power ∙ D. the ratio of output current to input current

Last Answer : the ratio of the diode output current to the input optical power

Description : The term responsivity as it applies to a light detector is best described as.

Last Answer : the ratio of the diode output current to the input optical power

Description : A vessel is equipped with two ship's service generators. Generator #1 is rated at 900 kw and generator #2 is rated at 600 kw. During parallel operation, with a hotel load of 1,000 kw, what should be the kw load on generator #2? A. 100 kw B. 400 kw C. 500 kw D. 600 kw

Last Answer : Answer: B

Description : Which of the methods listed is used to maintain the division of load between two compound-wound, DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt ... generators are connected in series. D. The equalizer connection parallels the series fields of all machines.

Last Answer : Answer: D

Description : When two generators are on the line and are sharing the load equally, they are said to be operating in _____________. A. frequency B. series C. parallel D. resonance

Last Answer : Answer: C

Description : Two AC generators of the same capacity are operating in parallel. One with a zero speed droop setting and the other with a 5% speed droop. If its capacity is not exceeded, the unit whose ... B. maintain the frequency of the system C. have poor sensitivity characteristics D. have poor power response

Last Answer : Answer: B

Description : If two AC generators have just been placed in parallel, the true power load is initially distributed evenly by _____________. A. a balance coil B. changing field excitation C. adjusting the governor control settings D. a rheostat

Last Answer : Answer: C

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0°. If you close the circuit breaker at this moment _____________. A. the incoming ... hazardous condition will be created by the incoming machine being at a higher frequency than the bus

Last Answer : Answer: C

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : Kilowatt load is divided between two AC generators operating in parallel by _____________. A. adjusting the governor controls B. varying the excitation voltage C. increasing both prime mover speeds simultaneously D. decreasing both prime mover speeds simultaneously

Last Answer : Answer: A

Description : Which of the methods listed is used to maintain equal load sharing between two compound wound DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt field rheostats ... are connected in series. D. The series fields of both generators are connected in parallel.

Last Answer : Answer: D

Description : The load sharing characteristics of two diesel generators operating in parallel are mostly dependent on their governor ____________. A. load limit settings B. idle speed settings C. speed limit settings D. speed droop settings

Last Answer : Answer: D

Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner

Last Answer : Answer: B

Description : Diesel generators #1 and #2 are operating in parallel at near full load capacity. Diesel generator #1 suddenly trips out mechanically due to low lube oil pressure. The reverse power relay functions ... all nonvital circuits. D. Secure alarms, reset reverse power relay, and restart #1 engine.

Last Answer : Answer: C

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : Which is a function of the voltage regulators used with AC generators? A. To cut out generators when they are no longer required. B. To cut in additional generators automatically as ... between generators operating in parallel. D. To divide reactive current between generators operating in parallel.

Last Answer : Answer: D

Description : Modern DC generators are fitted with commutating poles to _____________. A. prevent motorizing B. reduce sparking C. reduce the load on the main poles D. reduce spring pressure on the brushes

Last Answer : Answer: B

Description : List the factors that affect the load sharing in parallel operating generators?

Last Answer : The total active and reactive power delivered to the load, connected across the common bus-bars, are shared among Synchronous generators, operating in parallel, based on the following three factors ... characteristic/input · Excitation level and · Percentage synchronous impedance and its R/X ratio

Description : The frequency of voltage generated, in case of generators, can be increased by (a) using reactors (b) increasing the load (c) adjusting the governor (d) reducing the terminal voltage (e) none of the above

Last Answer : (c) adjusting the governor

Description : In DC generators, armature reaction is produced actually by (A) Its field current. (B) Armature conductors. (C) Field pole winding. (D) Load current in armature.

Last Answer : Ans: D Because load current in armature gives rise to armature mmf which react with main field mmf.

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Last Answer : D.C. generators are installed near the load centres to reduce line losses.

Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.